Cargando…

Quantitative (177)Lu SPECT/CT imaging for personalized dosimetry using a ring-shaped CZT-based camera

BACKGROUND: Dosimetry after radiopharmaceutical therapy with (177)Lu ((177)Lu-RPT) relies on quantitative SPECT/CT imaging, for which suitable reconstruction protocols are required. In this study, we characterized for the first time the quantitative performance of a ring-shaped CZT-based camera usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Danieli, Rachele, Stella, Martina, Leube, Julian, Tran-Gia, Johannes, Marin, Clementine, Uribe, Carlos F., Vanderlinden, Bruno, Reynaert, Nick, Flamen, Patrick, Levillain, Hugo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10584798/
https://www.ncbi.nlm.nih.gov/pubmed/37853247
http://dx.doi.org/10.1186/s40658-023-00586-z
Descripción
Sumario:BACKGROUND: Dosimetry after radiopharmaceutical therapy with (177)Lu ((177)Lu-RPT) relies on quantitative SPECT/CT imaging, for which suitable reconstruction protocols are required. In this study, we characterized for the first time the quantitative performance of a ring-shaped CZT-based camera using two different reconstruction algorithms: an ordered subset expectation maximization (OSEM) and a block sequential regularized expectation maximization (BSREM) combined with noise reduction regularization. This study lays the foundations for the definition of a reconstruction protocol enabling accurate dosimetry for patients treated with (177)Lu-RPT. METHODS: A series of (177)Lu-filled phantoms were acquired on a StarGuide™ (GE HealthCare), with energy and scatter windows centred at 208 (± 6%) keV and 185 (± 5%) keV, respectively. Images were reconstructed with the manufacturer implementations of OSEM (GE-OSEM) and BSREM (Q.Clear) algorithms, and various combinations of iterations and subsets. Additionally, the manufacturer-recommended Q.Clear-based reconstruction protocol was evaluated. Quantification accuracy, measured as the difference between the SPECT-based and the radionuclide calibrator-based activity, and noise were evaluated in a large cylinder. Recovery coefficients (RCs) and spatial resolution were assessed in a NEMA IEC phantom with sphere inserts. The reconstruction protocols considered suitable for clinical applications were tested on a cohort of patients treated with [(177)Lu]Lu-PSMA-I&T. RESULTS: The accuracy of the activity from the cylinder, although affected by septal penetration, was < 10% for all reconstructions. Both algorithms featured improved spatial resolution and higher RCs with increasing updates at the cost of noise build-up, but Q.Clear outperformed GE-OSEM in reducing noise accumulation. When the reconstruction parameters were carefully selected, similar values for noise (~0.15), spatial resolution (~1 cm) and RCs were found, irrespective of the reconstruction algorithm. Analogue results were found in patients. CONCLUSIONS: Accurate activity quantification is possible when imaging (177)Lu with StarGuide™. However, the impact of septal penetration requires further investigations. GE-OSEM is a valid alternative to the recommended Q.Clear reconstruction algorithm, featuring comparable performances assessed on phantoms and patients. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40658-023-00586-z.