Cargando…

A novel robot-assisted knee arthroplasty system (ROSA) and 1-year outcome: A single center experience

BACKGROUND: Total knee arthroplasty is a successful procedure in the treatment of knee osteoarthritis. Searches in surgical technique have focused surgeons in particular on implant alignment. For this purpose, the use of robot-assisted total knee arthroplasty has become increasingly common in the la...

Descripción completa

Detalles Bibliográficos
Autores principales: Demirtas, Yunus, Emet, Abdulsamet, Ayik, Gokhan, Cakmak, Gokhan, Aksahin, Ertugrul, Celebi, Levent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10589563/
https://www.ncbi.nlm.nih.gov/pubmed/37861507
http://dx.doi.org/10.1097/MD.0000000000035710
_version_ 1785123818728062976
author Demirtas, Yunus
Emet, Abdulsamet
Ayik, Gokhan
Cakmak, Gokhan
Aksahin, Ertugrul
Celebi, Levent
author_facet Demirtas, Yunus
Emet, Abdulsamet
Ayik, Gokhan
Cakmak, Gokhan
Aksahin, Ertugrul
Celebi, Levent
author_sort Demirtas, Yunus
collection PubMed
description BACKGROUND: Total knee arthroplasty is a successful procedure in the treatment of knee osteoarthritis. Searches in surgical technique have focused surgeons in particular on implant alignment. For this purpose, the use of robot-assisted total knee arthroplasty has become increasingly common in the last 10 years. METHODS: A total of 46 patients (66 knees) who were operated for knee osteoarthritis with Robotic Surgical Assistant (ROSA, Zimmer-Biomet, Warshaw, Indiana, USA) between 2021 and 2023 were included in the study. Preoperative planning and intraoperative incision time, total surgical time, range of motion and follow-up time recorded. Oxford knee scores and knee society scores (KSS) of the patients were compared before and after surgery. At the last follow-up Forgotten Joint Score and the sagittal and coronal plane alignments were evaluated. RESULTS: Preoperative mean Oxford score of the right knee of the patients was 18.5 ± 3.2, post-surgery mean Oxford score progressed to 43.5 ± 2.2. While the preoperative left knee Oxford score of the patients was 16.9 ± 2.3, the mean left knee Oxford score improved to 43.4 ± 2.2 postoperatively. The mean KSS score of the patients’ right knee preoperatively was 49.7 ± 3.5, and progressed to 89.2 ± 4.7 postoperatively. While the preoperative mean left knee KSS score of the patients was 46.5 ± 4.3, the mean KSS score improved to 89.8 ± 3.2 postoperatively. The mean Forgotten Joint Score of the left knee at the last follow-up of the patients was 77.4 ± 3.8, while the mean Forgotten Joint Score of the right knee was 75.4 ± 5.9. CONCLUSION: The results of ROSA-supported knee arthroplasty found to be functionally successful.
format Online
Article
Text
id pubmed-10589563
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-105895632023-10-22 A novel robot-assisted knee arthroplasty system (ROSA) and 1-year outcome: A single center experience Demirtas, Yunus Emet, Abdulsamet Ayik, Gokhan Cakmak, Gokhan Aksahin, Ertugrul Celebi, Levent Medicine (Baltimore) 7100 BACKGROUND: Total knee arthroplasty is a successful procedure in the treatment of knee osteoarthritis. Searches in surgical technique have focused surgeons in particular on implant alignment. For this purpose, the use of robot-assisted total knee arthroplasty has become increasingly common in the last 10 years. METHODS: A total of 46 patients (66 knees) who were operated for knee osteoarthritis with Robotic Surgical Assistant (ROSA, Zimmer-Biomet, Warshaw, Indiana, USA) between 2021 and 2023 were included in the study. Preoperative planning and intraoperative incision time, total surgical time, range of motion and follow-up time recorded. Oxford knee scores and knee society scores (KSS) of the patients were compared before and after surgery. At the last follow-up Forgotten Joint Score and the sagittal and coronal plane alignments were evaluated. RESULTS: Preoperative mean Oxford score of the right knee of the patients was 18.5 ± 3.2, post-surgery mean Oxford score progressed to 43.5 ± 2.2. While the preoperative left knee Oxford score of the patients was 16.9 ± 2.3, the mean left knee Oxford score improved to 43.4 ± 2.2 postoperatively. The mean KSS score of the patients’ right knee preoperatively was 49.7 ± 3.5, and progressed to 89.2 ± 4.7 postoperatively. While the preoperative mean left knee KSS score of the patients was 46.5 ± 4.3, the mean KSS score improved to 89.8 ± 3.2 postoperatively. The mean Forgotten Joint Score of the left knee at the last follow-up of the patients was 77.4 ± 3.8, while the mean Forgotten Joint Score of the right knee was 75.4 ± 5.9. CONCLUSION: The results of ROSA-supported knee arthroplasty found to be functionally successful. Lippincott Williams & Wilkins 2023-10-20 /pmc/articles/PMC10589563/ /pubmed/37861507 http://dx.doi.org/10.1097/MD.0000000000035710 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle 7100
Demirtas, Yunus
Emet, Abdulsamet
Ayik, Gokhan
Cakmak, Gokhan
Aksahin, Ertugrul
Celebi, Levent
A novel robot-assisted knee arthroplasty system (ROSA) and 1-year outcome: A single center experience
title A novel robot-assisted knee arthroplasty system (ROSA) and 1-year outcome: A single center experience
title_full A novel robot-assisted knee arthroplasty system (ROSA) and 1-year outcome: A single center experience
title_fullStr A novel robot-assisted knee arthroplasty system (ROSA) and 1-year outcome: A single center experience
title_full_unstemmed A novel robot-assisted knee arthroplasty system (ROSA) and 1-year outcome: A single center experience
title_short A novel robot-assisted knee arthroplasty system (ROSA) and 1-year outcome: A single center experience
title_sort novel robot-assisted knee arthroplasty system (rosa) and 1-year outcome: a single center experience
topic 7100
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10589563/
https://www.ncbi.nlm.nih.gov/pubmed/37861507
http://dx.doi.org/10.1097/MD.0000000000035710
work_keys_str_mv AT demirtasyunus anovelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT emetabdulsamet anovelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT ayikgokhan anovelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT cakmakgokhan anovelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT aksahinertugrul anovelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT celebilevent anovelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT demirtasyunus novelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT emetabdulsamet novelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT ayikgokhan novelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT cakmakgokhan novelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT aksahinertugrul novelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience
AT celebilevent novelrobotassistedkneearthroplastysystemrosaand1yearoutcomeasinglecenterexperience