Cargando…

Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings

BACKGROUND: This study was to prospectively investigate the feasibility of four-dimensional computed tomography angiography (4D-CTA) with electrocardiogram-gated (ECG) reconstruction for preoperative evaluation of morphological parameters, and compared with digital subtraction angiography (DSA). We...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Liping, Gao, Xing, Gao, Chao, Xu, Shichuan, Cao, Shaodong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10585900/
https://www.ncbi.nlm.nih.gov/pubmed/37853358
http://dx.doi.org/10.1186/s12880-023-01107-1
_version_ 1785123046193889280
author Yang, Liping
Gao, Xing
Gao, Chao
Xu, Shichuan
Cao, Shaodong
author_facet Yang, Liping
Gao, Xing
Gao, Chao
Xu, Shichuan
Cao, Shaodong
author_sort Yang, Liping
collection PubMed
description BACKGROUND: This study was to prospectively investigate the feasibility of four-dimensional computed tomography angiography (4D-CTA) with electrocardiogram-gated (ECG) reconstruction for preoperative evaluation of morphological parameters, and compared with digital subtraction angiography (DSA). We also aimed to detect pulsation in unruptured intracranial aneurysms (UIAs) by using 4D-CTA, as a potential predicting factor of growth or rupture. MATERIALS: 64 patients with 64 UIAs underwent ECG-gated dynamic 4D-CTA imaging before treatment, of which 46 patients additionally underwent DSA. Original scanning data were reconstructed to produce 20 data sets of cardiac cycles with 5%-time intervals. The extent of agreement on UIAs morphological features assessed with 4D-CTA and DSA was estimated using the k coefficient of the Kappa test. The radiation doses were also calculated and compared between 4D-CTA and DSA. In the aneurysmal surgically treated in our institution, we were able to compare the surgical findings of the aneurysm wall with 4D-CTA images. We performed long-term follow-up on untreated patients. RESULTS: The morphological characteristics detected by 4D-CTA and DSA were consistent in aneurysm location (k = 1.0), shape (k = 0.76), maximum diameter (k = 0.94), aneurysm neck (k = 0.79) and proximity to parent and branch vessels (k = 0.85). 4D-CTA required lower radiation doses (0.32 ± 0.11 mSv) than DSA (0.84 ± 0.37 mSv, P < 0.001). Pulsation was detected in 26 of the 64 unruptured aneurysms, and all underwent neurosurgical clipping or interventional embolization. In aneurysms surgically treated in our hospital, we observed a significant correlation between 4D-CTA findings and surgical evaluation of the aneurysmal wall, in particular the irregular pulsations detected on 4D-CTA have demonstrated to correspond to dark-reddish thinner wall at surgery. CONCLUSIONS: In this proof-of-concept study, 4D-CTA provided real-time, non-invasive preoperative assessments of UIAs comparable to DSA. Moreover, optimal correlation between the irregular pulsation detected by 4D-CTA and the surgical findings support a possible role of this technique to identify aneurysms with a higher risk of rupture. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12880-023-01107-1.
format Online
Article
Text
id pubmed-10585900
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-105859002023-10-20 Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings Yang, Liping Gao, Xing Gao, Chao Xu, Shichuan Cao, Shaodong BMC Med Imaging Research BACKGROUND: This study was to prospectively investigate the feasibility of four-dimensional computed tomography angiography (4D-CTA) with electrocardiogram-gated (ECG) reconstruction for preoperative evaluation of morphological parameters, and compared with digital subtraction angiography (DSA). We also aimed to detect pulsation in unruptured intracranial aneurysms (UIAs) by using 4D-CTA, as a potential predicting factor of growth or rupture. MATERIALS: 64 patients with 64 UIAs underwent ECG-gated dynamic 4D-CTA imaging before treatment, of which 46 patients additionally underwent DSA. Original scanning data were reconstructed to produce 20 data sets of cardiac cycles with 5%-time intervals. The extent of agreement on UIAs morphological features assessed with 4D-CTA and DSA was estimated using the k coefficient of the Kappa test. The radiation doses were also calculated and compared between 4D-CTA and DSA. In the aneurysmal surgically treated in our institution, we were able to compare the surgical findings of the aneurysm wall with 4D-CTA images. We performed long-term follow-up on untreated patients. RESULTS: The morphological characteristics detected by 4D-CTA and DSA were consistent in aneurysm location (k = 1.0), shape (k = 0.76), maximum diameter (k = 0.94), aneurysm neck (k = 0.79) and proximity to parent and branch vessels (k = 0.85). 4D-CTA required lower radiation doses (0.32 ± 0.11 mSv) than DSA (0.84 ± 0.37 mSv, P < 0.001). Pulsation was detected in 26 of the 64 unruptured aneurysms, and all underwent neurosurgical clipping or interventional embolization. In aneurysms surgically treated in our hospital, we observed a significant correlation between 4D-CTA findings and surgical evaluation of the aneurysmal wall, in particular the irregular pulsations detected on 4D-CTA have demonstrated to correspond to dark-reddish thinner wall at surgery. CONCLUSIONS: In this proof-of-concept study, 4D-CTA provided real-time, non-invasive preoperative assessments of UIAs comparable to DSA. Moreover, optimal correlation between the irregular pulsation detected by 4D-CTA and the surgical findings support a possible role of this technique to identify aneurysms with a higher risk of rupture. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12880-023-01107-1. BioMed Central 2023-10-18 /pmc/articles/PMC10585900/ /pubmed/37853358 http://dx.doi.org/10.1186/s12880-023-01107-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Yang, Liping
Gao, Xing
Gao, Chao
Xu, Shichuan
Cao, Shaodong
Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings
title Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings
title_full Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings
title_fullStr Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings
title_full_unstemmed Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings
title_short Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings
title_sort dynamic evaluation of unruptured intracranial aneurysms by 4d-ct angiography: comparison with digital subtraction angiography (dsa) and surgical findings
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10585900/
https://www.ncbi.nlm.nih.gov/pubmed/37853358
http://dx.doi.org/10.1186/s12880-023-01107-1
work_keys_str_mv AT yangliping dynamicevaluationofunrupturedintracranialaneurysmsby4dctangiographycomparisonwithdigitalsubtractionangiographydsaandsurgicalfindings
AT gaoxing dynamicevaluationofunrupturedintracranialaneurysmsby4dctangiographycomparisonwithdigitalsubtractionangiographydsaandsurgicalfindings
AT gaochao dynamicevaluationofunrupturedintracranialaneurysmsby4dctangiographycomparisonwithdigitalsubtractionangiographydsaandsurgicalfindings
AT xushichuan dynamicevaluationofunrupturedintracranialaneurysmsby4dctangiographycomparisonwithdigitalsubtractionangiographydsaandsurgicalfindings
AT caoshaodong dynamicevaluationofunrupturedintracranialaneurysmsby4dctangiographycomparisonwithdigitalsubtractionangiographydsaandsurgicalfindings