Cargando…

Simultaneous percutaneous microwave ablation and biopsy for highly suspected malignant pulmonary nodules: a retrospective cohort study

BACKGROUND: The conventional diagnosis and treatment for highly suspected malignant pulmonary nodules (PNs) can avoid unnecessary treatment to some extent. However, the relatively separate puncture processes may not only increase puncture-related complications, but also increase the patient’s radiat...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Jianxiang, Xu, Kaihao, Du, Kepu, Han, Xinwei, Jiao, Dechao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10585563/
https://www.ncbi.nlm.nih.gov/pubmed/37869271
http://dx.doi.org/10.21037/qims-23-138
_version_ 1785122981530304512
author Zhang, Jianxiang
Xu, Kaihao
Du, Kepu
Han, Xinwei
Jiao, Dechao
author_facet Zhang, Jianxiang
Xu, Kaihao
Du, Kepu
Han, Xinwei
Jiao, Dechao
author_sort Zhang, Jianxiang
collection PubMed
description BACKGROUND: The conventional diagnosis and treatment for highly suspected malignant pulmonary nodules (PNs) can avoid unnecessary treatment to some extent. However, the relatively separate puncture processes may not only increase puncture-related complications, but also increase the patient’s radiation exposure and hospitalization costs. The purpose of this study was to retrospectively analyze the effectiveness of simultaneous percutaneous microwave ablation (MWA) and percutaneous biopsy (PB) for PNs. METHODS: From August 2015 to August 2022, 65 consecutive patients [48 solid nodules, 6 ground glass opacities (GGOs), 11 mixed nodules] with suspected single malignant PN underwent MWA and PB combination treatments at the First Affiliated Hospital of Zhengzhou University. The total of 30 patients in Group A underwent synchronous PB and MWA (strategy: low-power MWA-PB-high-power MWA), whereas 35 patients in Group B underwent asynchronous PB and MWA. The technical success, complete ablation (CA), complications, total procedure time (TPT), patient exposure dose (PED), hospitalization time, and costs were compared. An independent samples t-, χ(2), or Fisher’s exact tests were used. RESULTS: The technical success (100% vs. 100%) and CA (100% vs. 97.1%) rates were not significantly different between Groups A and B. The complications of intrapulmonary hemorrhage (16.7% vs. 41.4%, P=0.02) and hemoptysis (0% vs. 8.6%, P=0.04) were significantly different between Groups A and B. TPT (41.6±7.9 vs. 57.3±8.8 min, P<0.001), PED (12.9±1.4 vs. 19.4±2.3 mSv, P<0.001), hospitalization stay (4.7±1.3 vs. 9.1±2.1 days, P<0.001) and costs (3,768.8±652.9 vs. 4,508.0±514.1 USD, P<0.001) also showed significant differences between Groups A and B. CONCLUSIONS: Synchronous PB and MWA for PNs is a safe and effective strategy that can decrease bleeding, PED, the hospitalization stay, and costs.
format Online
Article
Text
id pubmed-10585563
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-105855632023-10-20 Simultaneous percutaneous microwave ablation and biopsy for highly suspected malignant pulmonary nodules: a retrospective cohort study Zhang, Jianxiang Xu, Kaihao Du, Kepu Han, Xinwei Jiao, Dechao Quant Imaging Med Surg Original Article BACKGROUND: The conventional diagnosis and treatment for highly suspected malignant pulmonary nodules (PNs) can avoid unnecessary treatment to some extent. However, the relatively separate puncture processes may not only increase puncture-related complications, but also increase the patient’s radiation exposure and hospitalization costs. The purpose of this study was to retrospectively analyze the effectiveness of simultaneous percutaneous microwave ablation (MWA) and percutaneous biopsy (PB) for PNs. METHODS: From August 2015 to August 2022, 65 consecutive patients [48 solid nodules, 6 ground glass opacities (GGOs), 11 mixed nodules] with suspected single malignant PN underwent MWA and PB combination treatments at the First Affiliated Hospital of Zhengzhou University. The total of 30 patients in Group A underwent synchronous PB and MWA (strategy: low-power MWA-PB-high-power MWA), whereas 35 patients in Group B underwent asynchronous PB and MWA. The technical success, complete ablation (CA), complications, total procedure time (TPT), patient exposure dose (PED), hospitalization time, and costs were compared. An independent samples t-, χ(2), or Fisher’s exact tests were used. RESULTS: The technical success (100% vs. 100%) and CA (100% vs. 97.1%) rates were not significantly different between Groups A and B. The complications of intrapulmonary hemorrhage (16.7% vs. 41.4%, P=0.02) and hemoptysis (0% vs. 8.6%, P=0.04) were significantly different between Groups A and B. TPT (41.6±7.9 vs. 57.3±8.8 min, P<0.001), PED (12.9±1.4 vs. 19.4±2.3 mSv, P<0.001), hospitalization stay (4.7±1.3 vs. 9.1±2.1 days, P<0.001) and costs (3,768.8±652.9 vs. 4,508.0±514.1 USD, P<0.001) also showed significant differences between Groups A and B. CONCLUSIONS: Synchronous PB and MWA for PNs is a safe and effective strategy that can decrease bleeding, PED, the hospitalization stay, and costs. AME Publishing Company 2023-09-07 2023-10-01 /pmc/articles/PMC10585563/ /pubmed/37869271 http://dx.doi.org/10.21037/qims-23-138 Text en 2023 Quantitative Imaging in Medicine and Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Zhang, Jianxiang
Xu, Kaihao
Du, Kepu
Han, Xinwei
Jiao, Dechao
Simultaneous percutaneous microwave ablation and biopsy for highly suspected malignant pulmonary nodules: a retrospective cohort study
title Simultaneous percutaneous microwave ablation and biopsy for highly suspected malignant pulmonary nodules: a retrospective cohort study
title_full Simultaneous percutaneous microwave ablation and biopsy for highly suspected malignant pulmonary nodules: a retrospective cohort study
title_fullStr Simultaneous percutaneous microwave ablation and biopsy for highly suspected malignant pulmonary nodules: a retrospective cohort study
title_full_unstemmed Simultaneous percutaneous microwave ablation and biopsy for highly suspected malignant pulmonary nodules: a retrospective cohort study
title_short Simultaneous percutaneous microwave ablation and biopsy for highly suspected malignant pulmonary nodules: a retrospective cohort study
title_sort simultaneous percutaneous microwave ablation and biopsy for highly suspected malignant pulmonary nodules: a retrospective cohort study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10585563/
https://www.ncbi.nlm.nih.gov/pubmed/37869271
http://dx.doi.org/10.21037/qims-23-138
work_keys_str_mv AT zhangjianxiang simultaneouspercutaneousmicrowaveablationandbiopsyforhighlysuspectedmalignantpulmonarynodulesaretrospectivecohortstudy
AT xukaihao simultaneouspercutaneousmicrowaveablationandbiopsyforhighlysuspectedmalignantpulmonarynodulesaretrospectivecohortstudy
AT dukepu simultaneouspercutaneousmicrowaveablationandbiopsyforhighlysuspectedmalignantpulmonarynodulesaretrospectivecohortstudy
AT hanxinwei simultaneouspercutaneousmicrowaveablationandbiopsyforhighlysuspectedmalignantpulmonarynodulesaretrospectivecohortstudy
AT jiaodechao simultaneouspercutaneousmicrowaveablationandbiopsyforhighlysuspectedmalignantpulmonarynodulesaretrospectivecohortstudy