Cargando…

Structural Design and Verification of an Effective-Area Measurement Device Detection System

The effective-area method is a new way to measure aperture area. It defines aperture area by directly using the beam-limiting effect of the aperture in radiometric measurement. Due to the special structure of the measurement device, it is necessary to find a suitable method to design the detection s...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Xiangzi, Yun, Ziping, You, Ting, Quan, Xiangqian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10575212/
https://www.ncbi.nlm.nih.gov/pubmed/37837045
http://dx.doi.org/10.3390/s23198215
_version_ 1785120872972943360
author Chen, Xiangzi
Yun, Ziping
You, Ting
Quan, Xiangqian
author_facet Chen, Xiangzi
Yun, Ziping
You, Ting
Quan, Xiangqian
author_sort Chen, Xiangzi
collection PubMed
description The effective-area method is a new way to measure aperture area. It defines aperture area by directly using the beam-limiting effect of the aperture in radiometric measurement. Due to the special structure of the measurement device, it is necessary to find a suitable method to design the detection system. In this paper, the measurement system model is constructed in the TracePro program. The real circumstances of light propagation for the measurement beam are simulated, and the responses of the detector are given. It is proved that the relative change in the detector response is the lowest when the detector is at the position of 132°. And this is the best structure design of the detection system. The experimental results are designed to verify the feasibility of the structure design of the detection system.
format Online
Article
Text
id pubmed-10575212
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105752122023-10-14 Structural Design and Verification of an Effective-Area Measurement Device Detection System Chen, Xiangzi Yun, Ziping You, Ting Quan, Xiangqian Sensors (Basel) Communication The effective-area method is a new way to measure aperture area. It defines aperture area by directly using the beam-limiting effect of the aperture in radiometric measurement. Due to the special structure of the measurement device, it is necessary to find a suitable method to design the detection system. In this paper, the measurement system model is constructed in the TracePro program. The real circumstances of light propagation for the measurement beam are simulated, and the responses of the detector are given. It is proved that the relative change in the detector response is the lowest when the detector is at the position of 132°. And this is the best structure design of the detection system. The experimental results are designed to verify the feasibility of the structure design of the detection system. MDPI 2023-10-01 /pmc/articles/PMC10575212/ /pubmed/37837045 http://dx.doi.org/10.3390/s23198215 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Chen, Xiangzi
Yun, Ziping
You, Ting
Quan, Xiangqian
Structural Design and Verification of an Effective-Area Measurement Device Detection System
title Structural Design and Verification of an Effective-Area Measurement Device Detection System
title_full Structural Design and Verification of an Effective-Area Measurement Device Detection System
title_fullStr Structural Design and Verification of an Effective-Area Measurement Device Detection System
title_full_unstemmed Structural Design and Verification of an Effective-Area Measurement Device Detection System
title_short Structural Design and Verification of an Effective-Area Measurement Device Detection System
title_sort structural design and verification of an effective-area measurement device detection system
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10575212/
https://www.ncbi.nlm.nih.gov/pubmed/37837045
http://dx.doi.org/10.3390/s23198215
work_keys_str_mv AT chenxiangzi structuraldesignandverificationofaneffectiveareameasurementdevicedetectionsystem
AT yunziping structuraldesignandverificationofaneffectiveareameasurementdevicedetectionsystem
AT youting structuraldesignandverificationofaneffectiveareameasurementdevicedetectionsystem
AT quanxiangqian structuraldesignandverificationofaneffectiveareameasurementdevicedetectionsystem