Cargando…

Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience

Purpose: Structural valve deterioration (SVD) remains a limitation on the use of bioprosthetic valves, with patient and valve-related factors contributing to early SVD. The Trifecta valve has been reported to have excellent hemodynamics but studies have highlighted early failure. We present a review...

Descripción completa

Detalles Bibliográficos
Autores principales: Tnay, Trevor D., Kang, Lily, Mekhail, Andrew, Galvin, Sean D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587479/
https://www.ncbi.nlm.nih.gov/pubmed/36935120
http://dx.doi.org/10.5761/atcs.oa.23-00007
_version_ 1785123372863062016
author Tnay, Trevor D.
Kang, Lily
Mekhail, Andrew
Galvin, Sean D.
author_facet Tnay, Trevor D.
Kang, Lily
Mekhail, Andrew
Galvin, Sean D.
author_sort Tnay, Trevor D.
collection PubMed
description Purpose: Structural valve deterioration (SVD) remains a limitation on the use of bioprosthetic valves, with patient and valve-related factors contributing to early SVD. The Trifecta valve has been reported to have excellent hemodynamics but studies have highlighted early failure. We present a review and case series at a New Zealand tertiary hospital defining early SVD as failure within 3 years of implant. Methods: A retrospective review from January 2015 to July 2019 included 525 patients undergoing surgical aortic valve replacement with 263 patients receiving an Abbott Trifecta or Trifecta Glide Technology (GT) valve. Our review found an acceptable safety profile for the valve with excellent hemodynamics, with a low mortality, stroke, and permanent pacemaker rate. Results: Three patients out of 263 were identified from the study period as having early SVD requiring reintervention within 3 years of valve implantation leading to a 1.14% failure rate. One of the valves that had early SVD was a new generation Trifecta GT. An additional four patients were identified to have valves implanted prior to the study period and had valve failure at greater than 3 years post implantation. Five cases had cusp tears as their mechanism of failure, raising concerns about durability. Conclusion: The Trifecta valve has an acceptable safety profile and offers good hemodynamics due to the externally mounted leaflets. However, our experience of early SVD and failure is concerning for valve durability. Further comparison to other bioprosthetic valves and longer term follow-up are required to characterize the mechanism of failures.
format Online
Article
Text
id pubmed-10587479
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery
record_format MEDLINE/PubMed
spelling pubmed-105874792023-10-21 Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience Tnay, Trevor D. Kang, Lily Mekhail, Andrew Galvin, Sean D. Ann Thorac Cardiovasc Surg Original Article Purpose: Structural valve deterioration (SVD) remains a limitation on the use of bioprosthetic valves, with patient and valve-related factors contributing to early SVD. The Trifecta valve has been reported to have excellent hemodynamics but studies have highlighted early failure. We present a review and case series at a New Zealand tertiary hospital defining early SVD as failure within 3 years of implant. Methods: A retrospective review from January 2015 to July 2019 included 525 patients undergoing surgical aortic valve replacement with 263 patients receiving an Abbott Trifecta or Trifecta Glide Technology (GT) valve. Our review found an acceptable safety profile for the valve with excellent hemodynamics, with a low mortality, stroke, and permanent pacemaker rate. Results: Three patients out of 263 were identified from the study period as having early SVD requiring reintervention within 3 years of valve implantation leading to a 1.14% failure rate. One of the valves that had early SVD was a new generation Trifecta GT. An additional four patients were identified to have valves implanted prior to the study period and had valve failure at greater than 3 years post implantation. Five cases had cusp tears as their mechanism of failure, raising concerns about durability. Conclusion: The Trifecta valve has an acceptable safety profile and offers good hemodynamics due to the externally mounted leaflets. However, our experience of early SVD and failure is concerning for valve durability. Further comparison to other bioprosthetic valves and longer term follow-up are required to characterize the mechanism of failures. The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery 2023-03-18 2023 /pmc/articles/PMC10587479/ /pubmed/36935120 http://dx.doi.org/10.5761/atcs.oa.23-00007 Text en ©2023 Annals of Thoracic and Cardiovascular Surgery https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Original Article
Tnay, Trevor D.
Kang, Lily
Mekhail, Andrew
Galvin, Sean D.
Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience
title Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience
title_full Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience
title_fullStr Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience
title_full_unstemmed Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience
title_short Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience
title_sort case series of early structural valve deterioration of trifecta bioprosthesis – new zealand experience
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587479/
https://www.ncbi.nlm.nih.gov/pubmed/36935120
http://dx.doi.org/10.5761/atcs.oa.23-00007
work_keys_str_mv AT tnaytrevord caseseriesofearlystructuralvalvedeteriorationoftrifectabioprosthesisnewzealandexperience
AT kanglily caseseriesofearlystructuralvalvedeteriorationoftrifectabioprosthesisnewzealandexperience
AT mekhailandrew caseseriesofearlystructuralvalvedeteriorationoftrifectabioprosthesisnewzealandexperience
AT galvinseand caseseriesofearlystructuralvalvedeteriorationoftrifectabioprosthesisnewzealandexperience