Cargando…

Self-assembled porous polymer films for improved oxygen sensing

Absolute oxygen sensors based on quenching of phosphorescence have been the subject of numerous studies for the monitoring of biological environments. Here, we used simple fabrication techniques with readily available polymers to obtain high performance phosphorescent films. Specifically, evaporatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Salaris, Nikolaos, Haigh, Paul, Papakonstantinou, Ioannis, Tiwari, Manish K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Sequoia 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10582206/
https://www.ncbi.nlm.nih.gov/pubmed/37859642
http://dx.doi.org/10.1016/j.snb.2022.132794
_version_ 1785122277210193920
author Salaris, Nikolaos
Haigh, Paul
Papakonstantinou, Ioannis
Tiwari, Manish K.
author_facet Salaris, Nikolaos
Haigh, Paul
Papakonstantinou, Ioannis
Tiwari, Manish K.
author_sort Salaris, Nikolaos
collection PubMed
description Absolute oxygen sensors based on quenching of phosphorescence have been the subject of numerous studies for the monitoring of biological environments. Here, we used simple fabrication techniques with readily available polymers to obtain high performance phosphorescent films. Specifically, evaporation-based phase separation and the breath figure technique were used to induce porosity. The pore sizes ranged from [Formula: see text] 37 nm to [Formula: see text] 141 [Formula: see text] m while the maximum average porosity achieved was [Formula: see text] 74%. The oxygen sensing properties were evaluated via a standarised calibration procedure with an optoelectronic setup in both transmission and reflection based configurations. When comparing non-porous and porous films, the highest improvements achieved were a factor of [Formula: see text] 7.9 in dynamic range and [Formula: see text] 7.3 in maximum sensitivity, followed by an improved linearity with a half-sensitivity point at 43% O [Formula: see text] V/V. Also, the recovery time was reduced by an order of magnitude in the high porosity film and all samples prepared were not affected by variations in the humidity of the surrounding environment. Despite the use of common polymers, the fabrication techniques employed led to the significant enhancement of oxygen sensing properties and elucidated the relation between porous film morphologies and sensing performance.
format Online
Article
Text
id pubmed-10582206
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier Sequoia
record_format MEDLINE/PubMed
spelling pubmed-105822062023-10-19 Self-assembled porous polymer films for improved oxygen sensing Salaris, Nikolaos Haigh, Paul Papakonstantinou, Ioannis Tiwari, Manish K. Sens Actuators B Chem Article Absolute oxygen sensors based on quenching of phosphorescence have been the subject of numerous studies for the monitoring of biological environments. Here, we used simple fabrication techniques with readily available polymers to obtain high performance phosphorescent films. Specifically, evaporation-based phase separation and the breath figure technique were used to induce porosity. The pore sizes ranged from [Formula: see text] 37 nm to [Formula: see text] 141 [Formula: see text] m while the maximum average porosity achieved was [Formula: see text] 74%. The oxygen sensing properties were evaluated via a standarised calibration procedure with an optoelectronic setup in both transmission and reflection based configurations. When comparing non-porous and porous films, the highest improvements achieved were a factor of [Formula: see text] 7.9 in dynamic range and [Formula: see text] 7.3 in maximum sensitivity, followed by an improved linearity with a half-sensitivity point at 43% O [Formula: see text] V/V. Also, the recovery time was reduced by an order of magnitude in the high porosity film and all samples prepared were not affected by variations in the humidity of the surrounding environment. Despite the use of common polymers, the fabrication techniques employed led to the significant enhancement of oxygen sensing properties and elucidated the relation between porous film morphologies and sensing performance. Elsevier Sequoia 2023-01-01 /pmc/articles/PMC10582206/ /pubmed/37859642 http://dx.doi.org/10.1016/j.snb.2022.132794 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Salaris, Nikolaos
Haigh, Paul
Papakonstantinou, Ioannis
Tiwari, Manish K.
Self-assembled porous polymer films for improved oxygen sensing
title Self-assembled porous polymer films for improved oxygen sensing
title_full Self-assembled porous polymer films for improved oxygen sensing
title_fullStr Self-assembled porous polymer films for improved oxygen sensing
title_full_unstemmed Self-assembled porous polymer films for improved oxygen sensing
title_short Self-assembled porous polymer films for improved oxygen sensing
title_sort self-assembled porous polymer films for improved oxygen sensing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10582206/
https://www.ncbi.nlm.nih.gov/pubmed/37859642
http://dx.doi.org/10.1016/j.snb.2022.132794
work_keys_str_mv AT salarisnikolaos selfassembledporouspolymerfilmsforimprovedoxygensensing
AT haighpaul selfassembledporouspolymerfilmsforimprovedoxygensensing
AT papakonstantinouioannis selfassembledporouspolymerfilmsforimprovedoxygensensing
AT tiwarimanishk selfassembledporouspolymerfilmsforimprovedoxygensensing