Cargando…

Structural Health Monitoring of Chemical Storage Tanks with Application of PZT Sensors

Chemical pressure storage tanks are containers designed to store fluids at high pressures, i.e., their internal pressure is higher than the atmospheric pressure. They can come in various shapes and sizes, and may be fabricated from a variety of materials. As aggressive chemical agents stored under e...

Descripción completa

Detalles Bibliográficos
Autores principales: Dziendzikowski, Michal, Kozera, Paulina, Kowalczyk, Kamil, Dydek, Kamil, Kurkowska, Milena, Krawczyk, Zuzanna D., Gorbacz, Szczepan, Boczkowska, Anna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10574911/
https://www.ncbi.nlm.nih.gov/pubmed/37837082
http://dx.doi.org/10.3390/s23198252
_version_ 1785120799718375424
author Dziendzikowski, Michal
Kozera, Paulina
Kowalczyk, Kamil
Dydek, Kamil
Kurkowska, Milena
Krawczyk, Zuzanna D.
Gorbacz, Szczepan
Boczkowska, Anna
author_facet Dziendzikowski, Michal
Kozera, Paulina
Kowalczyk, Kamil
Dydek, Kamil
Kurkowska, Milena
Krawczyk, Zuzanna D.
Gorbacz, Szczepan
Boczkowska, Anna
author_sort Dziendzikowski, Michal
collection PubMed
description Chemical pressure storage tanks are containers designed to store fluids at high pressures, i.e., their internal pressure is higher than the atmospheric pressure. They can come in various shapes and sizes, and may be fabricated from a variety of materials. As aggressive chemical agents stored under elevated pressures can cause significant damage to both people and the environment, it is essential to develop systems for the early damage detection and the monitoring of structural integrity of such vessels. The development of early damage detection and condition monitoring systems could also help to reduce the maintenance costs associated with periodic inspections of the structure and unforeseen operational breaks due to unmonitored damage development. It could also reduce the related environmental burden. In this paper, we consider a hybrid material composed of glass-fiber-reinforced polymers (GFRPs) and a polyethylene (PE) layer that is suitable for pressurized chemical storage tank manufacturing. GFRPs are used for the outer layer of the tank structure and provides the dominant part of the construction stiffness, while the PE layer is used for protection against the stored chemical medium. The considered damage scenarios include simulated cracks and an erosion of the inner PE layer, as these can be early signs of structural damage leading to the leakage of hazardous liquids, which could compromise safety and, possibly, harm the environment. For damage detection, PZT sensors were selected due to their widely recognized applicability for the purpose of structural health monitoring. For sensor installation, it was assumed that only the outer GFRP layer was available as otherwise sensors could be affected by the stored chemical agent. The main focus of this paper is to verify whether elastic waves excited by PZT sensors, which are installed on the outer GFRP layer, can penetrate the GFRP and PE interface and can be used to detect damage occurring in the inner PE layer. The efficiency of different signal characteristics used for structure evaluation is compared for various frequencies and durations of the excitation signal as well as feasibility of PZT sensor application for passive acquisition of acoustic emission signals is verified.
format Online
Article
Text
id pubmed-10574911
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105749112023-10-14 Structural Health Monitoring of Chemical Storage Tanks with Application of PZT Sensors Dziendzikowski, Michal Kozera, Paulina Kowalczyk, Kamil Dydek, Kamil Kurkowska, Milena Krawczyk, Zuzanna D. Gorbacz, Szczepan Boczkowska, Anna Sensors (Basel) Article Chemical pressure storage tanks are containers designed to store fluids at high pressures, i.e., their internal pressure is higher than the atmospheric pressure. They can come in various shapes and sizes, and may be fabricated from a variety of materials. As aggressive chemical agents stored under elevated pressures can cause significant damage to both people and the environment, it is essential to develop systems for the early damage detection and the monitoring of structural integrity of such vessels. The development of early damage detection and condition monitoring systems could also help to reduce the maintenance costs associated with periodic inspections of the structure and unforeseen operational breaks due to unmonitored damage development. It could also reduce the related environmental burden. In this paper, we consider a hybrid material composed of glass-fiber-reinforced polymers (GFRPs) and a polyethylene (PE) layer that is suitable for pressurized chemical storage tank manufacturing. GFRPs are used for the outer layer of the tank structure and provides the dominant part of the construction stiffness, while the PE layer is used for protection against the stored chemical medium. The considered damage scenarios include simulated cracks and an erosion of the inner PE layer, as these can be early signs of structural damage leading to the leakage of hazardous liquids, which could compromise safety and, possibly, harm the environment. For damage detection, PZT sensors were selected due to their widely recognized applicability for the purpose of structural health monitoring. For sensor installation, it was assumed that only the outer GFRP layer was available as otherwise sensors could be affected by the stored chemical agent. The main focus of this paper is to verify whether elastic waves excited by PZT sensors, which are installed on the outer GFRP layer, can penetrate the GFRP and PE interface and can be used to detect damage occurring in the inner PE layer. The efficiency of different signal characteristics used for structure evaluation is compared for various frequencies and durations of the excitation signal as well as feasibility of PZT sensor application for passive acquisition of acoustic emission signals is verified. MDPI 2023-10-05 /pmc/articles/PMC10574911/ /pubmed/37837082 http://dx.doi.org/10.3390/s23198252 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dziendzikowski, Michal
Kozera, Paulina
Kowalczyk, Kamil
Dydek, Kamil
Kurkowska, Milena
Krawczyk, Zuzanna D.
Gorbacz, Szczepan
Boczkowska, Anna
Structural Health Monitoring of Chemical Storage Tanks with Application of PZT Sensors
title Structural Health Monitoring of Chemical Storage Tanks with Application of PZT Sensors
title_full Structural Health Monitoring of Chemical Storage Tanks with Application of PZT Sensors
title_fullStr Structural Health Monitoring of Chemical Storage Tanks with Application of PZT Sensors
title_full_unstemmed Structural Health Monitoring of Chemical Storage Tanks with Application of PZT Sensors
title_short Structural Health Monitoring of Chemical Storage Tanks with Application of PZT Sensors
title_sort structural health monitoring of chemical storage tanks with application of pzt sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10574911/
https://www.ncbi.nlm.nih.gov/pubmed/37837082
http://dx.doi.org/10.3390/s23198252
work_keys_str_mv AT dziendzikowskimichal structuralhealthmonitoringofchemicalstoragetankswithapplicationofpztsensors
AT kozerapaulina structuralhealthmonitoringofchemicalstoragetankswithapplicationofpztsensors
AT kowalczykkamil structuralhealthmonitoringofchemicalstoragetankswithapplicationofpztsensors
AT dydekkamil structuralhealthmonitoringofchemicalstoragetankswithapplicationofpztsensors
AT kurkowskamilena structuralhealthmonitoringofchemicalstoragetankswithapplicationofpztsensors
AT krawczykzuzannad structuralhealthmonitoringofchemicalstoragetankswithapplicationofpztsensors
AT gorbaczszczepan structuralhealthmonitoringofchemicalstoragetankswithapplicationofpztsensors
AT boczkowskaanna structuralhealthmonitoringofchemicalstoragetankswithapplicationofpztsensors