Cargando…

Antimicrobial Efficacy of a Novel Automated Irrigation Device As Compared to Conventional Needle Irrigation Against Enterococcus faecalis: An In Vitro Study

Aim The present study aims to compare the antibacterial efficacy of a novel automated endodontic irrigation device with that of a manual irrigation technique. Materials and methods The present study considered 45 extracted single-rooted teeth. After sectioning the teeth, the specimens were inoculate...

Descripción completa

Detalles Bibliográficos
Autores principales: Choudhari, Sahil, S, Pradeep, Venkata Teja, Kavalipurapu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10576167/
https://www.ncbi.nlm.nih.gov/pubmed/37842411
http://dx.doi.org/10.7759/cureus.45200
_version_ 1785121062912000000
author Choudhari, Sahil
S, Pradeep
Venkata Teja, Kavalipurapu
author_facet Choudhari, Sahil
S, Pradeep
Venkata Teja, Kavalipurapu
author_sort Choudhari, Sahil
collection PubMed
description Aim The present study aims to compare the antibacterial efficacy of a novel automated endodontic irrigation device with that of a manual irrigation technique. Materials and methods The present study considered 45 extracted single-rooted teeth. After sectioning the teeth, the specimens were inoculated with Enterococcus faecalis (E. faecalis) bacteria for three weeks. Instrumentation was done using ProTaper Gold rotary files to size 50 and 5% taper. Based on the irrigation protocol, the experimental samples were divided into Group I: control (normal saline irrigation) (n = 15); Group II: conventional needle irrigation (n = 15); and Group III: automated irrigation (n = 15). The irrigation in Group III was done using the automated irrigation device. After the experimental irrigation, the pre-weighted dentinal shaving was collected in Eppendorf tubes, diluted 10 times, and incubated in the Petri dish with tryptone soy agar (TSA) for 48 hours. Finally, the colony-forming unit (CFU) counts were assessed. IBM SPSS Statistics for Windows version 23.0 (Armonk, NY, USA, IBM Corp.) was used for data analysis. Intergroup comparisons were made using the non-parametric Kruskal-Wallis test. Results The mean CFU count (CFU/ml) for the groups was: Group 1 (normal saline irrigation): 3.67x10(1); Group 2 (manual irrigation): 2.69× 10(1); Group 3 (automated irrigation): 1.57× 10(1). A statistically significant reduction in E. faecalis CFU count was seen among the groups assessed (p<0.01). The automated irrigation group exhibited the most substantial reduction in E. faecalis CFU count. Group 2 showed a significant difference compared to Group 1 (p<0.05). Conclusions The novel automated endodontic irrigation device was superior to manual irrigation in reducing E. faecalis CFU counts. This indicates that the automated irrigation device has the potential to enhance bacterial elimination efficacy during endodontic treatment.
format Online
Article
Text
id pubmed-10576167
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-105761672023-10-15 Antimicrobial Efficacy of a Novel Automated Irrigation Device As Compared to Conventional Needle Irrigation Against Enterococcus faecalis: An In Vitro Study Choudhari, Sahil S, Pradeep Venkata Teja, Kavalipurapu Cureus Pain Management Aim The present study aims to compare the antibacterial efficacy of a novel automated endodontic irrigation device with that of a manual irrigation technique. Materials and methods The present study considered 45 extracted single-rooted teeth. After sectioning the teeth, the specimens were inoculated with Enterococcus faecalis (E. faecalis) bacteria for three weeks. Instrumentation was done using ProTaper Gold rotary files to size 50 and 5% taper. Based on the irrigation protocol, the experimental samples were divided into Group I: control (normal saline irrigation) (n = 15); Group II: conventional needle irrigation (n = 15); and Group III: automated irrigation (n = 15). The irrigation in Group III was done using the automated irrigation device. After the experimental irrigation, the pre-weighted dentinal shaving was collected in Eppendorf tubes, diluted 10 times, and incubated in the Petri dish with tryptone soy agar (TSA) for 48 hours. Finally, the colony-forming unit (CFU) counts were assessed. IBM SPSS Statistics for Windows version 23.0 (Armonk, NY, USA, IBM Corp.) was used for data analysis. Intergroup comparisons were made using the non-parametric Kruskal-Wallis test. Results The mean CFU count (CFU/ml) for the groups was: Group 1 (normal saline irrigation): 3.67x10(1); Group 2 (manual irrigation): 2.69× 10(1); Group 3 (automated irrigation): 1.57× 10(1). A statistically significant reduction in E. faecalis CFU count was seen among the groups assessed (p<0.01). The automated irrigation group exhibited the most substantial reduction in E. faecalis CFU count. Group 2 showed a significant difference compared to Group 1 (p<0.05). Conclusions The novel automated endodontic irrigation device was superior to manual irrigation in reducing E. faecalis CFU counts. This indicates that the automated irrigation device has the potential to enhance bacterial elimination efficacy during endodontic treatment. Cureus 2023-09-14 /pmc/articles/PMC10576167/ /pubmed/37842411 http://dx.doi.org/10.7759/cureus.45200 Text en Copyright © 2023, Choudhari et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Pain Management
Choudhari, Sahil
S, Pradeep
Venkata Teja, Kavalipurapu
Antimicrobial Efficacy of a Novel Automated Irrigation Device As Compared to Conventional Needle Irrigation Against Enterococcus faecalis: An In Vitro Study
title Antimicrobial Efficacy of a Novel Automated Irrigation Device As Compared to Conventional Needle Irrigation Against Enterococcus faecalis: An In Vitro Study
title_full Antimicrobial Efficacy of a Novel Automated Irrigation Device As Compared to Conventional Needle Irrigation Against Enterococcus faecalis: An In Vitro Study
title_fullStr Antimicrobial Efficacy of a Novel Automated Irrigation Device As Compared to Conventional Needle Irrigation Against Enterococcus faecalis: An In Vitro Study
title_full_unstemmed Antimicrobial Efficacy of a Novel Automated Irrigation Device As Compared to Conventional Needle Irrigation Against Enterococcus faecalis: An In Vitro Study
title_short Antimicrobial Efficacy of a Novel Automated Irrigation Device As Compared to Conventional Needle Irrigation Against Enterococcus faecalis: An In Vitro Study
title_sort antimicrobial efficacy of a novel automated irrigation device as compared to conventional needle irrigation against enterococcus faecalis: an in vitro study
topic Pain Management
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10576167/
https://www.ncbi.nlm.nih.gov/pubmed/37842411
http://dx.doi.org/10.7759/cureus.45200
work_keys_str_mv AT choudharisahil antimicrobialefficacyofanovelautomatedirrigationdeviceascomparedtoconventionalneedleirrigationagainstenterococcusfaecalisaninvitrostudy
AT spradeep antimicrobialefficacyofanovelautomatedirrigationdeviceascomparedtoconventionalneedleirrigationagainstenterococcusfaecalisaninvitrostudy
AT venkatatejakavalipurapu antimicrobialefficacyofanovelautomatedirrigationdeviceascomparedtoconventionalneedleirrigationagainstenterococcusfaecalisaninvitrostudy