Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies
BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment option for heart failure patients. However, the implementation of triple‐chamber pacemakers can be cost‐prohibitive. His‐Purkinje system pacing (HPSP) can also enable cardiac resynchronization, and it can be achieved wit...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10577564/ https://www.ncbi.nlm.nih.gov/pubmed/37537947 http://dx.doi.org/10.1002/clc.24107 |
_version_ | 1785121352812855296 |
---|---|
author | Chen, Mengna Shi, Jing Zhang, Yimin Ge, Xiaozhen Zhang, Xu Fan, Wenbin Wang, Shuo Guo, Zhiqin Guan, Jian Wu, Yongquan Zhang, Junmeng |
author_facet | Chen, Mengna Shi, Jing Zhang, Yimin Ge, Xiaozhen Zhang, Xu Fan, Wenbin Wang, Shuo Guo, Zhiqin Guan, Jian Wu, Yongquan Zhang, Junmeng |
author_sort | Chen, Mengna |
collection | PubMed |
description | BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment option for heart failure patients. However, the implementation of triple‐chamber pacemakers can be cost‐prohibitive. His‐Purkinje system pacing (HPSP) can also enable cardiac resynchronization, and it can be achieved with relatively inexpensive conventional pacemakers. HYPOTHESIS: This article aims to comparatively evaluate the cost of implanting devices in different CRT strategies to provide meaningful guidance for clinical decision‐making by electrophysiologists. METHODS: Data was collected on the prices, designed life, and price/designed life of multiple mainstream models of CRT‐P, CRT‐D, dual‐chamber pacemakers, and single‐chamber pacemakers that were sold in the Chinese market in 2022. The prices, designed lives, and price/designed life of different pacemaker models were then compared. RESULTS: The costs of CRT‐P and CRT‐D (13008.44 ± 2752.30 USD and 22043.36 ± 3676.25 USD) were significantly higher than those of conventional pacemakers (dual‐chamber: 11142.39 ± 4273.85 USD and single‐chamber: 5634.28 ± 2032.80 USD) (p < .05). Additionally, the price/designed life of conventional pacemakers (dual‐chamber: 839.63 ± 258.62 US dollar/year and single‐chamber: 435.86 ± 125.44 US dollar/year) was significantly better than that of CRT‐P and CRT‐D (1386.91 ± 266.73 and 2585.53 ± 520.27 US dollar/year, respectively) (p < .05). CONCLUSION: Conduction system pacing (CSP)‐based CRT is more cost‐effective than BVP‐based CRT. Furthermore, CSP‐based CRT can achieve cardiac resynchronization with conventional pacemakers and may be a good option for HF patients who do not need defibrillation. |
format | Online Article Text |
id | pubmed-10577564 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-105775642023-10-17 Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies Chen, Mengna Shi, Jing Zhang, Yimin Ge, Xiaozhen Zhang, Xu Fan, Wenbin Wang, Shuo Guo, Zhiqin Guan, Jian Wu, Yongquan Zhang, Junmeng Clin Cardiol Clinical Investigations BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment option for heart failure patients. However, the implementation of triple‐chamber pacemakers can be cost‐prohibitive. His‐Purkinje system pacing (HPSP) can also enable cardiac resynchronization, and it can be achieved with relatively inexpensive conventional pacemakers. HYPOTHESIS: This article aims to comparatively evaluate the cost of implanting devices in different CRT strategies to provide meaningful guidance for clinical decision‐making by electrophysiologists. METHODS: Data was collected on the prices, designed life, and price/designed life of multiple mainstream models of CRT‐P, CRT‐D, dual‐chamber pacemakers, and single‐chamber pacemakers that were sold in the Chinese market in 2022. The prices, designed lives, and price/designed life of different pacemaker models were then compared. RESULTS: The costs of CRT‐P and CRT‐D (13008.44 ± 2752.30 USD and 22043.36 ± 3676.25 USD) were significantly higher than those of conventional pacemakers (dual‐chamber: 11142.39 ± 4273.85 USD and single‐chamber: 5634.28 ± 2032.80 USD) (p < .05). Additionally, the price/designed life of conventional pacemakers (dual‐chamber: 839.63 ± 258.62 US dollar/year and single‐chamber: 435.86 ± 125.44 US dollar/year) was significantly better than that of CRT‐P and CRT‐D (1386.91 ± 266.73 and 2585.53 ± 520.27 US dollar/year, respectively) (p < .05). CONCLUSION: Conduction system pacing (CSP)‐based CRT is more cost‐effective than BVP‐based CRT. Furthermore, CSP‐based CRT can achieve cardiac resynchronization with conventional pacemakers and may be a good option for HF patients who do not need defibrillation. John Wiley and Sons Inc. 2023-08-03 /pmc/articles/PMC10577564/ /pubmed/37537947 http://dx.doi.org/10.1002/clc.24107 Text en © 2023 The Authors. Clinical Cardiology published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Investigations Chen, Mengna Shi, Jing Zhang, Yimin Ge, Xiaozhen Zhang, Xu Fan, Wenbin Wang, Shuo Guo, Zhiqin Guan, Jian Wu, Yongquan Zhang, Junmeng Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies |
title | Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies |
title_full | Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies |
title_fullStr | Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies |
title_full_unstemmed | Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies |
title_short | Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies |
title_sort | comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies |
topic | Clinical Investigations |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10577564/ https://www.ncbi.nlm.nih.gov/pubmed/37537947 http://dx.doi.org/10.1002/clc.24107 |
work_keys_str_mv | AT chenmengna comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies AT shijing comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies AT zhangyimin comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies AT gexiaozhen comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies AT zhangxu comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies AT fanwenbin comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies AT wangshuo comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies AT guozhiqin comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies AT guanjian comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies AT wuyongquan comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies AT zhangjunmeng comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies |