Cargando…

A high-speed current source for magnetorheological applications

Current source is an indispensable component of magnetorheological (MR) systems. Though MR fluid has a phase change as fast as in 1 ms, the response of MR damper (MRD) to generate the damping force may be two orders of magnitude longer. Therefore, the rapid response of current source is a key to rea...

Descripción completa

Detalles Bibliográficos
Autores principales: Xie, Lei, Lu, Chuan, Yin, Jianfei, Wei, Bo, Wang, Yuhao, Wang, Pengsai, Yang, Zhipeng, Liao, Changrong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10579296/
https://www.ncbi.nlm.nih.gov/pubmed/37845274
http://dx.doi.org/10.1038/s41598-023-43730-6
_version_ 1785121694728323072
author Xie, Lei
Lu, Chuan
Yin, Jianfei
Wei, Bo
Wang, Yuhao
Wang, Pengsai
Yang, Zhipeng
Liao, Changrong
author_facet Xie, Lei
Lu, Chuan
Yin, Jianfei
Wei, Bo
Wang, Yuhao
Wang, Pengsai
Yang, Zhipeng
Liao, Changrong
author_sort Xie, Lei
collection PubMed
description Current source is an indispensable component of magnetorheological (MR) systems. Though MR fluid has a phase change as fast as in 1 ms, the response of MR damper (MRD) to generate the damping force may be two orders of magnitude longer. Therefore, the rapid response of current source is a key to realize the real-time semi-active control of MR devices. This study proposes a programmable high-speed, low-cost current source exclusively for MR devices based on the synergy between supercapacitor and Buck converter (i.e., SSBC current source). SSBC current source features a strategy consisting of a lifting phase of supercapacitor and a following maintaining phase of Buck converter. Specifically, the high power density of supercapacitor contributes to rapidly lifting/raising the initial current, and then, like a “relay race”, the expected output is maintained through a Buck converter. Theoretical modeling and experiments are performed systematically. The response times (@ 95% of expected outputs) measured are 0.44, 0.84 and 1.88 ms for the outputs of 3, 6 and 9 A, respectively; these values are highlighted as the fastest level in this field. Besides, the response can be up to 24.6 and 43.7 times faster than the cases using supercapacitor and Buck converter to directly drive the MRD, respectively. SSBC current source is employed to generate a sequence of currents/magnetic inductions, only four variables of which need to be controlled programmatically: the order of lifting and maintaining phases, switching time of lifting phase, PWM duty cycle of Buck converter and duration of maintaining phase. The response time stability is verified by 100 cycles of on/off tests, showing a fluctuation of only 1.1%, which indicates a very reliable high-speed response. This study provides an exclusive power supply with a novel strategy for MR devices, which is believed to be an important promotion for MR technologies.
format Online
Article
Text
id pubmed-10579296
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-105792962023-10-18 A high-speed current source for magnetorheological applications Xie, Lei Lu, Chuan Yin, Jianfei Wei, Bo Wang, Yuhao Wang, Pengsai Yang, Zhipeng Liao, Changrong Sci Rep Article Current source is an indispensable component of magnetorheological (MR) systems. Though MR fluid has a phase change as fast as in 1 ms, the response of MR damper (MRD) to generate the damping force may be two orders of magnitude longer. Therefore, the rapid response of current source is a key to realize the real-time semi-active control of MR devices. This study proposes a programmable high-speed, low-cost current source exclusively for MR devices based on the synergy between supercapacitor and Buck converter (i.e., SSBC current source). SSBC current source features a strategy consisting of a lifting phase of supercapacitor and a following maintaining phase of Buck converter. Specifically, the high power density of supercapacitor contributes to rapidly lifting/raising the initial current, and then, like a “relay race”, the expected output is maintained through a Buck converter. Theoretical modeling and experiments are performed systematically. The response times (@ 95% of expected outputs) measured are 0.44, 0.84 and 1.88 ms for the outputs of 3, 6 and 9 A, respectively; these values are highlighted as the fastest level in this field. Besides, the response can be up to 24.6 and 43.7 times faster than the cases using supercapacitor and Buck converter to directly drive the MRD, respectively. SSBC current source is employed to generate a sequence of currents/magnetic inductions, only four variables of which need to be controlled programmatically: the order of lifting and maintaining phases, switching time of lifting phase, PWM duty cycle of Buck converter and duration of maintaining phase. The response time stability is verified by 100 cycles of on/off tests, showing a fluctuation of only 1.1%, which indicates a very reliable high-speed response. This study provides an exclusive power supply with a novel strategy for MR devices, which is believed to be an important promotion for MR technologies. Nature Publishing Group UK 2023-10-16 /pmc/articles/PMC10579296/ /pubmed/37845274 http://dx.doi.org/10.1038/s41598-023-43730-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Xie, Lei
Lu, Chuan
Yin, Jianfei
Wei, Bo
Wang, Yuhao
Wang, Pengsai
Yang, Zhipeng
Liao, Changrong
A high-speed current source for magnetorheological applications
title A high-speed current source for magnetorheological applications
title_full A high-speed current source for magnetorheological applications
title_fullStr A high-speed current source for magnetorheological applications
title_full_unstemmed A high-speed current source for magnetorheological applications
title_short A high-speed current source for magnetorheological applications
title_sort high-speed current source for magnetorheological applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10579296/
https://www.ncbi.nlm.nih.gov/pubmed/37845274
http://dx.doi.org/10.1038/s41598-023-43730-6
work_keys_str_mv AT xielei ahighspeedcurrentsourceformagnetorheologicalapplications
AT luchuan ahighspeedcurrentsourceformagnetorheologicalapplications
AT yinjianfei ahighspeedcurrentsourceformagnetorheologicalapplications
AT weibo ahighspeedcurrentsourceformagnetorheologicalapplications
AT wangyuhao ahighspeedcurrentsourceformagnetorheologicalapplications
AT wangpengsai ahighspeedcurrentsourceformagnetorheologicalapplications
AT yangzhipeng ahighspeedcurrentsourceformagnetorheologicalapplications
AT liaochangrong ahighspeedcurrentsourceformagnetorheologicalapplications
AT xielei highspeedcurrentsourceformagnetorheologicalapplications
AT luchuan highspeedcurrentsourceformagnetorheologicalapplications
AT yinjianfei highspeedcurrentsourceformagnetorheologicalapplications
AT weibo highspeedcurrentsourceformagnetorheologicalapplications
AT wangyuhao highspeedcurrentsourceformagnetorheologicalapplications
AT wangpengsai highspeedcurrentsourceformagnetorheologicalapplications
AT yangzhipeng highspeedcurrentsourceformagnetorheologicalapplications
AT liaochangrong highspeedcurrentsourceformagnetorheologicalapplications