Cargando…
Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience
Purpose: Structural valve deterioration (SVD) remains a limitation on the use of bioprosthetic valves, with patient and valve-related factors contributing to early SVD. The Trifecta valve has been reported to have excellent hemodynamics but studies have highlighted early failure. We present a review...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587479/ https://www.ncbi.nlm.nih.gov/pubmed/36935120 http://dx.doi.org/10.5761/atcs.oa.23-00007 |
_version_ | 1785123372863062016 |
---|---|
author | Tnay, Trevor D. Kang, Lily Mekhail, Andrew Galvin, Sean D. |
author_facet | Tnay, Trevor D. Kang, Lily Mekhail, Andrew Galvin, Sean D. |
author_sort | Tnay, Trevor D. |
collection | PubMed |
description | Purpose: Structural valve deterioration (SVD) remains a limitation on the use of bioprosthetic valves, with patient and valve-related factors contributing to early SVD. The Trifecta valve has been reported to have excellent hemodynamics but studies have highlighted early failure. We present a review and case series at a New Zealand tertiary hospital defining early SVD as failure within 3 years of implant. Methods: A retrospective review from January 2015 to July 2019 included 525 patients undergoing surgical aortic valve replacement with 263 patients receiving an Abbott Trifecta or Trifecta Glide Technology (GT) valve. Our review found an acceptable safety profile for the valve with excellent hemodynamics, with a low mortality, stroke, and permanent pacemaker rate. Results: Three patients out of 263 were identified from the study period as having early SVD requiring reintervention within 3 years of valve implantation leading to a 1.14% failure rate. One of the valves that had early SVD was a new generation Trifecta GT. An additional four patients were identified to have valves implanted prior to the study period and had valve failure at greater than 3 years post implantation. Five cases had cusp tears as their mechanism of failure, raising concerns about durability. Conclusion: The Trifecta valve has an acceptable safety profile and offers good hemodynamics due to the externally mounted leaflets. However, our experience of early SVD and failure is concerning for valve durability. Further comparison to other bioprosthetic valves and longer term follow-up are required to characterize the mechanism of failures. |
format | Online Article Text |
id | pubmed-10587479 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-105874792023-10-21 Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience Tnay, Trevor D. Kang, Lily Mekhail, Andrew Galvin, Sean D. Ann Thorac Cardiovasc Surg Original Article Purpose: Structural valve deterioration (SVD) remains a limitation on the use of bioprosthetic valves, with patient and valve-related factors contributing to early SVD. The Trifecta valve has been reported to have excellent hemodynamics but studies have highlighted early failure. We present a review and case series at a New Zealand tertiary hospital defining early SVD as failure within 3 years of implant. Methods: A retrospective review from January 2015 to July 2019 included 525 patients undergoing surgical aortic valve replacement with 263 patients receiving an Abbott Trifecta or Trifecta Glide Technology (GT) valve. Our review found an acceptable safety profile for the valve with excellent hemodynamics, with a low mortality, stroke, and permanent pacemaker rate. Results: Three patients out of 263 were identified from the study period as having early SVD requiring reintervention within 3 years of valve implantation leading to a 1.14% failure rate. One of the valves that had early SVD was a new generation Trifecta GT. An additional four patients were identified to have valves implanted prior to the study period and had valve failure at greater than 3 years post implantation. Five cases had cusp tears as their mechanism of failure, raising concerns about durability. Conclusion: The Trifecta valve has an acceptable safety profile and offers good hemodynamics due to the externally mounted leaflets. However, our experience of early SVD and failure is concerning for valve durability. Further comparison to other bioprosthetic valves and longer term follow-up are required to characterize the mechanism of failures. The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery 2023-03-18 2023 /pmc/articles/PMC10587479/ /pubmed/36935120 http://dx.doi.org/10.5761/atcs.oa.23-00007 Text en ©2023 Annals of Thoracic and Cardiovascular Surgery https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Article Tnay, Trevor D. Kang, Lily Mekhail, Andrew Galvin, Sean D. Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience |
title | Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience |
title_full | Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience |
title_fullStr | Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience |
title_full_unstemmed | Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience |
title_short | Case Series of Early Structural Valve Deterioration of Trifecta Bioprosthesis – New Zealand Experience |
title_sort | case series of early structural valve deterioration of trifecta bioprosthesis – new zealand experience |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10587479/ https://www.ncbi.nlm.nih.gov/pubmed/36935120 http://dx.doi.org/10.5761/atcs.oa.23-00007 |
work_keys_str_mv | AT tnaytrevord caseseriesofearlystructuralvalvedeteriorationoftrifectabioprosthesisnewzealandexperience AT kanglily caseseriesofearlystructuralvalvedeteriorationoftrifectabioprosthesisnewzealandexperience AT mekhailandrew caseseriesofearlystructuralvalvedeteriorationoftrifectabioprosthesisnewzealandexperience AT galvinseand caseseriesofearlystructuralvalvedeteriorationoftrifectabioprosthesisnewzealandexperience |