Cargando…

The diagnostic utility of microscopic quality assessment of sputum samples in the era of rapid syndromic PCR testing

This prospective study assessed the value of initial microscopy evaluation of sputum samples submitted for rapid syndromic PCR-based testing. Bacterial detections by the BioFire FilmArray Pneumonia Panel plus in 126 high- and 108 low-quality sputum samples, based on initial microscopy evaluation in...

Descripción completa

Detalles Bibliográficos
Autores principales: Markussen, Dagfinn Lunde, Ebbesen, Marit, Serigstad, Sondre, Knoop, Siri Tandberg, Ritz, Christian, Bjørneklett, Rune, Kommedal, Øyvind, Jenum, Synne, Ulvestad, Elling, Grewal, Harleen M. S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10581175/
https://www.ncbi.nlm.nih.gov/pubmed/37772853
http://dx.doi.org/10.1128/spectrum.03002-23
_version_ 1785122084645502976
author Markussen, Dagfinn Lunde
Ebbesen, Marit
Serigstad, Sondre
Knoop, Siri Tandberg
Ritz, Christian
Bjørneklett, Rune
Kommedal, Øyvind
Jenum, Synne
Ulvestad, Elling
Grewal, Harleen M. S.
author_facet Markussen, Dagfinn Lunde
Ebbesen, Marit
Serigstad, Sondre
Knoop, Siri Tandberg
Ritz, Christian
Bjørneklett, Rune
Kommedal, Øyvind
Jenum, Synne
Ulvestad, Elling
Grewal, Harleen M. S.
author_sort Markussen, Dagfinn Lunde
collection PubMed
description This prospective study assessed the value of initial microscopy evaluation of sputum samples submitted for rapid syndromic PCR-based testing. Bacterial detections by the BioFire FilmArray Pneumonia Panel plus in 126 high- and 108 low-quality sputum samples, based on initial microscopy evaluation in samples from patients with lower respiratory tract infections were compared. We found that high-quality samples had a higher proportion of bacterial detections compared to low-quality samples (P = 0.013). This included a higher proportion of detections of bacteria deemed clinically relevant by predefined criteria (70% and 55%, P = 0.016), as well as a higher proportion of detections of Haemophilus influenzae (36% and 20%, P = 0.010). High-quality samples also had more detections of bacteria with high semi-quantitative values. The study found no significant difference between high- and low-quality samples in the proportions of samples with a single species of bacteria detected, samples with a bacteria treated by the clinician, samples with detection of a proven etiology of community-acquired pneumonia by predefined criteria, the number of bacterial species detected, or the detection of Streptococcus pneumoniae, Moraxella catarrhalis, or Staphylococcus aureus. The results showed that 40% (95% CI 35%–47%) of the bacterial detections would have been missed if only high-quality samples were analyzed. This included 41% (27%–56%) of detections of S. pneumoniae, 33% (23%–45%) of detections of H. influenzae, 42% (28%–58%) of detections of S. aureus, and 37% (23%–54%) of detections of M. catarrhalis. These findings suggest that all sputum samples submitted for rapid syndromic PCR testing should be analyzed, regardless of initial microscopy quality assessment. (This study has been registered at ClinicalTrials.gov under registration no. NCT04660084.) IMPORTANCE: Microscopic quality assessment of sputum samples was originally designed for sputum culture, and its applicability in today’s workflow, which includes syndromic PCR testing, may differ. Addressing this crucial gap, our study emphasizes the need to optimize the use and workflow of syndromic PCR panels, like the BioFire FilmArray Pneumonia plus (FAP plus), in microbiology laboratories. These advanced PCR-based tests offer rapid and comprehensive pathogen detection for respiratory infections, yet their full potential remains uncertain. By comparing bacterial detections in high- and low-quality sputum samples, we underscore the importance of including low-quality samples in testing. Our findings reveal a significant proportion of potentially clinically relevant bacterial detections that would have been missed if only high-quality samples were analyzed. These insights support the efficient implementation of syndromic PCR panels, ultimately enhancing patient care and outcomes.
format Online
Article
Text
id pubmed-10581175
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-105811752023-10-18 The diagnostic utility of microscopic quality assessment of sputum samples in the era of rapid syndromic PCR testing Markussen, Dagfinn Lunde Ebbesen, Marit Serigstad, Sondre Knoop, Siri Tandberg Ritz, Christian Bjørneklett, Rune Kommedal, Øyvind Jenum, Synne Ulvestad, Elling Grewal, Harleen M. S. Microbiol Spectr Research Article This prospective study assessed the value of initial microscopy evaluation of sputum samples submitted for rapid syndromic PCR-based testing. Bacterial detections by the BioFire FilmArray Pneumonia Panel plus in 126 high- and 108 low-quality sputum samples, based on initial microscopy evaluation in samples from patients with lower respiratory tract infections were compared. We found that high-quality samples had a higher proportion of bacterial detections compared to low-quality samples (P = 0.013). This included a higher proportion of detections of bacteria deemed clinically relevant by predefined criteria (70% and 55%, P = 0.016), as well as a higher proportion of detections of Haemophilus influenzae (36% and 20%, P = 0.010). High-quality samples also had more detections of bacteria with high semi-quantitative values. The study found no significant difference between high- and low-quality samples in the proportions of samples with a single species of bacteria detected, samples with a bacteria treated by the clinician, samples with detection of a proven etiology of community-acquired pneumonia by predefined criteria, the number of bacterial species detected, or the detection of Streptococcus pneumoniae, Moraxella catarrhalis, or Staphylococcus aureus. The results showed that 40% (95% CI 35%–47%) of the bacterial detections would have been missed if only high-quality samples were analyzed. This included 41% (27%–56%) of detections of S. pneumoniae, 33% (23%–45%) of detections of H. influenzae, 42% (28%–58%) of detections of S. aureus, and 37% (23%–54%) of detections of M. catarrhalis. These findings suggest that all sputum samples submitted for rapid syndromic PCR testing should be analyzed, regardless of initial microscopy quality assessment. (This study has been registered at ClinicalTrials.gov under registration no. NCT04660084.) IMPORTANCE: Microscopic quality assessment of sputum samples was originally designed for sputum culture, and its applicability in today’s workflow, which includes syndromic PCR testing, may differ. Addressing this crucial gap, our study emphasizes the need to optimize the use and workflow of syndromic PCR panels, like the BioFire FilmArray Pneumonia plus (FAP plus), in microbiology laboratories. These advanced PCR-based tests offer rapid and comprehensive pathogen detection for respiratory infections, yet their full potential remains uncertain. By comparing bacterial detections in high- and low-quality sputum samples, we underscore the importance of including low-quality samples in testing. Our findings reveal a significant proportion of potentially clinically relevant bacterial detections that would have been missed if only high-quality samples were analyzed. These insights support the efficient implementation of syndromic PCR panels, ultimately enhancing patient care and outcomes. American Society for Microbiology 2023-09-29 /pmc/articles/PMC10581175/ /pubmed/37772853 http://dx.doi.org/10.1128/spectrum.03002-23 Text en Copyright © 2023 Markussen et al. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Markussen, Dagfinn Lunde
Ebbesen, Marit
Serigstad, Sondre
Knoop, Siri Tandberg
Ritz, Christian
Bjørneklett, Rune
Kommedal, Øyvind
Jenum, Synne
Ulvestad, Elling
Grewal, Harleen M. S.
The diagnostic utility of microscopic quality assessment of sputum samples in the era of rapid syndromic PCR testing
title The diagnostic utility of microscopic quality assessment of sputum samples in the era of rapid syndromic PCR testing
title_full The diagnostic utility of microscopic quality assessment of sputum samples in the era of rapid syndromic PCR testing
title_fullStr The diagnostic utility of microscopic quality assessment of sputum samples in the era of rapid syndromic PCR testing
title_full_unstemmed The diagnostic utility of microscopic quality assessment of sputum samples in the era of rapid syndromic PCR testing
title_short The diagnostic utility of microscopic quality assessment of sputum samples in the era of rapid syndromic PCR testing
title_sort diagnostic utility of microscopic quality assessment of sputum samples in the era of rapid syndromic pcr testing
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10581175/
https://www.ncbi.nlm.nih.gov/pubmed/37772853
http://dx.doi.org/10.1128/spectrum.03002-23
work_keys_str_mv AT markussendagfinnlunde thediagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT ebbesenmarit thediagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT serigstadsondre thediagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT knoopsiritandberg thediagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT ritzchristian thediagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT bjørneklettrune thediagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT kommedaløyvind thediagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT jenumsynne thediagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT ulvestadelling thediagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT grewalharleenms thediagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT markussendagfinnlunde diagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT ebbesenmarit diagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT serigstadsondre diagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT knoopsiritandberg diagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT ritzchristian diagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT bjørneklettrune diagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT kommedaløyvind diagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT jenumsynne diagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT ulvestadelling diagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting
AT grewalharleenms diagnosticutilityofmicroscopicqualityassessmentofsputumsamplesintheeraofrapidsyndromicpcrtesting