Cargando…

Modelling and correcting the impact of RF pulses for continuous monitoring of hyperpolarized NMR

Monitoring the build-up or decay of hyperpolarization in nuclear magnetic resonance requires radio-frequency (RF) pulses to generate observable nuclear magnetization. However, the pulses also lead to a depletion of the polarization and, thus, alter the spin dynamics. To simulate the effects of RF pu...

Descripción completa

Detalles Bibliográficos
Autores principales: von Witte, Gevin, Ernst, Matthias, Kozerke, Sebastian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Copernicus GmbH 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10583294/
https://www.ncbi.nlm.nih.gov/pubmed/37904858
http://dx.doi.org/10.5194/mr-4-175-2023
Descripción
Sumario:Monitoring the build-up or decay of hyperpolarization in nuclear magnetic resonance requires radio-frequency (RF) pulses to generate observable nuclear magnetization. However, the pulses also lead to a depletion of the polarization and, thus, alter the spin dynamics. To simulate the effects of RF pulses on the polarization build-up and decay, we propose a first-order rate-equation model describing the dynamics of the hyperpolarization process through a single source and a relaxation term. The model offers a direct interpretation of the measured steady-state polarization and build-up time constant. Furthermore, the rate-equation model is used to study three different methods to correct the errors introduced by RF pulses: (i) a [Formula: see text] correction ( [Formula: see text] denoting the RF pulse flip angle), which is only applicable to decays; (ii) an analytical model introduced previously in the literature; and (iii) an iterative correction approach proposed here. The three correction methods are compared using simulated data for a range of RF flip angles and RF repetition times. The correction methods are also tested on experimental data obtained with dynamic nuclear polarization (DNP) using 4-oxo-TEMPO in [Formula: see text] H glassy matrices. It is demonstrated that the analytical and iterative corrections allow us to obtain accurate build-up times and steady-state polarizations (enhancements) for RF flip angles of up to 25 [Formula: see text] during the polarization build-up process within [Formula: see text]  % error when compared to data acquired with small RF flip angles ( [Formula: see text] [Formula: see text] ). For polarization decay experiments, corrections are shown to be accurate for RF flip angles of up to 12 [Formula: see text] . In conclusion, the proposed iterative correction allows us to compensate for the impact of RF pulses offering an accurate estimation of polarization levels, build-up and decay time constants in hyperpolarization experiments.