Cargando…

A Comparative Analysis of Liquid-Based Cytology and Conventional Smears in Fine-Needle Aspirates of Thyroid Lesions

Background Palpable nodules in the thyroid are present in 4-7% of the general population. Fine-needle aspiration cytology is a safe and cost-effective method of choice for evaluating thyroid nodules. Aspirated samples can be manually spread directly onto the slide and stained in the conventional sme...

Descripción completa

Detalles Bibliográficos
Autores principales: Maurya, Malti K, Yadav, Rita, Kumar, Madhu, Singh, Hitendra P, Mishra, Anand, Goel, Madhu Mati
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10578099/
https://www.ncbi.nlm.nih.gov/pubmed/37849573
http://dx.doi.org/10.7759/cureus.45353
_version_ 1785121447883046912
author Maurya, Malti K
Yadav, Rita
Kumar, Madhu
Singh, Hitendra P
Mishra, Anand
Goel, Madhu Mati
author_facet Maurya, Malti K
Yadav, Rita
Kumar, Madhu
Singh, Hitendra P
Mishra, Anand
Goel, Madhu Mati
author_sort Maurya, Malti K
collection PubMed
description Background Palpable nodules in the thyroid are present in 4-7% of the general population. Fine-needle aspiration cytology is a safe and cost-effective method of choice for evaluating thyroid nodules. Aspirated samples can be manually spread directly onto the slide and stained in the conventional smear method. The liquid-cased cytology method has been recently introduced, which is an automated machine-based method, yielding a single slide with a clean background and greater preservation of cells and consuming less time for screening. This study aimed to compare the cytomorphological features and diagnostic accuracy of conventional smears and liquid-based cytology smears. Methodology This prospective study comprised 250 cases of thyroid lesions. Fine-needle aspiration cytology using conventional smears and liquid-based cytology smears was reported per the Bethesda system of reporting thyroid cytopathology. Detailed cytomorphological features were evaluated and compared in both techniques. Results The cellularity of conventional smears was significantly higher for scores 2+ and 3+ than paired liquid-based cytology smears (paired t-test, p < 0.001). The overall diagnostic efficacy of conventional smears and liquid-based cytology smears was equivalent in the majority of cases (n = 171, 68.4%). Conventional smears were better than liquid-cased cytology smears in 34 (13.6%) cases, and liquid-based cytology smears were better than conventional smears in eight (3.2%) cases. Liquid-based cytology smears showed a higher unsatisfactory rate compared to conventional Smears (15.6% vs. 5.2%). The sensitivity and specificity of conventional smears were 84.6% and 94.4%, respectively, compared to 68.7% and 92.4%, respectively, of liquid-based cytology smears. Conclusions Conventional smears are a cost-effective and easy method for diagnosing thyroid nodules. Liquid-based cytology smears can be used in association with conventional smears to enhance the accuracy of the evaluation of malignant thyroid nodules.
format Online
Article
Text
id pubmed-10578099
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-105780992023-10-17 A Comparative Analysis of Liquid-Based Cytology and Conventional Smears in Fine-Needle Aspirates of Thyroid Lesions Maurya, Malti K Yadav, Rita Kumar, Madhu Singh, Hitendra P Mishra, Anand Goel, Madhu Mati Cureus Otolaryngology Background Palpable nodules in the thyroid are present in 4-7% of the general population. Fine-needle aspiration cytology is a safe and cost-effective method of choice for evaluating thyroid nodules. Aspirated samples can be manually spread directly onto the slide and stained in the conventional smear method. The liquid-cased cytology method has been recently introduced, which is an automated machine-based method, yielding a single slide with a clean background and greater preservation of cells and consuming less time for screening. This study aimed to compare the cytomorphological features and diagnostic accuracy of conventional smears and liquid-based cytology smears. Methodology This prospective study comprised 250 cases of thyroid lesions. Fine-needle aspiration cytology using conventional smears and liquid-based cytology smears was reported per the Bethesda system of reporting thyroid cytopathology. Detailed cytomorphological features were evaluated and compared in both techniques. Results The cellularity of conventional smears was significantly higher for scores 2+ and 3+ than paired liquid-based cytology smears (paired t-test, p < 0.001). The overall diagnostic efficacy of conventional smears and liquid-based cytology smears was equivalent in the majority of cases (n = 171, 68.4%). Conventional smears were better than liquid-cased cytology smears in 34 (13.6%) cases, and liquid-based cytology smears were better than conventional smears in eight (3.2%) cases. Liquid-based cytology smears showed a higher unsatisfactory rate compared to conventional Smears (15.6% vs. 5.2%). The sensitivity and specificity of conventional smears were 84.6% and 94.4%, respectively, compared to 68.7% and 92.4%, respectively, of liquid-based cytology smears. Conclusions Conventional smears are a cost-effective and easy method for diagnosing thyroid nodules. Liquid-based cytology smears can be used in association with conventional smears to enhance the accuracy of the evaluation of malignant thyroid nodules. Cureus 2023-09-16 /pmc/articles/PMC10578099/ /pubmed/37849573 http://dx.doi.org/10.7759/cureus.45353 Text en Copyright © 2023, Maurya et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Otolaryngology
Maurya, Malti K
Yadav, Rita
Kumar, Madhu
Singh, Hitendra P
Mishra, Anand
Goel, Madhu Mati
A Comparative Analysis of Liquid-Based Cytology and Conventional Smears in Fine-Needle Aspirates of Thyroid Lesions
title A Comparative Analysis of Liquid-Based Cytology and Conventional Smears in Fine-Needle Aspirates of Thyroid Lesions
title_full A Comparative Analysis of Liquid-Based Cytology and Conventional Smears in Fine-Needle Aspirates of Thyroid Lesions
title_fullStr A Comparative Analysis of Liquid-Based Cytology and Conventional Smears in Fine-Needle Aspirates of Thyroid Lesions
title_full_unstemmed A Comparative Analysis of Liquid-Based Cytology and Conventional Smears in Fine-Needle Aspirates of Thyroid Lesions
title_short A Comparative Analysis of Liquid-Based Cytology and Conventional Smears in Fine-Needle Aspirates of Thyroid Lesions
title_sort comparative analysis of liquid-based cytology and conventional smears in fine-needle aspirates of thyroid lesions
topic Otolaryngology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10578099/
https://www.ncbi.nlm.nih.gov/pubmed/37849573
http://dx.doi.org/10.7759/cureus.45353
work_keys_str_mv AT mauryamaltik acomparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT yadavrita acomparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT kumarmadhu acomparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT singhhitendrap acomparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT mishraanand acomparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT goelmadhumati acomparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT mauryamaltik comparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT yadavrita comparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT kumarmadhu comparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT singhhitendrap comparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT mishraanand comparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions
AT goelmadhumati comparativeanalysisofliquidbasedcytologyandconventionalsmearsinfineneedleaspiratesofthyroidlesions