Cargando…

Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation

The surface area of encapsulation around the Ahmed glaucoma valve (AGV) endplate is a critical factor in the surgical outcome as it is associated with the degree of IOP reduction. We investigated the surgical outcome of AGV implantation with an additional pericardium graft inserted adjacent to the e...

Descripción completa

Detalles Bibliográficos
Autores principales: Oh, Si Eun, Jung, Kyoung In, Shin, Hee Jong, Ryu, Hee Kyung, Kim, Seong Ah, Park, Hae-Young Lopilly, Park, Chan Kee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573632/
https://www.ncbi.nlm.nih.gov/pubmed/37834909
http://dx.doi.org/10.3390/jcm12196266
_version_ 1785120509745168384
author Oh, Si Eun
Jung, Kyoung In
Shin, Hee Jong
Ryu, Hee Kyung
Kim, Seong Ah
Park, Hae-Young Lopilly
Park, Chan Kee
author_facet Oh, Si Eun
Jung, Kyoung In
Shin, Hee Jong
Ryu, Hee Kyung
Kim, Seong Ah
Park, Hae-Young Lopilly
Park, Chan Kee
author_sort Oh, Si Eun
collection PubMed
description The surface area of encapsulation around the Ahmed glaucoma valve (AGV) endplate is a critical factor in the surgical outcome as it is associated with the degree of IOP reduction. We investigated the surgical outcome of AGV implantation with an additional pericardium graft inserted adjacent to the endplate, with the intent of expanding the surface area of encapsulation. We enrolled 92 patients (92 eyes) who underwent AGV implantation. Of them, 50 patients underwent conventional surgery (termed the without-expansion group), and 42 received an additional an 8 × 6 mm pericardium graft inserted adjacent to the AGV endplate at the sub-Tenon’s space (with-expansion). The hypertensive phase was classified as mild (>21 mmHg), moderate (>25 mmHg), and severe (>30 mmHg). Six months post-surgery, the with-expansion group exhibited a lower IOP (14.90 ± 4.27 mmHg) and lower peak IOP (22.29 ± 4.95 mmHg) than the without-expansion group (17.56 ± 4.88 mmHg and 25.06 ± 6.18 mmHg, p = 0.008 and p = 0.021, respectively). The with-expansion group exhibited a relatively low rate of moderate (16.7%) and severe (4.8%) hypertensive phases compared to the without-expansion group (40.0% and 20.0%, with p = 0.014 and p = 0.031, respectively). The additional pericardium graft was associated with a reduced occurrence of moderate hypertensive phase in both univariate and multivariate analysis logistic regression analyses (p = 0.017 and p = 0.038, respectively). Endplate surface area expansion using an additional pericardium graft reduced the occurrence of moderate and severe hypertensive phases, and lower postoperative 6-month IOP could be achieved.
format Online
Article
Text
id pubmed-10573632
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105736322023-10-14 Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation Oh, Si Eun Jung, Kyoung In Shin, Hee Jong Ryu, Hee Kyung Kim, Seong Ah Park, Hae-Young Lopilly Park, Chan Kee J Clin Med Article The surface area of encapsulation around the Ahmed glaucoma valve (AGV) endplate is a critical factor in the surgical outcome as it is associated with the degree of IOP reduction. We investigated the surgical outcome of AGV implantation with an additional pericardium graft inserted adjacent to the endplate, with the intent of expanding the surface area of encapsulation. We enrolled 92 patients (92 eyes) who underwent AGV implantation. Of them, 50 patients underwent conventional surgery (termed the without-expansion group), and 42 received an additional an 8 × 6 mm pericardium graft inserted adjacent to the AGV endplate at the sub-Tenon’s space (with-expansion). The hypertensive phase was classified as mild (>21 mmHg), moderate (>25 mmHg), and severe (>30 mmHg). Six months post-surgery, the with-expansion group exhibited a lower IOP (14.90 ± 4.27 mmHg) and lower peak IOP (22.29 ± 4.95 mmHg) than the without-expansion group (17.56 ± 4.88 mmHg and 25.06 ± 6.18 mmHg, p = 0.008 and p = 0.021, respectively). The with-expansion group exhibited a relatively low rate of moderate (16.7%) and severe (4.8%) hypertensive phases compared to the without-expansion group (40.0% and 20.0%, with p = 0.014 and p = 0.031, respectively). The additional pericardium graft was associated with a reduced occurrence of moderate hypertensive phase in both univariate and multivariate analysis logistic regression analyses (p = 0.017 and p = 0.038, respectively). Endplate surface area expansion using an additional pericardium graft reduced the occurrence of moderate and severe hypertensive phases, and lower postoperative 6-month IOP could be achieved. MDPI 2023-09-28 /pmc/articles/PMC10573632/ /pubmed/37834909 http://dx.doi.org/10.3390/jcm12196266 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oh, Si Eun
Jung, Kyoung In
Shin, Hee Jong
Ryu, Hee Kyung
Kim, Seong Ah
Park, Hae-Young Lopilly
Park, Chan Kee
Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation
title Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation
title_full Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation
title_fullStr Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation
title_full_unstemmed Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation
title_short Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation
title_sort effect of a pericardium graft inserted adjacent to the endplate in the ahmed glaucoma valve implantation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573632/
https://www.ncbi.nlm.nih.gov/pubmed/37834909
http://dx.doi.org/10.3390/jcm12196266
work_keys_str_mv AT ohsieun effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation
AT jungkyoungin effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation
AT shinheejong effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation
AT ryuheekyung effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation
AT kimseongah effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation
AT parkhaeyounglopilly effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation
AT parkchankee effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation