Cargando…
Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation
The surface area of encapsulation around the Ahmed glaucoma valve (AGV) endplate is a critical factor in the surgical outcome as it is associated with the degree of IOP reduction. We investigated the surgical outcome of AGV implantation with an additional pericardium graft inserted adjacent to the e...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573632/ https://www.ncbi.nlm.nih.gov/pubmed/37834909 http://dx.doi.org/10.3390/jcm12196266 |
_version_ | 1785120509745168384 |
---|---|
author | Oh, Si Eun Jung, Kyoung In Shin, Hee Jong Ryu, Hee Kyung Kim, Seong Ah Park, Hae-Young Lopilly Park, Chan Kee |
author_facet | Oh, Si Eun Jung, Kyoung In Shin, Hee Jong Ryu, Hee Kyung Kim, Seong Ah Park, Hae-Young Lopilly Park, Chan Kee |
author_sort | Oh, Si Eun |
collection | PubMed |
description | The surface area of encapsulation around the Ahmed glaucoma valve (AGV) endplate is a critical factor in the surgical outcome as it is associated with the degree of IOP reduction. We investigated the surgical outcome of AGV implantation with an additional pericardium graft inserted adjacent to the endplate, with the intent of expanding the surface area of encapsulation. We enrolled 92 patients (92 eyes) who underwent AGV implantation. Of them, 50 patients underwent conventional surgery (termed the without-expansion group), and 42 received an additional an 8 × 6 mm pericardium graft inserted adjacent to the AGV endplate at the sub-Tenon’s space (with-expansion). The hypertensive phase was classified as mild (>21 mmHg), moderate (>25 mmHg), and severe (>30 mmHg). Six months post-surgery, the with-expansion group exhibited a lower IOP (14.90 ± 4.27 mmHg) and lower peak IOP (22.29 ± 4.95 mmHg) than the without-expansion group (17.56 ± 4.88 mmHg and 25.06 ± 6.18 mmHg, p = 0.008 and p = 0.021, respectively). The with-expansion group exhibited a relatively low rate of moderate (16.7%) and severe (4.8%) hypertensive phases compared to the without-expansion group (40.0% and 20.0%, with p = 0.014 and p = 0.031, respectively). The additional pericardium graft was associated with a reduced occurrence of moderate hypertensive phase in both univariate and multivariate analysis logistic regression analyses (p = 0.017 and p = 0.038, respectively). Endplate surface area expansion using an additional pericardium graft reduced the occurrence of moderate and severe hypertensive phases, and lower postoperative 6-month IOP could be achieved. |
format | Online Article Text |
id | pubmed-10573632 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-105736322023-10-14 Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation Oh, Si Eun Jung, Kyoung In Shin, Hee Jong Ryu, Hee Kyung Kim, Seong Ah Park, Hae-Young Lopilly Park, Chan Kee J Clin Med Article The surface area of encapsulation around the Ahmed glaucoma valve (AGV) endplate is a critical factor in the surgical outcome as it is associated with the degree of IOP reduction. We investigated the surgical outcome of AGV implantation with an additional pericardium graft inserted adjacent to the endplate, with the intent of expanding the surface area of encapsulation. We enrolled 92 patients (92 eyes) who underwent AGV implantation. Of them, 50 patients underwent conventional surgery (termed the without-expansion group), and 42 received an additional an 8 × 6 mm pericardium graft inserted adjacent to the AGV endplate at the sub-Tenon’s space (with-expansion). The hypertensive phase was classified as mild (>21 mmHg), moderate (>25 mmHg), and severe (>30 mmHg). Six months post-surgery, the with-expansion group exhibited a lower IOP (14.90 ± 4.27 mmHg) and lower peak IOP (22.29 ± 4.95 mmHg) than the without-expansion group (17.56 ± 4.88 mmHg and 25.06 ± 6.18 mmHg, p = 0.008 and p = 0.021, respectively). The with-expansion group exhibited a relatively low rate of moderate (16.7%) and severe (4.8%) hypertensive phases compared to the without-expansion group (40.0% and 20.0%, with p = 0.014 and p = 0.031, respectively). The additional pericardium graft was associated with a reduced occurrence of moderate hypertensive phase in both univariate and multivariate analysis logistic regression analyses (p = 0.017 and p = 0.038, respectively). Endplate surface area expansion using an additional pericardium graft reduced the occurrence of moderate and severe hypertensive phases, and lower postoperative 6-month IOP could be achieved. MDPI 2023-09-28 /pmc/articles/PMC10573632/ /pubmed/37834909 http://dx.doi.org/10.3390/jcm12196266 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Oh, Si Eun Jung, Kyoung In Shin, Hee Jong Ryu, Hee Kyung Kim, Seong Ah Park, Hae-Young Lopilly Park, Chan Kee Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation |
title | Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation |
title_full | Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation |
title_fullStr | Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation |
title_full_unstemmed | Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation |
title_short | Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation |
title_sort | effect of a pericardium graft inserted adjacent to the endplate in the ahmed glaucoma valve implantation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10573632/ https://www.ncbi.nlm.nih.gov/pubmed/37834909 http://dx.doi.org/10.3390/jcm12196266 |
work_keys_str_mv | AT ohsieun effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation AT jungkyoungin effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation AT shinheejong effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation AT ryuheekyung effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation AT kimseongah effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation AT parkhaeyounglopilly effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation AT parkchankee effectofapericardiumgraftinsertedadjacenttotheendplateintheahmedglaucomavalveimplantation |