Objectives: This article aims to evaluate the accuracy of the color-Doppler-based technique to evaluate residual mitral regurgitation post TEER. Background: The evaluation of residual mitral regurgitation (MR) post-mitral transcutaneous edge-to-edge repair (mitral TEER) is a critical determinant in...

Descripción completa

Detalles Bibliográficos
Autores principales: Shekel, Efrat, Shuvy, Mony, Danenberg, Haim, Planer, David, Gilon, Dan, Leibowitz, David, Beeri, Ronen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573124/
https://www.ncbi.nlm.nih.gov/pubmed/37834991
http://dx.doi.org/10.3390/jcm12196347
_version_ 1785120392574140416
author Shekel, Efrat
Shuvy, Mony
Danenberg, Haim
Planer, David
Gilon, Dan
Leibowitz, David
Beeri, Ronen
author_facet Shekel, Efrat
Shuvy, Mony
Danenberg, Haim
Planer, David
Gilon, Dan
Leibowitz, David
Beeri, Ronen
author_sort Shekel, Efrat
collection PubMed
description Objectives: This article aims to evaluate the accuracy of the color-Doppler-based technique to evaluate residual mitral regurgitation post TEER. Background: The evaluation of residual mitral regurgitation (MR) post-mitral transcutaneous edge-to-edge repair (mitral TEER) is a critical determinant in patients’ outcomes. The common methods used today, based on the integration of color flow Doppler parameters, may be misleading because of the multiple jets and high velocities created by the TEER devices. Methods: Patients undergoing TEER at Hadassah hospital were recruited between 2015 and 2019. Post-procedural MR was evaluated using the integrated qualitative approach as recommended by the guidelines. In addition, the MR volume for each patient was calculated by subtracting the forward stroke volume (calculated by multiplying the LVOT area with the velocity time integral of the LVOT systolic flow) from the total stroke volume (calculated by the biplane Simpson method of discs). We compared the two methods for concordance. Results: Overall, 112 cases were enrolled. In 55.4% of cases, the volumetric residual MR was milder than the MR severity assessed by the guidelines’ recommended method. In 25.1%, the MR severity was similar in both methods. In 16.2%, the MR severity was worse when calculated using the volumetric method (p(Value) < 0.001, Kappa(measure of agreement) = 0.053). The lower residual MR degree using the volumetric approach was mostly observed in patients classified as “moderate” by the integrated approach. Conclusions: MR severity after TEER is often overestimated by the guideline-recommended integrative method when compared with a volumetric method. Alternative methods should be considered to assess the MR severity after mitral TEER.
format Online
Article
Text
id pubmed-10573124
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105731242023-10-14 Mitral Regurgitation Severity Assessment after Transcutaneous Edge-to-Edge Mitral Valve Repair: Recommended Integration versus Volumetric Assessment Guidelines Shekel, Efrat Shuvy, Mony Danenberg, Haim Planer, David Gilon, Dan Leibowitz, David Beeri, Ronen J Clin Med Article Objectives: This article aims to evaluate the accuracy of the color-Doppler-based technique to evaluate residual mitral regurgitation post TEER. Background: The evaluation of residual mitral regurgitation (MR) post-mitral transcutaneous edge-to-edge repair (mitral TEER) is a critical determinant in patients’ outcomes. The common methods used today, based on the integration of color flow Doppler parameters, may be misleading because of the multiple jets and high velocities created by the TEER devices. Methods: Patients undergoing TEER at Hadassah hospital were recruited between 2015 and 2019. Post-procedural MR was evaluated using the integrated qualitative approach as recommended by the guidelines. In addition, the MR volume for each patient was calculated by subtracting the forward stroke volume (calculated by multiplying the LVOT area with the velocity time integral of the LVOT systolic flow) from the total stroke volume (calculated by the biplane Simpson method of discs). We compared the two methods for concordance. Results: Overall, 112 cases were enrolled. In 55.4% of cases, the volumetric residual MR was milder than the MR severity assessed by the guidelines’ recommended method. In 25.1%, the MR severity was similar in both methods. In 16.2%, the MR severity was worse when calculated using the volumetric method (p(Value) < 0.001, Kappa(measure of agreement) = 0.053). The lower residual MR degree using the volumetric approach was mostly observed in patients classified as “moderate” by the integrated approach. Conclusions: MR severity after TEER is often overestimated by the guideline-recommended integrative method when compared with a volumetric method. Alternative methods should be considered to assess the MR severity after mitral TEER. MDPI 2023-10-03 /pmc/articles/PMC10573124/ /pubmed/37834991 http://dx.doi.org/10.3390/jcm12196347 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shekel, Efrat
Shuvy, Mony
Danenberg, Haim
Planer, David
Gilon, Dan
Leibowitz, David
Beeri, Ronen
Mitral Regurgitation Severity Assessment after Transcutaneous Edge-to-Edge Mitral Valve Repair: Recommended Integration versus Volumetric Assessment Guidelines
title Mitral Regurgitation Severity Assessment after Transcutaneous Edge-to-Edge Mitral Valve Repair: Recommended Integration versus Volumetric Assessment Guidelines
title_full Mitral Regurgitation Severity Assessment after Transcutaneous Edge-to-Edge Mitral Valve Repair: Recommended Integration versus Volumetric Assessment Guidelines
title_fullStr Mitral Regurgitation Severity Assessment after Transcutaneous Edge-to-Edge Mitral Valve Repair: Recommended Integration versus Volumetric Assessment Guidelines
title_full_unstemmed Mitral Regurgitation Severity Assessment after Transcutaneous Edge-to-Edge Mitral Valve Repair: Recommended Integration versus Volumetric Assessment Guidelines
title_short Mitral Regurgitation Severity Assessment after Transcutaneous Edge-to-Edge Mitral Valve Repair: Recommended Integration versus Volumetric Assessment Guidelines
title_sort mitral regurgitation severity assessment after transcutaneous edge-to-edge mitral valve repair: recommended integration versus volumetric assessment guidelines
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573124/
https://www.ncbi.nlm.nih.gov/pubmed/37834991
http://dx.doi.org/10.3390/jcm12196347
work_keys_str_mv AT shekelefrat mitralregurgitationseverityassessmentaftertranscutaneousedgetoedgemitralvalverepairrecommendedintegrationversusvolumetricassessmentguidelines
AT shuvymony mitralregurgitationseverityassessmentaftertranscutaneousedgetoedgemitralvalverepairrecommendedintegrationversusvolumetricassessmentguidelines
AT danenberghaim mitralregurgitationseverityassessmentaftertranscutaneousedgetoedgemitralvalverepairrecommendedintegrationversusvolumetricassessmentguidelines
AT planerdavid mitralregurgitationseverityassessmentaftertranscutaneousedgetoedgemitralvalverepairrecommendedintegrationversusvolumetricassessmentguidelines
AT gilondan mitralregurgitationseverityassessmentaftertranscutaneousedgetoedgemitralvalverepairrecommendedintegrationversusvolumetricassessmentguidelines
AT leibowitzdavid mitralregurgitationseverityassessmentaftertranscutaneousedgetoedgemitralvalverepairrecommendedintegrationversusvolumetricassessmentguidelines
AT beerironen mitralregurgitationseverityassessmentaftertranscutaneousedgetoedgemitralvalverepairrecommendedintegrationversusvolumetricassessmentguidelines