Effects of CPAP and FiO(2) on respiratory effort and lung stress in early COVID-19 pneumonia: a randomized, crossover study
BACKGROUND: in COVID-19 acute respiratory failure, the effects of CPAP and FiO(2) on respiratory effort and lung stress are unclear. We hypothesize that, in the compliant lungs of early Sars-CoV-2 pneumonia, the application of positive pressure through Helmet-CPAP may not decrease respiratory effort...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10581975/ https://www.ncbi.nlm.nih.gov/pubmed/37847454 http://dx.doi.org/10.1186/s13613-023-01202-0 |
_version_ | 1785122229195898880 |
---|---|
author | Giosa, Lorenzo Collins, Patrick Duncan Sciolla, Martina Cerrone, Francesca Di Blasi, Salvatore Macrì, Matteo Maria Davicco, Luca Laguzzi, Andrea Gorgonzola, Fabiana Penso, Roberto Steinberg, Irene Muraccini, Massimo Perboni, Alberto Russotto, Vincenzo Camporota, Luigi Bellani, Giacomo Caironi, Pietro |
author_facet | Giosa, Lorenzo Collins, Patrick Duncan Sciolla, Martina Cerrone, Francesca Di Blasi, Salvatore Macrì, Matteo Maria Davicco, Luca Laguzzi, Andrea Gorgonzola, Fabiana Penso, Roberto Steinberg, Irene Muraccini, Massimo Perboni, Alberto Russotto, Vincenzo Camporota, Luigi Bellani, Giacomo Caironi, Pietro |
author_sort | Giosa, Lorenzo |
collection | PubMed |
description | BACKGROUND: in COVID-19 acute respiratory failure, the effects of CPAP and FiO(2) on respiratory effort and lung stress are unclear. We hypothesize that, in the compliant lungs of early Sars-CoV-2 pneumonia, the application of positive pressure through Helmet-CPAP may not decrease respiratory effort, and rather worsen lung stress and oxygenation when compared to higher FiO(2) delivered via oxygen masks. METHODS: In this single-center (S.Luigi Gonzaga University-Hospital, Turin, Italy), randomized, crossover study, we included patients receiving Helmet-CPAP for early (< 48 h) COVID-19 pneumonia without additional cardiac or respiratory disease. Healthy subjects were included as controls. Participants were equipped with an esophageal catheter, a non-invasive cardiac output monitor, and an arterial catheter. The protocol consisted of a random sequence of non-rebreather mask (NRB), Helmet-CPAP (with variable positive pressure and FiO(2)) and Venturi mask (FiO(2) 0.5), each delivered for 20 min. Study outcomes were changes in respiratory effort (esophageal swing), total lung stress (dynamic + static transpulmonary pressure), gas-exchange and hemodynamics. RESULTS: We enrolled 28 COVID-19 patients and 7 healthy controls. In all patients, respiratory effort increased from NRB to Helmet-CPAP (5.0 ± 3.7 vs 8.3 ± 3.9 cmH(2)O, p < 0.01). However, Helmet’s pressure decreased by a comparable amount during inspiration (− 3.1 ± 1.0 cmH(2)O, p = 0.16), therefore dynamic stress remained stable (p = 0.97). Changes in static and total lung stress from NRB to Helmet-CPAP were overall not significant (p = 0.07 and p = 0.09, respectively), but showed high interpatient variability, ranging from − 4.5 to + 6.1 cmH(2)O, and from − 5.8 to + 5.7 cmH(2)O, respectively. All findings were confirmed in healthy subjects, except for an increase in dynamic stress (p < 0.01). PaO(2) decreased from NRB to Helmet-CPAP with FiO(2) 0.5 (107 ± 55 vs 86 ± 30 mmHg, p < 0.01), irrespective of positive pressure levels (p = 0.64). Conversely, with Helmet’s FiO(2) 0.9, PaO(2) increased (p < 0.01), but oxygen delivery remained stable (p = 0.48) as cardiac output decreased (p = 0.02). When PaO(2) fell below 60 mmHg with VM, respiratory effort increased proportionally (p < 0.01, r = 0.81). CONCLUSIONS: In early COVID-19 pneumonia, Helmet-CPAP increases respiratory effort without altering dynamic stress, while the effects upon static and total stress are variable, requiring individual assessment. Oxygen masks with higher FiO(2) provide better oxygenation with lower respiratory effort. Trial registration Retrospectively registered (13-May-2021): clinicaltrials.gov (NCT04885517), https://clinicaltrials.gov/ct2/show/NCT04885517. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13613-023-01202-0. |
format | Online Article Text |
id | pubmed-10581975 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-105819752023-10-19 Effects of CPAP and FiO(2) on respiratory effort and lung stress in early COVID-19 pneumonia: a randomized, crossover study Giosa, Lorenzo Collins, Patrick Duncan Sciolla, Martina Cerrone, Francesca Di Blasi, Salvatore Macrì, Matteo Maria Davicco, Luca Laguzzi, Andrea Gorgonzola, Fabiana Penso, Roberto Steinberg, Irene Muraccini, Massimo Perboni, Alberto Russotto, Vincenzo Camporota, Luigi Bellani, Giacomo Caironi, Pietro Ann Intensive Care Research BACKGROUND: in COVID-19 acute respiratory failure, the effects of CPAP and FiO(2) on respiratory effort and lung stress are unclear. We hypothesize that, in the compliant lungs of early Sars-CoV-2 pneumonia, the application of positive pressure through Helmet-CPAP may not decrease respiratory effort, and rather worsen lung stress and oxygenation when compared to higher FiO(2) delivered via oxygen masks. METHODS: In this single-center (S.Luigi Gonzaga University-Hospital, Turin, Italy), randomized, crossover study, we included patients receiving Helmet-CPAP for early (< 48 h) COVID-19 pneumonia without additional cardiac or respiratory disease. Healthy subjects were included as controls. Participants were equipped with an esophageal catheter, a non-invasive cardiac output monitor, and an arterial catheter. The protocol consisted of a random sequence of non-rebreather mask (NRB), Helmet-CPAP (with variable positive pressure and FiO(2)) and Venturi mask (FiO(2) 0.5), each delivered for 20 min. Study outcomes were changes in respiratory effort (esophageal swing), total lung stress (dynamic + static transpulmonary pressure), gas-exchange and hemodynamics. RESULTS: We enrolled 28 COVID-19 patients and 7 healthy controls. In all patients, respiratory effort increased from NRB to Helmet-CPAP (5.0 ± 3.7 vs 8.3 ± 3.9 cmH(2)O, p < 0.01). However, Helmet’s pressure decreased by a comparable amount during inspiration (− 3.1 ± 1.0 cmH(2)O, p = 0.16), therefore dynamic stress remained stable (p = 0.97). Changes in static and total lung stress from NRB to Helmet-CPAP were overall not significant (p = 0.07 and p = 0.09, respectively), but showed high interpatient variability, ranging from − 4.5 to + 6.1 cmH(2)O, and from − 5.8 to + 5.7 cmH(2)O, respectively. All findings were confirmed in healthy subjects, except for an increase in dynamic stress (p < 0.01). PaO(2) decreased from NRB to Helmet-CPAP with FiO(2) 0.5 (107 ± 55 vs 86 ± 30 mmHg, p < 0.01), irrespective of positive pressure levels (p = 0.64). Conversely, with Helmet’s FiO(2) 0.9, PaO(2) increased (p < 0.01), but oxygen delivery remained stable (p = 0.48) as cardiac output decreased (p = 0.02). When PaO(2) fell below 60 mmHg with VM, respiratory effort increased proportionally (p < 0.01, r = 0.81). CONCLUSIONS: In early COVID-19 pneumonia, Helmet-CPAP increases respiratory effort without altering dynamic stress, while the effects upon static and total stress are variable, requiring individual assessment. Oxygen masks with higher FiO(2) provide better oxygenation with lower respiratory effort. Trial registration Retrospectively registered (13-May-2021): clinicaltrials.gov (NCT04885517), https://clinicaltrials.gov/ct2/show/NCT04885517. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13613-023-01202-0. Springer International Publishing 2023-10-17 /pmc/articles/PMC10581975/ /pubmed/37847454 http://dx.doi.org/10.1186/s13613-023-01202-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Giosa, Lorenzo Collins, Patrick Duncan Sciolla, Martina Cerrone, Francesca Di Blasi, Salvatore Macrì, Matteo Maria Davicco, Luca Laguzzi, Andrea Gorgonzola, Fabiana Penso, Roberto Steinberg, Irene Muraccini, Massimo Perboni, Alberto Russotto, Vincenzo Camporota, Luigi Bellani, Giacomo Caironi, Pietro Effects of CPAP and FiO(2) on respiratory effort and lung stress in early COVID-19 pneumonia: a randomized, crossover study |
title | Effects of CPAP and FiO(2) on respiratory effort and lung stress in early COVID-19 pneumonia: a randomized, crossover study |
title_full | Effects of CPAP and FiO(2) on respiratory effort and lung stress in early COVID-19 pneumonia: a randomized, crossover study |
title_fullStr | Effects of CPAP and FiO(2) on respiratory effort and lung stress in early COVID-19 pneumonia: a randomized, crossover study |
title_full_unstemmed | Effects of CPAP and FiO(2) on respiratory effort and lung stress in early COVID-19 pneumonia: a randomized, crossover study |
title_short | Effects of CPAP and FiO(2) on respiratory effort and lung stress in early COVID-19 pneumonia: a randomized, crossover study |
title_sort | effects of cpap and fio(2) on respiratory effort and lung stress in early covid-19 pneumonia: a randomized, crossover study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10581975/ https://www.ncbi.nlm.nih.gov/pubmed/37847454 http://dx.doi.org/10.1186/s13613-023-01202-0 |
work_keys_str_mv | AT giosalorenzo effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT collinspatrickduncan effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT sciollamartina effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT cerronefrancesca effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT diblasisalvatore effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT macrimatteomaria effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT daviccoluca effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT laguzziandrea effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT gorgonzolafabiana effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT pensoroberto effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT steinbergirene effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT muraccinimassimo effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT perbonialberto effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT russottovincenzo effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT camporotaluigi effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT bellanigiacomo effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy AT caironipietro effectsofcpapandfio2onrespiratoryeffortandlungstressinearlycovid19pneumoniaarandomizedcrossoverstudy |