Cargando…

Experimental Investigation of the Impact of Particle Size on Its Distribution within a Horizontal Wellbore

[Image: see text] Fracture conductivity is directly affected by an uneven proppant distribution, which affects the productivity of a well. The distributions of 40/70 mesh white sand compared to 100 mesh brown sand in a horizontal wellbore were investigated in this study. The apparatus used to conduc...

Descripción completa

Detalles Bibliográficos
Autores principales: Alajmei, Shabeeb, Budiman, Ose, Aljawad, Murtada S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10586304/
https://www.ncbi.nlm.nih.gov/pubmed/37867654
http://dx.doi.org/10.1021/acsomega.3c06257
_version_ 1785123130831798272
author Alajmei, Shabeeb
Budiman, Ose
Aljawad, Murtada S.
author_facet Alajmei, Shabeeb
Budiman, Ose
Aljawad, Murtada S.
author_sort Alajmei, Shabeeb
collection PubMed
description [Image: see text] Fracture conductivity is directly affected by an uneven proppant distribution, which affects the productivity of a well. The distributions of 40/70 mesh white sand compared to 100 mesh brown sand in a horizontal wellbore were investigated in this study. The apparatus used to conduct these tests was a 30 ft-long transparent horizontal wellbore with three perforation clusters. The proppant distribution was examined experimentally by injecting slurries at three different injection rates ranging from 20 to 75 gpm. The proppant concentration of both sands increased for each test from 0.5 to 2 ppg. The proppant concentrations and injection rates were used with multiple perforation configurations (orientations) including extreme limited entry perforations. The results confirmed that the injection rates significantly affected the proppant distributions across the different perforation clusters. Even distribution of the 40/70 mesh sand can be obtained using a 1 shot per foot (SPF) top perforation design. The 100 mesh sand was evenly distributed using a 4 SPF perforation configuration. The settling percentage was calculated for each experiment to determine the quantity of 40/70 mesh and 100 mesh sand settled at the bottom of the horizontal wellbore. A carrier fluid can suspend the sand more effectively with a higher injection rate, reducing the average sand settling to 2% in the case of the 100 mesh sand compared with approximately 8% for the 40/70 mesh sand at similar injection rates. This research confirms the need to use a 100 mesh at high injection rates to reduce sand settling during the hydraulic fracturing process.
format Online
Article
Text
id pubmed-10586304
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-105863042023-10-20 Experimental Investigation of the Impact of Particle Size on Its Distribution within a Horizontal Wellbore Alajmei, Shabeeb Budiman, Ose Aljawad, Murtada S. ACS Omega [Image: see text] Fracture conductivity is directly affected by an uneven proppant distribution, which affects the productivity of a well. The distributions of 40/70 mesh white sand compared to 100 mesh brown sand in a horizontal wellbore were investigated in this study. The apparatus used to conduct these tests was a 30 ft-long transparent horizontal wellbore with three perforation clusters. The proppant distribution was examined experimentally by injecting slurries at three different injection rates ranging from 20 to 75 gpm. The proppant concentration of both sands increased for each test from 0.5 to 2 ppg. The proppant concentrations and injection rates were used with multiple perforation configurations (orientations) including extreme limited entry perforations. The results confirmed that the injection rates significantly affected the proppant distributions across the different perforation clusters. Even distribution of the 40/70 mesh sand can be obtained using a 1 shot per foot (SPF) top perforation design. The 100 mesh sand was evenly distributed using a 4 SPF perforation configuration. The settling percentage was calculated for each experiment to determine the quantity of 40/70 mesh and 100 mesh sand settled at the bottom of the horizontal wellbore. A carrier fluid can suspend the sand more effectively with a higher injection rate, reducing the average sand settling to 2% in the case of the 100 mesh sand compared with approximately 8% for the 40/70 mesh sand at similar injection rates. This research confirms the need to use a 100 mesh at high injection rates to reduce sand settling during the hydraulic fracturing process. American Chemical Society 2023-10-04 /pmc/articles/PMC10586304/ /pubmed/37867654 http://dx.doi.org/10.1021/acsomega.3c06257 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Alajmei, Shabeeb
Budiman, Ose
Aljawad, Murtada S.
Experimental Investigation of the Impact of Particle Size on Its Distribution within a Horizontal Wellbore
title Experimental Investigation of the Impact of Particle Size on Its Distribution within a Horizontal Wellbore
title_full Experimental Investigation of the Impact of Particle Size on Its Distribution within a Horizontal Wellbore
title_fullStr Experimental Investigation of the Impact of Particle Size on Its Distribution within a Horizontal Wellbore
title_full_unstemmed Experimental Investigation of the Impact of Particle Size on Its Distribution within a Horizontal Wellbore
title_short Experimental Investigation of the Impact of Particle Size on Its Distribution within a Horizontal Wellbore
title_sort experimental investigation of the impact of particle size on its distribution within a horizontal wellbore
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10586304/
https://www.ncbi.nlm.nih.gov/pubmed/37867654
http://dx.doi.org/10.1021/acsomega.3c06257
work_keys_str_mv AT alajmeishabeeb experimentalinvestigationoftheimpactofparticlesizeonitsdistributionwithinahorizontalwellbore
AT budimanose experimentalinvestigationoftheimpactofparticlesizeonitsdistributionwithinahorizontalwellbore
AT aljawadmurtadas experimentalinvestigationoftheimpactofparticlesizeonitsdistributionwithinahorizontalwellbore