Cargando…
Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications
Cardiac magnetic resonance (CMR) four-dimensional (4D) flow is a novel method for flow quantification potentially helpful in management of mitral valve regurgitation (MVR). In this systematic review, we aimed to depict the clinical role of intraventricular 4D-flow in MVR. The reproducibility, techni...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10589148/ https://www.ncbi.nlm.nih.gov/pubmed/37322317 http://dx.doi.org/10.1007/s10554-023-02893-z |
_version_ | 1785123725686865920 |
---|---|
author | Safarkhanlo, Yasaman Jung, Bernd Bernhard, Benedikt Peper, Eva S. Kwong, Raymond Y. Bastiaansen, Jessica A. M. Gräni, Christoph |
author_facet | Safarkhanlo, Yasaman Jung, Bernd Bernhard, Benedikt Peper, Eva S. Kwong, Raymond Y. Bastiaansen, Jessica A. M. Gräni, Christoph |
author_sort | Safarkhanlo, Yasaman |
collection | PubMed |
description | Cardiac magnetic resonance (CMR) four-dimensional (4D) flow is a novel method for flow quantification potentially helpful in management of mitral valve regurgitation (MVR). In this systematic review, we aimed to depict the clinical role of intraventricular 4D-flow in MVR. The reproducibility, technical aspects, and comparison against conventional techniques were evaluated. Published studies on SCOPUS, MEDLINE, and EMBASE were included using search terms on 4D-flow CMR in MVR. Out of 420 screened articles, 18 studies fulfilled our inclusion criteria. All studies (n = 18, 100%) assessed MVR using 4D-flow intraventricular annular inflow (4D-flow(AIM)) method, which calculates the regurgitation by subtracting the aortic forward flow from the mitral forward flow. Thereof, 4D-flow jet quantification (4D-flow(jet)) was assessed in 5 (28%), standard 2D phase-contrast (2D-PC) flow imaging in 8 (44%) and the volumetric method (the deviation of left ventricle stroke volume and right ventricular stroke volume) in 2 (11%) studies. Inter-method correlations among the 4 MVR quantification methods were heterogeneous across studies, ranging from moderate to excellent correlations. Two studies compared 4D-flow(AIM) to echocardiography with moderate correlation. In 12 (63%) studies the reproducibility of 4D-flow techniques in quantifying MVR was studied. Thereof, 9 (75%) studies investigated the reproducibility of the 4D-flow(AIM) method and the majority (n = 7, 78%) reported good to excellent intra- and inter-reader reproducibility. Intraventricular 4D-flow(AIM) provides high reproducibility with heterogeneous correlations to conventional quantification methods. Due to the absence of a gold standard and unknown accuracies, future longitudinal outcome studies are needed to assess the clinical value of 4D-flow in the clinical setting of MVR. |
format | Online Article Text |
id | pubmed-10589148 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-105891482023-10-22 Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications Safarkhanlo, Yasaman Jung, Bernd Bernhard, Benedikt Peper, Eva S. Kwong, Raymond Y. Bastiaansen, Jessica A. M. Gräni, Christoph Int J Cardiovasc Imaging Review Article Cardiac magnetic resonance (CMR) four-dimensional (4D) flow is a novel method for flow quantification potentially helpful in management of mitral valve regurgitation (MVR). In this systematic review, we aimed to depict the clinical role of intraventricular 4D-flow in MVR. The reproducibility, technical aspects, and comparison against conventional techniques were evaluated. Published studies on SCOPUS, MEDLINE, and EMBASE were included using search terms on 4D-flow CMR in MVR. Out of 420 screened articles, 18 studies fulfilled our inclusion criteria. All studies (n = 18, 100%) assessed MVR using 4D-flow intraventricular annular inflow (4D-flow(AIM)) method, which calculates the regurgitation by subtracting the aortic forward flow from the mitral forward flow. Thereof, 4D-flow jet quantification (4D-flow(jet)) was assessed in 5 (28%), standard 2D phase-contrast (2D-PC) flow imaging in 8 (44%) and the volumetric method (the deviation of left ventricle stroke volume and right ventricular stroke volume) in 2 (11%) studies. Inter-method correlations among the 4 MVR quantification methods were heterogeneous across studies, ranging from moderate to excellent correlations. Two studies compared 4D-flow(AIM) to echocardiography with moderate correlation. In 12 (63%) studies the reproducibility of 4D-flow techniques in quantifying MVR was studied. Thereof, 9 (75%) studies investigated the reproducibility of the 4D-flow(AIM) method and the majority (n = 7, 78%) reported good to excellent intra- and inter-reader reproducibility. Intraventricular 4D-flow(AIM) provides high reproducibility with heterogeneous correlations to conventional quantification methods. Due to the absence of a gold standard and unknown accuracies, future longitudinal outcome studies are needed to assess the clinical value of 4D-flow in the clinical setting of MVR. Springer Netherlands 2023-06-16 2023 /pmc/articles/PMC10589148/ /pubmed/37322317 http://dx.doi.org/10.1007/s10554-023-02893-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Review Article Safarkhanlo, Yasaman Jung, Bernd Bernhard, Benedikt Peper, Eva S. Kwong, Raymond Y. Bastiaansen, Jessica A. M. Gräni, Christoph Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications |
title | Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications |
title_full | Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications |
title_fullStr | Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications |
title_full_unstemmed | Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications |
title_short | Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications |
title_sort | mitral valve regurgitation assessed by intraventricular cmr 4d-flow: a systematic review on the technological aspects and potential clinical applications |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10589148/ https://www.ncbi.nlm.nih.gov/pubmed/37322317 http://dx.doi.org/10.1007/s10554-023-02893-z |
work_keys_str_mv | AT safarkhanloyasaman mitralvalveregurgitationassessedbyintraventricularcmr4dflowasystematicreviewonthetechnologicalaspectsandpotentialclinicalapplications AT jungbernd mitralvalveregurgitationassessedbyintraventricularcmr4dflowasystematicreviewonthetechnologicalaspectsandpotentialclinicalapplications AT bernhardbenedikt mitralvalveregurgitationassessedbyintraventricularcmr4dflowasystematicreviewonthetechnologicalaspectsandpotentialclinicalapplications AT peperevas mitralvalveregurgitationassessedbyintraventricularcmr4dflowasystematicreviewonthetechnologicalaspectsandpotentialclinicalapplications AT kwongraymondy mitralvalveregurgitationassessedbyintraventricularcmr4dflowasystematicreviewonthetechnologicalaspectsandpotentialclinicalapplications AT bastiaansenjessicaam mitralvalveregurgitationassessedbyintraventricularcmr4dflowasystematicreviewonthetechnologicalaspectsandpotentialclinicalapplications AT granichristoph mitralvalveregurgitationassessedbyintraventricularcmr4dflowasystematicreviewonthetechnologicalaspectsandpotentialclinicalapplications |