Cargando…
Assessment of the Cepheid 3-gene Host Response Fingerstick Blood Test (MTB-HR) on rapid diagnosis of tuberculosis
The World Health Organization has identified high-priority target product profiles for new TB diagnostics which include rapid biomarker-based, non-sputum-based diagnostic testing, using an easily accessible sample. The Cepheid 3-gene Host Response Fingerstick Blood Prototype Test (MTB-HR) quantifies...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10583623/ https://www.ncbi.nlm.nih.gov/pubmed/37848021 http://dx.doi.org/10.1080/22221751.2023.2261561 |
Sumario: | The World Health Organization has identified high-priority target product profiles for new TB diagnostics which include rapid biomarker-based, non-sputum-based diagnostic testing, using an easily accessible sample. The Cepheid 3-gene Host Response Fingerstick Blood Prototype Test (MTB-HR) quantifies relative mRNA levels of a 3-gene signature (GBP5, DUSP3, and KLF2) from a whole-blood sample on the GeneXpert platform. The objective of the present study was to evaluate the performance of the MTB-HR to distinguish between active tuberculosis (ATB), latent Mycobacterium tuberculosis infection (LTBI), other pulmonary diseases, and healthy volunteers at a tertiary care centre. Among 653 participants enrolled in this study, 192 were diagnosed as having ATB, and the remaining 461 were classified as non-ATB, including 137 cases of LTBI, 224 cases of other pulmonary diseases, and 100 healthy volunteers. The corresponding AUCs of the MTB-HR in distinguishing untreated ATB from non-ATB, LTBI, other pulmonary diseases, and healthy volunteers were 0.814 (95% CI, 0.760-0.868, sensitivity 76.1%, specificity 71.6%), 0.739 (95% CI, 0.667-0.812, sensitivity 59.7%, specificity 78.1%), 0.825 (95% CI, 0.770-0.880, sensitivity 82.1%, specificity 65.6%), 0.892 (95% CI, 0.839-0.945, sensitivity 76.1%, specificity 88.0%), respectively. When only samples with TAT of less than 1 h were included, the AUC of the MTB-HR in distinguishing untreated ATB from non-ATB was largest, 0.920 (95% CI, 0.822-1.000, sensitivity 81.3%, specificity 87.7%). In conclusion, the MTB-HR assay shows potential as a rapid, blood-based screening and triage test for ATB, especially for untreated ATB, with the advantage of increased diagnostic yield since blood is more readily available. |
---|