The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug
This study aimed to investigate the effects of topical anesthetic and fluorescein drops on intraocular pressure (IOP), central corneal thickness (CCT) and biomechanical properties as measured by Corvis ST (CST-Oculus; Wezlar, Germany) in healthy eyes. A cross-sectional observational study was conduc...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587345/ https://www.ncbi.nlm.nih.gov/pubmed/37857798 http://dx.doi.org/10.1038/s41598-023-45165-5 |
_version_ | 1785123343372910592 |
---|---|
author | Macedo, Marcelo Hatanaka, Marcelo Barboza, Wilma Lelis Mingione, Gabriella Marranghello Ambrósio, Renato Susanna, Remo |
author_facet | Macedo, Marcelo Hatanaka, Marcelo Barboza, Wilma Lelis Mingione, Gabriella Marranghello Ambrósio, Renato Susanna, Remo |
author_sort | Macedo, Marcelo |
collection | PubMed |
description | This study aimed to investigate the effects of topical anesthetic and fluorescein drops on intraocular pressure (IOP), central corneal thickness (CCT) and biomechanical properties as measured by Corvis ST (CST-Oculus; Wezlar, Germany) in healthy eyes. A cross-sectional observational study was conducted on 46 healthy patients. The CST measurements were obtained before and immediately after the instillation of topical anesthetic and fluorescein drops. Pre-post instillation data were statistically analyzed. IOP measurements were compared to Goldmann's Applanation Tonometry (GAT), which was also performed after drops instillation. Biomechanical parameters analyzed included applanation 1 velocity, applanation 2 velocity, applanation 1 time, applanation 2 time, whole eye movement, deflection amplitude, and stiffness parameter at first applanation. A statistically significant difference in IOP, both for non-corrected IOP (IOPnct) and biomechanically corrected IOP (bIOP), was observed before and after the instillation of eyedrops. Despite this statistical significance, the observed difference lacked clinical relevance. The IOPnct demonstrated a significant difference pre and post-anesthetic and fluorescein instillation compared to GAT (14.99 ± 2.27 mmHg pre-instillation and 14.62 ± 2.50 mmHg post-instillation, versus 13.98 ± 2.04 mmHg, with p-values of 0.0014 and 0.0490, respectively). Comparable findings were noted when justaposing bIOP to GAT (14.53 ± 2.10 mmHg pre-instillation and 13.15 ± 2.25 mmHg post-instillation, against 13.98 ± 2.04 mmHg, with p-values of 0.0391 and 0.0022, respectively). Additionally, CCT measurements revealed a statistically significant elevation following the administration of topical anesthetic and fluorescein drops (from 544.64 ± 39.85 µm to 586.74 ± 41.71 µm, p < 0.01. None of the analyzed biomechanical parameters showed statistically significant differences after drops instillation. While the administration of topical anesthetic and fluorescein drops induced a statistically significant alteration in both IOPnct and bIOP readings, these changes were not clinically consequential. Furthermore, a notable statistical rise was observed in CCT measurements post-drops instillation, as determined by CST. Yet, corneal biomechanical parameters remained unaffected. |
format | Online Article Text |
id | pubmed-10587345 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-105873452023-10-21 The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug Macedo, Marcelo Hatanaka, Marcelo Barboza, Wilma Lelis Mingione, Gabriella Marranghello Ambrósio, Renato Susanna, Remo Sci Rep Article This study aimed to investigate the effects of topical anesthetic and fluorescein drops on intraocular pressure (IOP), central corneal thickness (CCT) and biomechanical properties as measured by Corvis ST (CST-Oculus; Wezlar, Germany) in healthy eyes. A cross-sectional observational study was conducted on 46 healthy patients. The CST measurements were obtained before and immediately after the instillation of topical anesthetic and fluorescein drops. Pre-post instillation data were statistically analyzed. IOP measurements were compared to Goldmann's Applanation Tonometry (GAT), which was also performed after drops instillation. Biomechanical parameters analyzed included applanation 1 velocity, applanation 2 velocity, applanation 1 time, applanation 2 time, whole eye movement, deflection amplitude, and stiffness parameter at first applanation. A statistically significant difference in IOP, both for non-corrected IOP (IOPnct) and biomechanically corrected IOP (bIOP), was observed before and after the instillation of eyedrops. Despite this statistical significance, the observed difference lacked clinical relevance. The IOPnct demonstrated a significant difference pre and post-anesthetic and fluorescein instillation compared to GAT (14.99 ± 2.27 mmHg pre-instillation and 14.62 ± 2.50 mmHg post-instillation, versus 13.98 ± 2.04 mmHg, with p-values of 0.0014 and 0.0490, respectively). Comparable findings were noted when justaposing bIOP to GAT (14.53 ± 2.10 mmHg pre-instillation and 13.15 ± 2.25 mmHg post-instillation, against 13.98 ± 2.04 mmHg, with p-values of 0.0391 and 0.0022, respectively). Additionally, CCT measurements revealed a statistically significant elevation following the administration of topical anesthetic and fluorescein drops (from 544.64 ± 39.85 µm to 586.74 ± 41.71 µm, p < 0.01. None of the analyzed biomechanical parameters showed statistically significant differences after drops instillation. While the administration of topical anesthetic and fluorescein drops induced a statistically significant alteration in both IOPnct and bIOP readings, these changes were not clinically consequential. Furthermore, a notable statistical rise was observed in CCT measurements post-drops instillation, as determined by CST. Yet, corneal biomechanical parameters remained unaffected. Nature Publishing Group UK 2023-10-19 /pmc/articles/PMC10587345/ /pubmed/37857798 http://dx.doi.org/10.1038/s41598-023-45165-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Macedo, Marcelo Hatanaka, Marcelo Barboza, Wilma Lelis Mingione, Gabriella Marranghello Ambrósio, Renato Susanna, Remo The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug |
title | The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug |
title_full | The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug |
title_fullStr | The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug |
title_full_unstemmed | The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug |
title_short | The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug |
title_sort | influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic scheimpflug |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587345/ https://www.ncbi.nlm.nih.gov/pubmed/37857798 http://dx.doi.org/10.1038/s41598-023-45165-5 |
work_keys_str_mv | AT macedomarcelo theinfluenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT hatanakamarcelo theinfluenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT barbozawilmalelis theinfluenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT mingionegabriellamarranghello theinfluenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT ambrosiorenato theinfluenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT susannaremo theinfluenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT macedomarcelo influenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT hatanakamarcelo influenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT barbozawilmalelis influenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT mingionegabriellamarranghello influenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT ambrosiorenato influenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug AT susannaremo influenceoftopicalanestheticandfluoresceinonnoncontacttonometrymeasurementsusingultrahighspeeddynamicscheimpflug |