Cargando…
A Strain Transfer Model for Detection of Pitting Corrosion and Loading Force of Steel Rebar with Distributed Fiber Optic Sensor
Steel rebar corrosion is one of the predominant factors influencing the durability of marine and offshore reinforced concrete structures, resulting in economic loss and the potential threat to human safety. Distributed fiber optic sensors (DFOSs) have gradually become an effective method for structu...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10575405/ https://www.ncbi.nlm.nih.gov/pubmed/37836971 http://dx.doi.org/10.3390/s23198142 |
Sumario: | Steel rebar corrosion is one of the predominant factors influencing the durability of marine and offshore reinforced concrete structures, resulting in economic loss and the potential threat to human safety. Distributed fiber optic sensors (DFOSs) have gradually become an effective method for structural health monitoring over the past two decades. In this work, a strain transfer model is developed between a steel rebar and a DFOS, considering pitting-corrosion-induced strain variation in the steel rebar. The Gaussian function is first adopted to describe the strain distribution near the corrosion pit of the steel rebar and then is substituted into the governing equation of the strain transfer model, and the strain distribution in the DFOS is analytically obtained. Tensile tests are also conducted on steel rebars with artificially simulated corrosion pits, which are used to validate the developed model. The results show that the Gaussian function can be used to describe the strain variation near a corrosion pit with a depth less than 50% of the steel rebar diameter, and the strain distribution in the DFOS analytically determined based on the developed strain transfer model agrees well with the tensile test results. The corrosion pit depth and loading force in the steel rebars estimated based on the proposed model agree well with the actual values, and therefore, the developed strain transfer model is effective in detecting pitting corrosion and loading force in steel rebars. |
---|