Cargando…
A side-by-side comparison of the new VITEK MS PRIME and the MALDI Biotyper sirius in the clinical microbiology laboratory
PURPOSE: This study aims to evaluate the performance of two latest generation matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems in routine laboratory settings, focusing on turnaround time (TAT), time to results (TTR), hands-on time, and identificatio...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587274/ https://www.ncbi.nlm.nih.gov/pubmed/37794128 http://dx.doi.org/10.1007/s10096-023-04666-x |
_version_ | 1785123326502371328 |
---|---|
author | Thelen, Philipp Graeber, Sandra Schmidt, Erika Hamprecht, Axel |
author_facet | Thelen, Philipp Graeber, Sandra Schmidt, Erika Hamprecht, Axel |
author_sort | Thelen, Philipp |
collection | PubMed |
description | PURPOSE: This study aims to evaluate the performance of two latest generation matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems in routine laboratory settings, focusing on turnaround time (TAT), time to results (TTR), hands-on time, and identification rate. METHODS: We conducted a time and motion study on three workflow scenarios to simulate different laboratory settings. Overall, 618 bacterial isolates from a tertiary hospital’s laboratory were processed using the VITEK MS PRIME (bioMérieux) and the MALDI Biotyper sirius (Bruker Daltonics) and their corresponding databases VITEK IVD Database 3.2 and MBT reference library 12. RESULTS: The target preparation process showed no significant difference in TAT, but the Biotyper workflow had a shorter hands-on time by 3 to 6 min. In the measurement process, TTR was three to five times shorter for the Biotyper sirius while hands-on time was significantly shorter for VITEK MS PRIME (approximately 1.5 min per target). The identification rate without retesting was 97.9% for VITEK MS PRIME and 98.9% for Biotyper sirius. Both systems achieved 100% agreement at genus and 96.2% at species level. CONCLUSION: Both systems exhibited excellent identification rates for routine bacterial isolates. Due to its high speed, the Biotyper sirius is suited for laboratories with high sample throughput and a workflow designed for processing larger batches. The VITEK MS PRIME, with its “load and go” system accommodating up to 16 targets, reduces hands-on time, making it a reasonable choice for laboratories with fewer identifications overall but a higher number of targets and a workflow designed for parallel processing on different workstations. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10096-023-04666-x. |
format | Online Article Text |
id | pubmed-10587274 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-105872742023-10-21 A side-by-side comparison of the new VITEK MS PRIME and the MALDI Biotyper sirius in the clinical microbiology laboratory Thelen, Philipp Graeber, Sandra Schmidt, Erika Hamprecht, Axel Eur J Clin Microbiol Infect Dis Original Article PURPOSE: This study aims to evaluate the performance of two latest generation matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems in routine laboratory settings, focusing on turnaround time (TAT), time to results (TTR), hands-on time, and identification rate. METHODS: We conducted a time and motion study on three workflow scenarios to simulate different laboratory settings. Overall, 618 bacterial isolates from a tertiary hospital’s laboratory were processed using the VITEK MS PRIME (bioMérieux) and the MALDI Biotyper sirius (Bruker Daltonics) and their corresponding databases VITEK IVD Database 3.2 and MBT reference library 12. RESULTS: The target preparation process showed no significant difference in TAT, but the Biotyper workflow had a shorter hands-on time by 3 to 6 min. In the measurement process, TTR was three to five times shorter for the Biotyper sirius while hands-on time was significantly shorter for VITEK MS PRIME (approximately 1.5 min per target). The identification rate without retesting was 97.9% for VITEK MS PRIME and 98.9% for Biotyper sirius. Both systems achieved 100% agreement at genus and 96.2% at species level. CONCLUSION: Both systems exhibited excellent identification rates for routine bacterial isolates. Due to its high speed, the Biotyper sirius is suited for laboratories with high sample throughput and a workflow designed for processing larger batches. The VITEK MS PRIME, with its “load and go” system accommodating up to 16 targets, reduces hands-on time, making it a reasonable choice for laboratories with fewer identifications overall but a higher number of targets and a workflow designed for parallel processing on different workstations. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10096-023-04666-x. Springer Berlin Heidelberg 2023-10-05 2023 /pmc/articles/PMC10587274/ /pubmed/37794128 http://dx.doi.org/10.1007/s10096-023-04666-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Thelen, Philipp Graeber, Sandra Schmidt, Erika Hamprecht, Axel A side-by-side comparison of the new VITEK MS PRIME and the MALDI Biotyper sirius in the clinical microbiology laboratory |
title | A side-by-side comparison of the new VITEK MS PRIME and the MALDI Biotyper sirius in the clinical microbiology laboratory |
title_full | A side-by-side comparison of the new VITEK MS PRIME and the MALDI Biotyper sirius in the clinical microbiology laboratory |
title_fullStr | A side-by-side comparison of the new VITEK MS PRIME and the MALDI Biotyper sirius in the clinical microbiology laboratory |
title_full_unstemmed | A side-by-side comparison of the new VITEK MS PRIME and the MALDI Biotyper sirius in the clinical microbiology laboratory |
title_short | A side-by-side comparison of the new VITEK MS PRIME and the MALDI Biotyper sirius in the clinical microbiology laboratory |
title_sort | side-by-side comparison of the new vitek ms prime and the maldi biotyper sirius in the clinical microbiology laboratory |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587274/ https://www.ncbi.nlm.nih.gov/pubmed/37794128 http://dx.doi.org/10.1007/s10096-023-04666-x |
work_keys_str_mv | AT thelenphilipp asidebysidecomparisonofthenewvitekmsprimeandthemaldibiotypersiriusintheclinicalmicrobiologylaboratory AT graebersandra asidebysidecomparisonofthenewvitekmsprimeandthemaldibiotypersiriusintheclinicalmicrobiologylaboratory AT schmidterika asidebysidecomparisonofthenewvitekmsprimeandthemaldibiotypersiriusintheclinicalmicrobiologylaboratory AT hamprechtaxel asidebysidecomparisonofthenewvitekmsprimeandthemaldibiotypersiriusintheclinicalmicrobiologylaboratory AT thelenphilipp sidebysidecomparisonofthenewvitekmsprimeandthemaldibiotypersiriusintheclinicalmicrobiologylaboratory AT graebersandra sidebysidecomparisonofthenewvitekmsprimeandthemaldibiotypersiriusintheclinicalmicrobiologylaboratory AT schmidterika sidebysidecomparisonofthenewvitekmsprimeandthemaldibiotypersiriusintheclinicalmicrobiologylaboratory AT hamprechtaxel sidebysidecomparisonofthenewvitekmsprimeandthemaldibiotypersiriusintheclinicalmicrobiologylaboratory |