Cargando…

Test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels

Single-pulse Transcranial Magnetic Stimulation (TMS) and, very recently, lumbar stimulation (LS) have been used to measure cortico-spinal excitability from various interventions using maximal or submaximal contractions in the lower limbs. However, reliability studies have overlooked a wide range of...

Descripción completa

Detalles Bibliográficos
Autores principales: Gomez-Guerrero, Gonzalo, Avela, Janne, Enroth, Miro, Häkkinen, Ella, Ansdell, Paul, Howatson, Glyn, Walker, Simon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10577233/
https://www.ncbi.nlm.nih.gov/pubmed/37849888
http://dx.doi.org/10.3389/fnins.2023.1239982
_version_ 1785121281629224960
author Gomez-Guerrero, Gonzalo
Avela, Janne
Enroth, Miro
Häkkinen, Ella
Ansdell, Paul
Howatson, Glyn
Walker, Simon
author_facet Gomez-Guerrero, Gonzalo
Avela, Janne
Enroth, Miro
Häkkinen, Ella
Ansdell, Paul
Howatson, Glyn
Walker, Simon
author_sort Gomez-Guerrero, Gonzalo
collection PubMed
description Single-pulse Transcranial Magnetic Stimulation (TMS) and, very recently, lumbar stimulation (LS) have been used to measure cortico-spinal excitability from various interventions using maximal or submaximal contractions in the lower limbs. However, reliability studies have overlooked a wide range of contraction intensities for MEPs, and no reliability data is available for LEPs. This study investigated the reliability of motor evoked potentials and lumbar evoked potentials at different stimulation intensities and contraction levels in m.rectus femoris. Twenty-two participants performed non-fatiguing isometric knee extensions at 20 and 60% of maximum voluntary contraction (MVC). LS induced a lumbar-evoked potential (LEP) of 25 and 50% resting maximal compound action potential (M-max). TMS stimulator output was adjusted to 120, 140, and 160% of active motor threshold (aMT). In each contraction, a single MEP or LEP was delivered. Ten contractions were performed at each stimulator intensity and contraction level in random order. Moderate-to-good reliability was found when LEP was normalized to M-max/Root Mean Square in all conditions (ICC:0.74–0.85). Excellent reliability was found when MEP was normalized to Mmax for all conditions (ICC > 0.90) at 60% of MVC. Good reliability was found for the rest of the TMS conditions. Moderate-to-good reliability was found for silent period (SP) elicited by LS (ICC: 0.71–0.83). Good-to-excellent reliability was found for SP elicited by TMS (ICC > 0.82). MEPs and LEPs elicited in m.rectus femoris appear to be reliable to assess changes at different segments of the cortico-spinal tract during different contraction levels and stimulator output intensities. Furthermore, the TMS- and LS- elicited SP was a reliable tool considered to reflect inhibitory processes at spinal and cortical levels.
format Online
Article
Text
id pubmed-10577233
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-105772332023-10-17 Test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels Gomez-Guerrero, Gonzalo Avela, Janne Enroth, Miro Häkkinen, Ella Ansdell, Paul Howatson, Glyn Walker, Simon Front Neurosci Neuroscience Single-pulse Transcranial Magnetic Stimulation (TMS) and, very recently, lumbar stimulation (LS) have been used to measure cortico-spinal excitability from various interventions using maximal or submaximal contractions in the lower limbs. However, reliability studies have overlooked a wide range of contraction intensities for MEPs, and no reliability data is available for LEPs. This study investigated the reliability of motor evoked potentials and lumbar evoked potentials at different stimulation intensities and contraction levels in m.rectus femoris. Twenty-two participants performed non-fatiguing isometric knee extensions at 20 and 60% of maximum voluntary contraction (MVC). LS induced a lumbar-evoked potential (LEP) of 25 and 50% resting maximal compound action potential (M-max). TMS stimulator output was adjusted to 120, 140, and 160% of active motor threshold (aMT). In each contraction, a single MEP or LEP was delivered. Ten contractions were performed at each stimulator intensity and contraction level in random order. Moderate-to-good reliability was found when LEP was normalized to M-max/Root Mean Square in all conditions (ICC:0.74–0.85). Excellent reliability was found when MEP was normalized to Mmax for all conditions (ICC > 0.90) at 60% of MVC. Good reliability was found for the rest of the TMS conditions. Moderate-to-good reliability was found for silent period (SP) elicited by LS (ICC: 0.71–0.83). Good-to-excellent reliability was found for SP elicited by TMS (ICC > 0.82). MEPs and LEPs elicited in m.rectus femoris appear to be reliable to assess changes at different segments of the cortico-spinal tract during different contraction levels and stimulator output intensities. Furthermore, the TMS- and LS- elicited SP was a reliable tool considered to reflect inhibitory processes at spinal and cortical levels. Frontiers Media S.A. 2023-10-02 /pmc/articles/PMC10577233/ /pubmed/37849888 http://dx.doi.org/10.3389/fnins.2023.1239982 Text en Copyright © 2023 Gomez-Guerrero, Avela, Enroth, Häkkinen, Ansdell, Howatson and Walker. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Gomez-Guerrero, Gonzalo
Avela, Janne
Enroth, Miro
Häkkinen, Ella
Ansdell, Paul
Howatson, Glyn
Walker, Simon
Test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels
title Test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels
title_full Test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels
title_fullStr Test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels
title_full_unstemmed Test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels
title_short Test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels
title_sort test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10577233/
https://www.ncbi.nlm.nih.gov/pubmed/37849888
http://dx.doi.org/10.3389/fnins.2023.1239982
work_keys_str_mv AT gomezguerrerogonzalo testretestreliabilityofcorticospinalmeasurementsintherectusfemorisatdifferentcontractionlevels
AT avelajanne testretestreliabilityofcorticospinalmeasurementsintherectusfemorisatdifferentcontractionlevels
AT enrothmiro testretestreliabilityofcorticospinalmeasurementsintherectusfemorisatdifferentcontractionlevels
AT hakkinenella testretestreliabilityofcorticospinalmeasurementsintherectusfemorisatdifferentcontractionlevels
AT ansdellpaul testretestreliabilityofcorticospinalmeasurementsintherectusfemorisatdifferentcontractionlevels
AT howatsonglyn testretestreliabilityofcorticospinalmeasurementsintherectusfemorisatdifferentcontractionlevels
AT walkersimon testretestreliabilityofcorticospinalmeasurementsintherectusfemorisatdifferentcontractionlevels