Cargando…
The Impact of Deep Inspiration Breath Hold (DIBH) Implementation on the Hybrid Technique in Left-Sided Whole Breast Irradiation: A Dosimetric Characteristic Study of 3D-CRT Hybrid VMAT in DIBH and Free Breathing Conditions, and VMAT in Free Breathing Conditions
AIM: To investigate the impact of DIBH for heart sparing effect on left sided breast postoperative whole breast irradiation by comparing the dosimetric characteristics of 3D-CRT hybrid VMAT and pure VMAT treatment planning under DIBH condition. MATERIALS AND METHODS: The primary CT data sets from pr...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10578161/ https://www.ncbi.nlm.nih.gov/pubmed/37850030 http://dx.doi.org/10.2147/BCTT.S426903 |
_version_ | 1785121459241222144 |
---|---|
author | Yeh, Hui-Ling Lin, Jia-Fu |
author_facet | Yeh, Hui-Ling Lin, Jia-Fu |
author_sort | Yeh, Hui-Ling |
collection | PubMed |
description | AIM: To investigate the impact of DIBH for heart sparing effect on left sided breast postoperative whole breast irradiation by comparing the dosimetric characteristics of 3D-CRT hybrid VMAT and pure VMAT treatment planning under DIBH condition. MATERIALS AND METHODS: The primary CT data sets from previously treated left sided early breast cancer were used for pure volumetric arc therapy (VMAT) technique re-planning for the dosimetric characteristics comparison. A treatment plan of 3D-CRT hybrid VMAT technique was re-planned on the free breath (FB) condition for the investigation of the dosimetric characteristics comparison on DIBH condition. The prescribed dose for all the treatment plans was 42.5Gy in 16 fractions. All plans were optimized to cover 100% of the PTV by 95% of prescribed dose. The dosimetric differences among the 3 treatment plans for the 20 patients were analyzed using Wilcoxon signed-rank test, with p value<0.05 considered statistically significant. RESULTS: 3D-CRT hybrid VMAT using DIBH technique yielded the best results on the conformity index (CI) and homogeneity index (HI). By comparing this 3D-CRT hybrid VMAT technique using FB and DIBH technique, the mean heart dose (MHD) was reduced from 5.38Gy to 1.65Gy, respectively (p =0.001) and the left anterior descending coronary artery (LAD)0.03cc dose was reduced from 27.87Gy to 9.41Gy, respectively (p =0.001). 3D-CRT hybrid VMAT using DIBH technique significantly reduced the V5, V20 and D mean of the ipsilateral lung and D mean of the contralateral lung. The D5 of right breast was significantly reduced by 3D-CRT hybrid VMAT compared with VMAT using DIBH technique. CONCLUSION: The incorporation of DIBH into 3D-CRT hybrid VMAT technique provides the best benefits for the heart and the OAR with respect to the radiation dose-sparing effect without compromising the target conformity and homogeneity in the treatment planning. |
format | Online Article Text |
id | pubmed-10578161 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-105781612023-10-17 The Impact of Deep Inspiration Breath Hold (DIBH) Implementation on the Hybrid Technique in Left-Sided Whole Breast Irradiation: A Dosimetric Characteristic Study of 3D-CRT Hybrid VMAT in DIBH and Free Breathing Conditions, and VMAT in Free Breathing Conditions Yeh, Hui-Ling Lin, Jia-Fu Breast Cancer (Dove Med Press) Original Research AIM: To investigate the impact of DIBH for heart sparing effect on left sided breast postoperative whole breast irradiation by comparing the dosimetric characteristics of 3D-CRT hybrid VMAT and pure VMAT treatment planning under DIBH condition. MATERIALS AND METHODS: The primary CT data sets from previously treated left sided early breast cancer were used for pure volumetric arc therapy (VMAT) technique re-planning for the dosimetric characteristics comparison. A treatment plan of 3D-CRT hybrid VMAT technique was re-planned on the free breath (FB) condition for the investigation of the dosimetric characteristics comparison on DIBH condition. The prescribed dose for all the treatment plans was 42.5Gy in 16 fractions. All plans were optimized to cover 100% of the PTV by 95% of prescribed dose. The dosimetric differences among the 3 treatment plans for the 20 patients were analyzed using Wilcoxon signed-rank test, with p value<0.05 considered statistically significant. RESULTS: 3D-CRT hybrid VMAT using DIBH technique yielded the best results on the conformity index (CI) and homogeneity index (HI). By comparing this 3D-CRT hybrid VMAT technique using FB and DIBH technique, the mean heart dose (MHD) was reduced from 5.38Gy to 1.65Gy, respectively (p =0.001) and the left anterior descending coronary artery (LAD)0.03cc dose was reduced from 27.87Gy to 9.41Gy, respectively (p =0.001). 3D-CRT hybrid VMAT using DIBH technique significantly reduced the V5, V20 and D mean of the ipsilateral lung and D mean of the contralateral lung. The D5 of right breast was significantly reduced by 3D-CRT hybrid VMAT compared with VMAT using DIBH technique. CONCLUSION: The incorporation of DIBH into 3D-CRT hybrid VMAT technique provides the best benefits for the heart and the OAR with respect to the radiation dose-sparing effect without compromising the target conformity and homogeneity in the treatment planning. Dove 2023-10-12 /pmc/articles/PMC10578161/ /pubmed/37850030 http://dx.doi.org/10.2147/BCTT.S426903 Text en © 2023 Yeh and Lin. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Yeh, Hui-Ling Lin, Jia-Fu The Impact of Deep Inspiration Breath Hold (DIBH) Implementation on the Hybrid Technique in Left-Sided Whole Breast Irradiation: A Dosimetric Characteristic Study of 3D-CRT Hybrid VMAT in DIBH and Free Breathing Conditions, and VMAT in Free Breathing Conditions |
title | The Impact of Deep Inspiration Breath Hold (DIBH) Implementation on the Hybrid Technique in Left-Sided Whole Breast Irradiation: A Dosimetric Characteristic Study of 3D-CRT Hybrid VMAT in DIBH and Free Breathing Conditions, and VMAT in Free Breathing Conditions |
title_full | The Impact of Deep Inspiration Breath Hold (DIBH) Implementation on the Hybrid Technique in Left-Sided Whole Breast Irradiation: A Dosimetric Characteristic Study of 3D-CRT Hybrid VMAT in DIBH and Free Breathing Conditions, and VMAT in Free Breathing Conditions |
title_fullStr | The Impact of Deep Inspiration Breath Hold (DIBH) Implementation on the Hybrid Technique in Left-Sided Whole Breast Irradiation: A Dosimetric Characteristic Study of 3D-CRT Hybrid VMAT in DIBH and Free Breathing Conditions, and VMAT in Free Breathing Conditions |
title_full_unstemmed | The Impact of Deep Inspiration Breath Hold (DIBH) Implementation on the Hybrid Technique in Left-Sided Whole Breast Irradiation: A Dosimetric Characteristic Study of 3D-CRT Hybrid VMAT in DIBH and Free Breathing Conditions, and VMAT in Free Breathing Conditions |
title_short | The Impact of Deep Inspiration Breath Hold (DIBH) Implementation on the Hybrid Technique in Left-Sided Whole Breast Irradiation: A Dosimetric Characteristic Study of 3D-CRT Hybrid VMAT in DIBH and Free Breathing Conditions, and VMAT in Free Breathing Conditions |
title_sort | impact of deep inspiration breath hold (dibh) implementation on the hybrid technique in left-sided whole breast irradiation: a dosimetric characteristic study of 3d-crt hybrid vmat in dibh and free breathing conditions, and vmat in free breathing conditions |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10578161/ https://www.ncbi.nlm.nih.gov/pubmed/37850030 http://dx.doi.org/10.2147/BCTT.S426903 |
work_keys_str_mv | AT yehhuiling theimpactofdeepinspirationbreathholddibhimplementationonthehybridtechniqueinleftsidedwholebreastirradiationadosimetriccharacteristicstudyof3dcrthybridvmatindibhandfreebreathingconditionsandvmatinfreebreathingconditions AT linjiafu theimpactofdeepinspirationbreathholddibhimplementationonthehybridtechniqueinleftsidedwholebreastirradiationadosimetriccharacteristicstudyof3dcrthybridvmatindibhandfreebreathingconditionsandvmatinfreebreathingconditions AT yehhuiling impactofdeepinspirationbreathholddibhimplementationonthehybridtechniqueinleftsidedwholebreastirradiationadosimetriccharacteristicstudyof3dcrthybridvmatindibhandfreebreathingconditionsandvmatinfreebreathingconditions AT linjiafu impactofdeepinspirationbreathholddibhimplementationonthehybridtechniqueinleftsidedwholebreastirradiationadosimetriccharacteristicstudyof3dcrthybridvmatindibhandfreebreathingconditionsandvmatinfreebreathingconditions |