A Comprehensive Study on Measurement Accuracy of Distributed Fiber Optic Sensors Embedded within Capillaries of Solid Structures

Embedding fiber optic sensors (FOSs) within parts for strain measurement is attracting widespread interest due to its great potential in the field of structural health monitoring (SHM). This work proposes a novel method of embedding FOSs using capillaries within solid structures and investigates fib...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Yuzhe, Rans, Calvin, Zarouchas, Dimitrios, Benedictus, Rinze
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10574909/
https://www.ncbi.nlm.nih.gov/pubmed/37836913
http://dx.doi.org/10.3390/s23198083
_version_ 1785120799247564800
author Xiao, Yuzhe
Rans, Calvin
Zarouchas, Dimitrios
Benedictus, Rinze
author_facet Xiao, Yuzhe
Rans, Calvin
Zarouchas, Dimitrios
Benedictus, Rinze
author_sort Xiao, Yuzhe
collection PubMed
description Embedding fiber optic sensors (FOSs) within parts for strain measurement is attracting widespread interest due to its great potential in the field of structural health monitoring (SHM). This work proposes a novel method of embedding FOSs using capillaries within solid structures and investigates fiber positions and orientation uncertainties within capillaries of different sizes and their influences on strain measurement accuracies. To investigate how the fiber positions and orientation variations influence strain measurement accuracy, both analytical and numerical models are utilized to predict strain distributions along embedded fibers at different positions and with different orientations within the specimen. To verify the predictions, a group of specimens made of Aluminum 6082 was prepared, and the specimens in each group had capillaries of 2 mm, 4 mm, and 6 mm diameters, respectively. Fibers were embedded within each specimen using the capillaries. Four-point bending static tests were conducted for each specimen with embedded FOSs, performing in situ strain measurement. Subsequently, the specimens were partitioned into several pieces, and the cross sections were observed to know the real positions of the embedded fiber. Finally, the strain predictions at the real locations of the fiber were compared with the measured strain from the embedded FOSs. The predicted strain distributions as a function of the fiber positions alone and as a function of both the fiber positions and orientations were compared to assess the influence of fiber orientation change. The results from a combination of analytical, numerical, and experimental techniques suggest that the fiber position from the capillary center is the main factor that can influence strain measurement accuracies of embedded FOSs, and potential fiber misalignments within the capillary had a negligible influence. The fiber position-induced measured error increases from 10.5% to 18.5% as the capillary diameter increases from 2 mm to 6 mm. A 2 mm capillary diameter is able to lead to the lowest measurement error in this study and maintains ease of embedding. In addition, it is found that the measured strain always lies within a strain window defined by the strain distribution along capillary boundaries when there are no cracks. This can be further studied for crack detection.
format Online
Article
Text
id pubmed-10574909
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105749092023-10-14 A Comprehensive Study on Measurement Accuracy of Distributed Fiber Optic Sensors Embedded within Capillaries of Solid Structures Xiao, Yuzhe Rans, Calvin Zarouchas, Dimitrios Benedictus, Rinze Sensors (Basel) Article Embedding fiber optic sensors (FOSs) within parts for strain measurement is attracting widespread interest due to its great potential in the field of structural health monitoring (SHM). This work proposes a novel method of embedding FOSs using capillaries within solid structures and investigates fiber positions and orientation uncertainties within capillaries of different sizes and their influences on strain measurement accuracies. To investigate how the fiber positions and orientation variations influence strain measurement accuracy, both analytical and numerical models are utilized to predict strain distributions along embedded fibers at different positions and with different orientations within the specimen. To verify the predictions, a group of specimens made of Aluminum 6082 was prepared, and the specimens in each group had capillaries of 2 mm, 4 mm, and 6 mm diameters, respectively. Fibers were embedded within each specimen using the capillaries. Four-point bending static tests were conducted for each specimen with embedded FOSs, performing in situ strain measurement. Subsequently, the specimens were partitioned into several pieces, and the cross sections were observed to know the real positions of the embedded fiber. Finally, the strain predictions at the real locations of the fiber were compared with the measured strain from the embedded FOSs. The predicted strain distributions as a function of the fiber positions alone and as a function of both the fiber positions and orientations were compared to assess the influence of fiber orientation change. The results from a combination of analytical, numerical, and experimental techniques suggest that the fiber position from the capillary center is the main factor that can influence strain measurement accuracies of embedded FOSs, and potential fiber misalignments within the capillary had a negligible influence. The fiber position-induced measured error increases from 10.5% to 18.5% as the capillary diameter increases from 2 mm to 6 mm. A 2 mm capillary diameter is able to lead to the lowest measurement error in this study and maintains ease of embedding. In addition, it is found that the measured strain always lies within a strain window defined by the strain distribution along capillary boundaries when there are no cracks. This can be further studied for crack detection. MDPI 2023-09-26 /pmc/articles/PMC10574909/ /pubmed/37836913 http://dx.doi.org/10.3390/s23198083 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Xiao, Yuzhe
Rans, Calvin
Zarouchas, Dimitrios
Benedictus, Rinze
A Comprehensive Study on Measurement Accuracy of Distributed Fiber Optic Sensors Embedded within Capillaries of Solid Structures
title A Comprehensive Study on Measurement Accuracy of Distributed Fiber Optic Sensors Embedded within Capillaries of Solid Structures
title_full A Comprehensive Study on Measurement Accuracy of Distributed Fiber Optic Sensors Embedded within Capillaries of Solid Structures
title_fullStr A Comprehensive Study on Measurement Accuracy of Distributed Fiber Optic Sensors Embedded within Capillaries of Solid Structures
title_full_unstemmed A Comprehensive Study on Measurement Accuracy of Distributed Fiber Optic Sensors Embedded within Capillaries of Solid Structures
title_short A Comprehensive Study on Measurement Accuracy of Distributed Fiber Optic Sensors Embedded within Capillaries of Solid Structures
title_sort comprehensive study on measurement accuracy of distributed fiber optic sensors embedded within capillaries of solid structures
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10574909/
https://www.ncbi.nlm.nih.gov/pubmed/37836913
http://dx.doi.org/10.3390/s23198083
work_keys_str_mv AT xiaoyuzhe acomprehensivestudyonmeasurementaccuracyofdistributedfiberopticsensorsembeddedwithincapillariesofsolidstructures
AT ranscalvin acomprehensivestudyonmeasurementaccuracyofdistributedfiberopticsensorsembeddedwithincapillariesofsolidstructures
AT zarouchasdimitrios acomprehensivestudyonmeasurementaccuracyofdistributedfiberopticsensorsembeddedwithincapillariesofsolidstructures
AT benedictusrinze acomprehensivestudyonmeasurementaccuracyofdistributedfiberopticsensorsembeddedwithincapillariesofsolidstructures
AT xiaoyuzhe comprehensivestudyonmeasurementaccuracyofdistributedfiberopticsensorsembeddedwithincapillariesofsolidstructures
AT ranscalvin comprehensivestudyonmeasurementaccuracyofdistributedfiberopticsensorsembeddedwithincapillariesofsolidstructures
AT zarouchasdimitrios comprehensivestudyonmeasurementaccuracyofdistributedfiberopticsensorsembeddedwithincapillariesofsolidstructures
AT benedictusrinze comprehensivestudyonmeasurementaccuracyofdistributedfiberopticsensorsembeddedwithincapillariesofsolidstructures