Cargando…
Transcatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases
Background: Sutureless aortic bioprostheses are increasingly being used to provide shorter cross-clamp time and facilitate minimally invasive aortic valve replacement. As the use of sutureless valves has increased over the past decade, we begin to encounter their degeneration. We describe clinical o...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573422/ https://www.ncbi.nlm.nih.gov/pubmed/37834910 http://dx.doi.org/10.3390/jcm12196265 |
_version_ | 1785120459905302528 |
---|---|
author | Concistrè, Giovanni Gasbarri, Tommaso Ravani, Marcello Al Jabri, Anees Trianni, Giuseppe Bianchi, Giacomo Margaryan, Rafik Chiaramonti, Francesca Murzi, Michele Kallushi, Enkel Varone, Egidio Simeoni, Simone Leone, Alessandro Farneti, Andrea Berti, Sergio Solinas, Marco |
author_facet | Concistrè, Giovanni Gasbarri, Tommaso Ravani, Marcello Al Jabri, Anees Trianni, Giuseppe Bianchi, Giacomo Margaryan, Rafik Chiaramonti, Francesca Murzi, Michele Kallushi, Enkel Varone, Egidio Simeoni, Simone Leone, Alessandro Farneti, Andrea Berti, Sergio Solinas, Marco |
author_sort | Concistrè, Giovanni |
collection | PubMed |
description | Background: Sutureless aortic bioprostheses are increasingly being used to provide shorter cross-clamp time and facilitate minimally invasive aortic valve replacement. As the use of sutureless valves has increased over the past decade, we begin to encounter their degeneration. We describe clinical outcomes and technical aspects in patients with degenerated sutureless Perceval (CorCym, Italy) aortic bioprosthesis treated with valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). Methods: Between March 2011 and March 2023, 1310 patients underwent aortic valve replacement (AVR) with Perceval bioprosthesis implantation. Severe bioprosthesis degeneration treated with VIV-TAVR occurred in 32 patients with a mean of 6.4 ± 1.9 years (range: 2–10 years) after first implantation. Mean EuroSCORE II was 9.5 ± 6.4% (range: 1.9–35.1%). Results: Thirty of thirty-two (94%) VIV-TAVR were performed via transfemoral and two (6%) via transapical approach. Vascular complications occurred in two patients (6%), and mean hospital stay was 4.6 ± 2.4 days. At mean follow-up of 16.7 ± 15.2 months (range: 1–50 months), survival was 100%, and mean transvalvular pressure gradient was 18.7 ± 5.3 mmHg. Conclusion: VIV-TAVR is a useful option for degenerated Perceval and appears safe and effective. This procedure is associated with good clinical results and excellent hemodynamic performance in our largest single-center experience. |
format | Online Article Text |
id | pubmed-10573422 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-105734222023-10-14 Transcatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases Concistrè, Giovanni Gasbarri, Tommaso Ravani, Marcello Al Jabri, Anees Trianni, Giuseppe Bianchi, Giacomo Margaryan, Rafik Chiaramonti, Francesca Murzi, Michele Kallushi, Enkel Varone, Egidio Simeoni, Simone Leone, Alessandro Farneti, Andrea Berti, Sergio Solinas, Marco J Clin Med Article Background: Sutureless aortic bioprostheses are increasingly being used to provide shorter cross-clamp time and facilitate minimally invasive aortic valve replacement. As the use of sutureless valves has increased over the past decade, we begin to encounter their degeneration. We describe clinical outcomes and technical aspects in patients with degenerated sutureless Perceval (CorCym, Italy) aortic bioprosthesis treated with valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). Methods: Between March 2011 and March 2023, 1310 patients underwent aortic valve replacement (AVR) with Perceval bioprosthesis implantation. Severe bioprosthesis degeneration treated with VIV-TAVR occurred in 32 patients with a mean of 6.4 ± 1.9 years (range: 2–10 years) after first implantation. Mean EuroSCORE II was 9.5 ± 6.4% (range: 1.9–35.1%). Results: Thirty of thirty-two (94%) VIV-TAVR were performed via transfemoral and two (6%) via transapical approach. Vascular complications occurred in two patients (6%), and mean hospital stay was 4.6 ± 2.4 days. At mean follow-up of 16.7 ± 15.2 months (range: 1–50 months), survival was 100%, and mean transvalvular pressure gradient was 18.7 ± 5.3 mmHg. Conclusion: VIV-TAVR is a useful option for degenerated Perceval and appears safe and effective. This procedure is associated with good clinical results and excellent hemodynamic performance in our largest single-center experience. MDPI 2023-09-28 /pmc/articles/PMC10573422/ /pubmed/37834910 http://dx.doi.org/10.3390/jcm12196265 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Concistrè, Giovanni Gasbarri, Tommaso Ravani, Marcello Al Jabri, Anees Trianni, Giuseppe Bianchi, Giacomo Margaryan, Rafik Chiaramonti, Francesca Murzi, Michele Kallushi, Enkel Varone, Egidio Simeoni, Simone Leone, Alessandro Farneti, Andrea Berti, Sergio Solinas, Marco Transcatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases |
title | Transcatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases |
title_full | Transcatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases |
title_fullStr | Transcatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases |
title_full_unstemmed | Transcatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases |
title_short | Transcatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases |
title_sort | transcatheter aortic valve replacement in degenerated perceval bioprosthesis: clinical and technical aspects in 32 cases |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573422/ https://www.ncbi.nlm.nih.gov/pubmed/37834910 http://dx.doi.org/10.3390/jcm12196265 |
work_keys_str_mv | AT concistregiovanni transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT gasbarritommaso transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT ravanimarcello transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT aljabrianees transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT triannigiuseppe transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT bianchigiacomo transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT margaryanrafik transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT chiaramontifrancesca transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT murzimichele transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT kallushienkel transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT varoneegidio transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT simeonisimone transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT leonealessandro transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT farnetiandrea transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT bertisergio transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases AT solinasmarco transcatheteraorticvalvereplacementindegeneratedpercevalbioprosthesisclinicalandtechnicalaspectsin32cases |