Cargando…

Development of Adaptive Point-Spread Function Estimation Method in Various Scintillation Detector Thickness for X-ray Imaging

An indirect conversion X-ray detector uses a scintillator that utilizes the proportionality of the intensity of incident radiation to the amount of visible light emitted. A thicker scintillator reduces the patient’s dose while decreasing the sharpness. A thin scintillator has an advantage in terms o...

Descripción completa

Detalles Bibliográficos
Autores principales: Cha, Bo Kyung, Lee, Youngjin, Kim, Kyuseok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10574908/
https://www.ncbi.nlm.nih.gov/pubmed/37837015
http://dx.doi.org/10.3390/s23198185
_version_ 1785120799007440896
author Cha, Bo Kyung
Lee, Youngjin
Kim, Kyuseok
author_facet Cha, Bo Kyung
Lee, Youngjin
Kim, Kyuseok
author_sort Cha, Bo Kyung
collection PubMed
description An indirect conversion X-ray detector uses a scintillator that utilizes the proportionality of the intensity of incident radiation to the amount of visible light emitted. A thicker scintillator reduces the patient’s dose while decreasing the sharpness. A thin scintillator has an advantage in terms of sharpness; however, its noise component increases. Thus, the proposed method converts the spatial resolution of radiographic images acquired from a normal-thickness scintillation detector into a thin-thickness scintillation detector. Note that noise amplification and artifacts were minimized as much as possible after non-blind deconvolution. To accomplish this, the proposed algorithm estimates the optimal point-spread function (PSF) when the structural similarity index (SSIM) and feature similarity index (FSIM) are the most similar between thick and thin scintillator images. Simulation and experimental results demonstrate the viability of the proposed method. Moreover, the deconvolution images obtained using the proposed scheme show an effective image restoration method in terms of the human visible system compared to that of the traditional PSF measurement technique. Consequently, the proposed method is useful for restoring degraded images using the adaptive PSF while preventing noise amplification and artifacts and is effective in improving the image quality in the present X-ray imaging system.
format Online
Article
Text
id pubmed-10574908
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105749082023-10-14 Development of Adaptive Point-Spread Function Estimation Method in Various Scintillation Detector Thickness for X-ray Imaging Cha, Bo Kyung Lee, Youngjin Kim, Kyuseok Sensors (Basel) Article An indirect conversion X-ray detector uses a scintillator that utilizes the proportionality of the intensity of incident radiation to the amount of visible light emitted. A thicker scintillator reduces the patient’s dose while decreasing the sharpness. A thin scintillator has an advantage in terms of sharpness; however, its noise component increases. Thus, the proposed method converts the spatial resolution of radiographic images acquired from a normal-thickness scintillation detector into a thin-thickness scintillation detector. Note that noise amplification and artifacts were minimized as much as possible after non-blind deconvolution. To accomplish this, the proposed algorithm estimates the optimal point-spread function (PSF) when the structural similarity index (SSIM) and feature similarity index (FSIM) are the most similar between thick and thin scintillator images. Simulation and experimental results demonstrate the viability of the proposed method. Moreover, the deconvolution images obtained using the proposed scheme show an effective image restoration method in terms of the human visible system compared to that of the traditional PSF measurement technique. Consequently, the proposed method is useful for restoring degraded images using the adaptive PSF while preventing noise amplification and artifacts and is effective in improving the image quality in the present X-ray imaging system. MDPI 2023-09-30 /pmc/articles/PMC10574908/ /pubmed/37837015 http://dx.doi.org/10.3390/s23198185 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cha, Bo Kyung
Lee, Youngjin
Kim, Kyuseok
Development of Adaptive Point-Spread Function Estimation Method in Various Scintillation Detector Thickness for X-ray Imaging
title Development of Adaptive Point-Spread Function Estimation Method in Various Scintillation Detector Thickness for X-ray Imaging
title_full Development of Adaptive Point-Spread Function Estimation Method in Various Scintillation Detector Thickness for X-ray Imaging
title_fullStr Development of Adaptive Point-Spread Function Estimation Method in Various Scintillation Detector Thickness for X-ray Imaging
title_full_unstemmed Development of Adaptive Point-Spread Function Estimation Method in Various Scintillation Detector Thickness for X-ray Imaging
title_short Development of Adaptive Point-Spread Function Estimation Method in Various Scintillation Detector Thickness for X-ray Imaging
title_sort development of adaptive point-spread function estimation method in various scintillation detector thickness for x-ray imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10574908/
https://www.ncbi.nlm.nih.gov/pubmed/37837015
http://dx.doi.org/10.3390/s23198185
work_keys_str_mv AT chabokyung developmentofadaptivepointspreadfunctionestimationmethodinvariousscintillationdetectorthicknessforxrayimaging
AT leeyoungjin developmentofadaptivepointspreadfunctionestimationmethodinvariousscintillationdetectorthicknessforxrayimaging
AT kimkyuseok developmentofadaptivepointspreadfunctionestimationmethodinvariousscintillationdetectorthicknessforxrayimaging