A retrospective study of dynamic navigation system-assisted implant placement
BACKGROUND: To evaluate the accuracy of implant placement assisted by a dynamic navigation system, as well as its influencing factors and learning curve. METHODS: At Macao We Care Dental Center, 55 cases of implant placement using dynamic navigation were retrospectively evaluated. To evaluate their...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10576318/ https://www.ncbi.nlm.nih.gov/pubmed/37838655 http://dx.doi.org/10.1186/s12903-023-03481-2 |
_version_ | 1785121095424147456 |
---|---|
author | Ma, Lijuan Ye, Mingjun Wu, Mingle Chen, Xiaolei Shen, Shan |
author_facet | Ma, Lijuan Ye, Mingjun Wu, Mingle Chen, Xiaolei Shen, Shan |
author_sort | Ma, Lijuan |
collection | PubMed |
description | BACKGROUND: To evaluate the accuracy of implant placement assisted by a dynamic navigation system, as well as its influencing factors and learning curve. METHODS: At Macao We Care Dental Center, 55 cases of implant placement using dynamic navigation were retrospectively evaluated. To evaluate their accuracy, the apex, tip, and angle deviations of preoperatively planned and postoperatively placed implants were measured. The effects of the upper and lower jaws, different sites or lateral locations of dental implants, and the length and diameter of the implants on accuracy were analyzed, as well as the variation in accuracy with the increase in the number of surgical procedures performed by dentists. RESULTS: The implant had an apex deviation of 1.60 ± 0.94 mm, a tip deviation of 1.83 ± 1.03 mm, and an angle deviation of 3.80 ± 2.09 mm. Statistical differences were observed in the tip deviation of implants at different positions based on three factors: jaw position, lateral location, and tooth position (P < 0.05). The tip deviation of the anterior teeth area was significantly greater than those of the premolar and molar areas. There were no statistically significant differences in apex deviation, tip deviation, or angle deviation between the implants of different diameters and lengths (P > 0.05). There were significant differences in the angle deviation between the final 27 implants and the first 28 implants. Learning curve analysis revealed that angle deviation was negatively correlated with the number of surgical procedures, whereas the regression of apex deviation and tip deviation did not differ statistically. CONCLUSIONS: The accuracy of dynamic navigation-assisted dental implants meets the clinical needs and is higher than that of traditional implants. Different jaw positions, lateral locations, and implant diameters and lengths had no effect on the accuracy of the dental implants guided by the dynamic navigation system. The anterior teeth area had a larger tip deviation than the posterior teeth area did. As the number of dynamic implantation procedures performed by the same implant doctor increased, the angle deviation gradually decreased. |
format | Online Article Text |
id | pubmed-10576318 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-105763182023-10-15 A retrospective study of dynamic navigation system-assisted implant placement Ma, Lijuan Ye, Mingjun Wu, Mingle Chen, Xiaolei Shen, Shan BMC Oral Health Research BACKGROUND: To evaluate the accuracy of implant placement assisted by a dynamic navigation system, as well as its influencing factors and learning curve. METHODS: At Macao We Care Dental Center, 55 cases of implant placement using dynamic navigation were retrospectively evaluated. To evaluate their accuracy, the apex, tip, and angle deviations of preoperatively planned and postoperatively placed implants were measured. The effects of the upper and lower jaws, different sites or lateral locations of dental implants, and the length and diameter of the implants on accuracy were analyzed, as well as the variation in accuracy with the increase in the number of surgical procedures performed by dentists. RESULTS: The implant had an apex deviation of 1.60 ± 0.94 mm, a tip deviation of 1.83 ± 1.03 mm, and an angle deviation of 3.80 ± 2.09 mm. Statistical differences were observed in the tip deviation of implants at different positions based on three factors: jaw position, lateral location, and tooth position (P < 0.05). The tip deviation of the anterior teeth area was significantly greater than those of the premolar and molar areas. There were no statistically significant differences in apex deviation, tip deviation, or angle deviation between the implants of different diameters and lengths (P > 0.05). There were significant differences in the angle deviation between the final 27 implants and the first 28 implants. Learning curve analysis revealed that angle deviation was negatively correlated with the number of surgical procedures, whereas the regression of apex deviation and tip deviation did not differ statistically. CONCLUSIONS: The accuracy of dynamic navigation-assisted dental implants meets the clinical needs and is higher than that of traditional implants. Different jaw positions, lateral locations, and implant diameters and lengths had no effect on the accuracy of the dental implants guided by the dynamic navigation system. The anterior teeth area had a larger tip deviation than the posterior teeth area did. As the number of dynamic implantation procedures performed by the same implant doctor increased, the angle deviation gradually decreased. BioMed Central 2023-10-14 /pmc/articles/PMC10576318/ /pubmed/37838655 http://dx.doi.org/10.1186/s12903-023-03481-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Ma, Lijuan Ye, Mingjun Wu, Mingle Chen, Xiaolei Shen, Shan A retrospective study of dynamic navigation system-assisted implant placement |
title | A retrospective study of dynamic navigation system-assisted implant placement |
title_full | A retrospective study of dynamic navigation system-assisted implant placement |
title_fullStr | A retrospective study of dynamic navigation system-assisted implant placement |
title_full_unstemmed | A retrospective study of dynamic navigation system-assisted implant placement |
title_short | A retrospective study of dynamic navigation system-assisted implant placement |
title_sort | retrospective study of dynamic navigation system-assisted implant placement |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10576318/ https://www.ncbi.nlm.nih.gov/pubmed/37838655 http://dx.doi.org/10.1186/s12903-023-03481-2 |
work_keys_str_mv | AT malijuan aretrospectivestudyofdynamicnavigationsystemassistedimplantplacement AT yemingjun aretrospectivestudyofdynamicnavigationsystemassistedimplantplacement AT wumingle aretrospectivestudyofdynamicnavigationsystemassistedimplantplacement AT chenxiaolei aretrospectivestudyofdynamicnavigationsystemassistedimplantplacement AT shenshan aretrospectivestudyofdynamicnavigationsystemassistedimplantplacement AT malijuan retrospectivestudyofdynamicnavigationsystemassistedimplantplacement AT yemingjun retrospectivestudyofdynamicnavigationsystemassistedimplantplacement AT wumingle retrospectivestudyofdynamicnavigationsystemassistedimplantplacement AT chenxiaolei retrospectivestudyofdynamicnavigationsystemassistedimplantplacement AT shenshan retrospectivestudyofdynamicnavigationsystemassistedimplantplacement |