Cargando…

The Stream Device—A Retrospective Review of 51 Cases

Mechanical thrombectomy is the gold-standard treatment for patients that have suffered large-vessel occlusion (LVO) stroke. Various different stent-retrievers, aspiration catheters, and techniques have been developed to perform this procedure. We present our initial results regarding the Stream devi...

Descripción completa

Detalles Bibliográficos
Autores principales: Kupcs, Karlis, Sproge, Patricija, Kupca, Katrina, Bhogal, Pervinder
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573462/
https://www.ncbi.nlm.nih.gov/pubmed/37835028
http://dx.doi.org/10.3390/jcm12196384
_version_ 1785120469557444608
author Kupcs, Karlis
Sproge, Patricija
Kupca, Katrina
Bhogal, Pervinder
author_facet Kupcs, Karlis
Sproge, Patricija
Kupca, Katrina
Bhogal, Pervinder
author_sort Kupcs, Karlis
collection PubMed
description Mechanical thrombectomy is the gold-standard treatment for patients that have suffered large-vessel occlusion (LVO) stroke. Various different stent-retrievers, aspiration catheters, and techniques have been developed to perform this procedure. We present our initial results regarding the Stream device. Materials and Methods: We performed a retrospective review of a prospectively maintained database at our high-volume centre to identify all patients treated with the Stream device between February 2021 and January 2023. We recorded baseline demographics, NIHSS, ASPECT scores, eTICI scores, complications, and 90-day mRS. Results: We identified 51 patients, 49.0% of whom were male (n = 25), with a median age of 73 (range: 51–89) and a median NIHSS score of 17 (range 4–22), and 68.6% received IV tPA. The median ASPECT score was 10 (range 6–10). Hyperdense clots were seen in 34 cases (66.7%), with a mean clot length of 12 ± 6.2 mm (range 2–26 mm). Clots were located in the anterior circulation in 49 patients. The standard Stream device was used in 78.4% of cases, with Stream 17 being used in 19.6% of cases. The FPE was observed in 25.5% of cases (n = 13), with the mFPE being seen in 31.4% of cases (n = 16). A final eTICI score of ≥2b was achieved in 90.2% of cases (n = 46), and eTICI 2c/3 was seen in 84.3% of cases (n = 43). Furthermore, 24 h CT scans showed that the median ASPECT score was 8 (range 0–10). Good functional outcomes at 90 days (mRS ≤ 2) were achieved in 21.6% of cases (n = 11). Conclusions: The Stream device shows acceptable rates of FPE and mFPE compared to existing devices. Further larger studies are required alongside an understanding of the optimal technique for this device’s use.
format Online
Article
Text
id pubmed-10573462
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105734622023-10-14 The Stream Device—A Retrospective Review of 51 Cases Kupcs, Karlis Sproge, Patricija Kupca, Katrina Bhogal, Pervinder J Clin Med Article Mechanical thrombectomy is the gold-standard treatment for patients that have suffered large-vessel occlusion (LVO) stroke. Various different stent-retrievers, aspiration catheters, and techniques have been developed to perform this procedure. We present our initial results regarding the Stream device. Materials and Methods: We performed a retrospective review of a prospectively maintained database at our high-volume centre to identify all patients treated with the Stream device between February 2021 and January 2023. We recorded baseline demographics, NIHSS, ASPECT scores, eTICI scores, complications, and 90-day mRS. Results: We identified 51 patients, 49.0% of whom were male (n = 25), with a median age of 73 (range: 51–89) and a median NIHSS score of 17 (range 4–22), and 68.6% received IV tPA. The median ASPECT score was 10 (range 6–10). Hyperdense clots were seen in 34 cases (66.7%), with a mean clot length of 12 ± 6.2 mm (range 2–26 mm). Clots were located in the anterior circulation in 49 patients. The standard Stream device was used in 78.4% of cases, with Stream 17 being used in 19.6% of cases. The FPE was observed in 25.5% of cases (n = 13), with the mFPE being seen in 31.4% of cases (n = 16). A final eTICI score of ≥2b was achieved in 90.2% of cases (n = 46), and eTICI 2c/3 was seen in 84.3% of cases (n = 43). Furthermore, 24 h CT scans showed that the median ASPECT score was 8 (range 0–10). Good functional outcomes at 90 days (mRS ≤ 2) were achieved in 21.6% of cases (n = 11). Conclusions: The Stream device shows acceptable rates of FPE and mFPE compared to existing devices. Further larger studies are required alongside an understanding of the optimal technique for this device’s use. MDPI 2023-10-06 /pmc/articles/PMC10573462/ /pubmed/37835028 http://dx.doi.org/10.3390/jcm12196384 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kupcs, Karlis
Sproge, Patricija
Kupca, Katrina
Bhogal, Pervinder
The Stream Device—A Retrospective Review of 51 Cases
title The Stream Device—A Retrospective Review of 51 Cases
title_full The Stream Device—A Retrospective Review of 51 Cases
title_fullStr The Stream Device—A Retrospective Review of 51 Cases
title_full_unstemmed The Stream Device—A Retrospective Review of 51 Cases
title_short The Stream Device—A Retrospective Review of 51 Cases
title_sort stream device—a retrospective review of 51 cases
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573462/
https://www.ncbi.nlm.nih.gov/pubmed/37835028
http://dx.doi.org/10.3390/jcm12196384
work_keys_str_mv AT kupcskarlis thestreamdevicearetrospectivereviewof51cases
AT sprogepatricija thestreamdevicearetrospectivereviewof51cases
AT kupcakatrina thestreamdevicearetrospectivereviewof51cases
AT bhogalpervinder thestreamdevicearetrospectivereviewof51cases
AT kupcskarlis streamdevicearetrospectivereviewof51cases
AT sprogepatricija streamdevicearetrospectivereviewof51cases
AT kupcakatrina streamdevicearetrospectivereviewof51cases
AT bhogalpervinder streamdevicearetrospectivereviewof51cases