Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant

BACKGROUND: Patients with glaucoma on topical glaucoma medication are often affected by dry eye symptoms and thus likely to rub or squeeze their eyelids. Here, we telemetrically measure peak intraocular pressure (IOP) during eyelid manoeuvres and eyelid rubbing. METHODS: Eleven patients with primary...

Descripción completa

Detalles Bibliográficos
Autores principales: van den Bosch, Jacqueline J O N, Pennisi, Vincenzo, Mansouri, Kaweh, Weinreb, Robert N, Thieme, Hagen, Hoffmann, Michael B, Choritz, Lars
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10579178/
https://www.ncbi.nlm.nih.gov/pubmed/35701079
http://dx.doi.org/10.1136/bjophthalmol-2021-320508
_version_ 1785121669324472320
author van den Bosch, Jacqueline J O N
Pennisi, Vincenzo
Mansouri, Kaweh
Weinreb, Robert N
Thieme, Hagen
Hoffmann, Michael B
Choritz, Lars
author_facet van den Bosch, Jacqueline J O N
Pennisi, Vincenzo
Mansouri, Kaweh
Weinreb, Robert N
Thieme, Hagen
Hoffmann, Michael B
Choritz, Lars
author_sort van den Bosch, Jacqueline J O N
collection PubMed
description BACKGROUND: Patients with glaucoma on topical glaucoma medication are often affected by dry eye symptoms and thus likely to rub or squeeze their eyelids. Here, we telemetrically measure peak intraocular pressure (IOP) during eyelid manoeuvres and eyelid rubbing. METHODS: Eleven patients with primary open-angle glaucoma (POAG) previously implanted with a telemetric IOP sensor (Eyemate-IO) were instructed to look straight ahead for 1 min as a baseline measurement. Next, 6 repeats of blinking on instruction with 10 s intervals in between were performed. In addition, 5 repeats of eyelid closure (n=9), eyelid squeezing and eyelid rubbing (n=7) were performed with 15 s intervals in between. IOP was recorded via an external antenna placed around the study eye. Average peak IOP increases from baseline were analysed and tested against zero (no change) with one-sample t-tests. RESULTS: For eyelid rubbing, the average peak ∆ IOP increase (mean±SEM) was 59.1±9.6 mm Hg (p<0.001) from baseline. It was 42.2±5.8 mm Hg (p<0.0001) for eyelid squeezing, 3.8±0.6 mm Hg (n=9, p<0.01) for eyelid closure and 11.6±2.4 mm Hg (p<0.001) for voluntary blinking. No IOP change except for a short irregularity in the ocular pulse was observed during involuntary blinking. CONCLUSION: Eyelid manoeuvres in patients with POAG elicited brief increases in IOP that were particularly large with squeezing and rubbing. Further investigation of the potential implications for glaucoma progression is warranted.
format Online
Article
Text
id pubmed-10579178
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-105791782023-10-18 Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant van den Bosch, Jacqueline J O N Pennisi, Vincenzo Mansouri, Kaweh Weinreb, Robert N Thieme, Hagen Hoffmann, Michael B Choritz, Lars Br J Ophthalmol Clinical Science BACKGROUND: Patients with glaucoma on topical glaucoma medication are often affected by dry eye symptoms and thus likely to rub or squeeze their eyelids. Here, we telemetrically measure peak intraocular pressure (IOP) during eyelid manoeuvres and eyelid rubbing. METHODS: Eleven patients with primary open-angle glaucoma (POAG) previously implanted with a telemetric IOP sensor (Eyemate-IO) were instructed to look straight ahead for 1 min as a baseline measurement. Next, 6 repeats of blinking on instruction with 10 s intervals in between were performed. In addition, 5 repeats of eyelid closure (n=9), eyelid squeezing and eyelid rubbing (n=7) were performed with 15 s intervals in between. IOP was recorded via an external antenna placed around the study eye. Average peak IOP increases from baseline were analysed and tested against zero (no change) with one-sample t-tests. RESULTS: For eyelid rubbing, the average peak ∆ IOP increase (mean±SEM) was 59.1±9.6 mm Hg (p<0.001) from baseline. It was 42.2±5.8 mm Hg (p<0.0001) for eyelid squeezing, 3.8±0.6 mm Hg (n=9, p<0.01) for eyelid closure and 11.6±2.4 mm Hg (p<0.001) for voluntary blinking. No IOP change except for a short irregularity in the ocular pulse was observed during involuntary blinking. CONCLUSION: Eyelid manoeuvres in patients with POAG elicited brief increases in IOP that were particularly large with squeezing and rubbing. Further investigation of the potential implications for glaucoma progression is warranted. BMJ Publishing Group 2023-10 2022-06-14 /pmc/articles/PMC10579178/ /pubmed/35701079 http://dx.doi.org/10.1136/bjophthalmol-2021-320508 Text en © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Clinical Science
van den Bosch, Jacqueline J O N
Pennisi, Vincenzo
Mansouri, Kaweh
Weinreb, Robert N
Thieme, Hagen
Hoffmann, Michael B
Choritz, Lars
Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant
title Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant
title_full Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant
title_fullStr Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant
title_full_unstemmed Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant
title_short Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant
title_sort effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an iop sensor implant
topic Clinical Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10579178/
https://www.ncbi.nlm.nih.gov/pubmed/35701079
http://dx.doi.org/10.1136/bjophthalmol-2021-320508
work_keys_str_mv AT vandenboschjacquelinejon effectofeyelidmuscleactionandrubbingontelemetricallyobtainedintraocularpressureinpatientswithglaucomawithaniopsensorimplant
AT pennisivincenzo effectofeyelidmuscleactionandrubbingontelemetricallyobtainedintraocularpressureinpatientswithglaucomawithaniopsensorimplant
AT mansourikaweh effectofeyelidmuscleactionandrubbingontelemetricallyobtainedintraocularpressureinpatientswithglaucomawithaniopsensorimplant
AT weinrebrobertn effectofeyelidmuscleactionandrubbingontelemetricallyobtainedintraocularpressureinpatientswithglaucomawithaniopsensorimplant
AT thiemehagen effectofeyelidmuscleactionandrubbingontelemetricallyobtainedintraocularpressureinpatientswithglaucomawithaniopsensorimplant
AT hoffmannmichaelb effectofeyelidmuscleactionandrubbingontelemetricallyobtainedintraocularpressureinpatientswithglaucomawithaniopsensorimplant
AT choritzlars effectofeyelidmuscleactionandrubbingontelemetricallyobtainedintraocularpressureinpatientswithglaucomawithaniopsensorimplant