Cargando…

Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies

BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment option for heart failure patients. However, the implementation of triple‐chamber pacemakers can be cost‐prohibitive. His‐Purkinje system pacing (HPSP) can also enable cardiac resynchronization, and it can be achieved wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Mengna, Shi, Jing, Zhang, Yimin, Ge, Xiaozhen, Zhang, Xu, Fan, Wenbin, Wang, Shuo, Guo, Zhiqin, Guan, Jian, Wu, Yongquan, Zhang, Junmeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10577564/
https://www.ncbi.nlm.nih.gov/pubmed/37537947
http://dx.doi.org/10.1002/clc.24107
_version_ 1785121352812855296
author Chen, Mengna
Shi, Jing
Zhang, Yimin
Ge, Xiaozhen
Zhang, Xu
Fan, Wenbin
Wang, Shuo
Guo, Zhiqin
Guan, Jian
Wu, Yongquan
Zhang, Junmeng
author_facet Chen, Mengna
Shi, Jing
Zhang, Yimin
Ge, Xiaozhen
Zhang, Xu
Fan, Wenbin
Wang, Shuo
Guo, Zhiqin
Guan, Jian
Wu, Yongquan
Zhang, Junmeng
author_sort Chen, Mengna
collection PubMed
description BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment option for heart failure patients. However, the implementation of triple‐chamber pacemakers can be cost‐prohibitive. His‐Purkinje system pacing (HPSP) can also enable cardiac resynchronization, and it can be achieved with relatively inexpensive conventional pacemakers. HYPOTHESIS: This article aims to comparatively evaluate the cost of implanting devices in different CRT strategies to provide meaningful guidance for clinical decision‐making by electrophysiologists. METHODS: Data was collected on the prices, designed life, and price/designed life of multiple mainstream models of CRT‐P, CRT‐D, dual‐chamber pacemakers, and single‐chamber pacemakers that were sold in the Chinese market in 2022. The prices, designed lives, and price/designed life of different pacemaker models were then compared. RESULTS: The costs of CRT‐P and CRT‐D (13008.44 ± 2752.30 USD and 22043.36 ± 3676.25 USD) were significantly higher than those of conventional pacemakers (dual‐chamber: 11142.39 ± 4273.85 USD and single‐chamber: 5634.28 ± 2032.80 USD) (p < .05). Additionally, the price/designed life of conventional pacemakers (dual‐chamber: 839.63 ± 258.62 US dollar/year and single‐chamber: 435.86 ± 125.44 US dollar/year) was significantly better than that of CRT‐P and CRT‐D (1386.91 ± 266.73 and 2585.53 ± 520.27 US dollar/year, respectively) (p < .05). CONCLUSION: Conduction system pacing (CSP)‐based CRT is more cost‐effective than BVP‐based CRT. Furthermore, CSP‐based CRT can achieve cardiac resynchronization with conventional pacemakers and may be a good option for HF patients who do not need defibrillation.
format Online
Article
Text
id pubmed-10577564
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-105775642023-10-17 Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies Chen, Mengna Shi, Jing Zhang, Yimin Ge, Xiaozhen Zhang, Xu Fan, Wenbin Wang, Shuo Guo, Zhiqin Guan, Jian Wu, Yongquan Zhang, Junmeng Clin Cardiol Clinical Investigations BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment option for heart failure patients. However, the implementation of triple‐chamber pacemakers can be cost‐prohibitive. His‐Purkinje system pacing (HPSP) can also enable cardiac resynchronization, and it can be achieved with relatively inexpensive conventional pacemakers. HYPOTHESIS: This article aims to comparatively evaluate the cost of implanting devices in different CRT strategies to provide meaningful guidance for clinical decision‐making by electrophysiologists. METHODS: Data was collected on the prices, designed life, and price/designed life of multiple mainstream models of CRT‐P, CRT‐D, dual‐chamber pacemakers, and single‐chamber pacemakers that were sold in the Chinese market in 2022. The prices, designed lives, and price/designed life of different pacemaker models were then compared. RESULTS: The costs of CRT‐P and CRT‐D (13008.44 ± 2752.30 USD and 22043.36 ± 3676.25 USD) were significantly higher than those of conventional pacemakers (dual‐chamber: 11142.39 ± 4273.85 USD and single‐chamber: 5634.28 ± 2032.80 USD) (p < .05). Additionally, the price/designed life of conventional pacemakers (dual‐chamber: 839.63 ± 258.62 US dollar/year and single‐chamber: 435.86 ± 125.44 US dollar/year) was significantly better than that of CRT‐P and CRT‐D (1386.91 ± 266.73 and 2585.53 ± 520.27 US dollar/year, respectively) (p < .05). CONCLUSION: Conduction system pacing (CSP)‐based CRT is more cost‐effective than BVP‐based CRT. Furthermore, CSP‐based CRT can achieve cardiac resynchronization with conventional pacemakers and may be a good option for HF patients who do not need defibrillation. John Wiley and Sons Inc. 2023-08-03 /pmc/articles/PMC10577564/ /pubmed/37537947 http://dx.doi.org/10.1002/clc.24107 Text en © 2023 The Authors. Clinical Cardiology published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Investigations
Chen, Mengna
Shi, Jing
Zhang, Yimin
Ge, Xiaozhen
Zhang, Xu
Fan, Wenbin
Wang, Shuo
Guo, Zhiqin
Guan, Jian
Wu, Yongquan
Zhang, Junmeng
Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies
title Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies
title_full Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies
title_fullStr Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies
title_full_unstemmed Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies
title_short Comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies
title_sort comparative cost analysis of implanting devices in different cardiac resynchronization therapeutic strategies
topic Clinical Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10577564/
https://www.ncbi.nlm.nih.gov/pubmed/37537947
http://dx.doi.org/10.1002/clc.24107
work_keys_str_mv AT chenmengna comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies
AT shijing comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies
AT zhangyimin comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies
AT gexiaozhen comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies
AT zhangxu comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies
AT fanwenbin comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies
AT wangshuo comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies
AT guozhiqin comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies
AT guanjian comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies
AT wuyongquan comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies
AT zhangjunmeng comparativecostanalysisofimplantingdevicesindifferentcardiacresynchronizationtherapeuticstrategies