Cargando…

Dosimetric verification of annual quality assurance for a linear accelerator using a transmission type detector

The purpose of our study is to establish an efficient quality assurance (QA) procedure using a transmission-type detector (IBA, Stealth chamber), a reference signal detector, as a field chamber. Relative dosimetry items, including monitor unit linearity, output constancy based on dose rate and field...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Dong Hyeok, Kim, Jin Sung, Lee, Rena, Ahn, So Hyun, Ahn, Woo Sang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10590446/
https://www.ncbi.nlm.nih.gov/pubmed/37865666
http://dx.doi.org/10.1038/s41598-023-45114-2
_version_ 1785123991056285696
author Choi, Dong Hyeok
Kim, Jin Sung
Lee, Rena
Ahn, So Hyun
Ahn, Woo Sang
author_facet Choi, Dong Hyeok
Kim, Jin Sung
Lee, Rena
Ahn, So Hyun
Ahn, Woo Sang
author_sort Choi, Dong Hyeok
collection PubMed
description The purpose of our study is to establish an efficient quality assurance (QA) procedure using a transmission-type detector (IBA, Stealth chamber), a reference signal detector, as a field chamber. Relative dosimetry items, including monitor unit linearity, output constancy based on dose rate and field size, and output factor were measured and compared with results obtained from the Farmer-type chamber (IBA, Wellhofer, FC65-G). Moreover, output for each field size was measured to assess its applicability to small fields. Results using the Stealth chamber were in good agreement with the FC65-G within 1.0%, except for output constancy according to gantry angle, which had a 1.1% error rate for the Stealth chamber and 2.7% for the FC65-G. Differences of up to − 6.26% output factor were observed for the Stealth chamber and up to − 0.56% for the CC-13 ionization chamber (IBA) in the 3 × 3 cm(2) field. Our study confirmed the possibility of using Stealth chambers for relative dosimetry measurement in QA.
format Online
Article
Text
id pubmed-10590446
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-105904462023-10-23 Dosimetric verification of annual quality assurance for a linear accelerator using a transmission type detector Choi, Dong Hyeok Kim, Jin Sung Lee, Rena Ahn, So Hyun Ahn, Woo Sang Sci Rep Article The purpose of our study is to establish an efficient quality assurance (QA) procedure using a transmission-type detector (IBA, Stealth chamber), a reference signal detector, as a field chamber. Relative dosimetry items, including monitor unit linearity, output constancy based on dose rate and field size, and output factor were measured and compared with results obtained from the Farmer-type chamber (IBA, Wellhofer, FC65-G). Moreover, output for each field size was measured to assess its applicability to small fields. Results using the Stealth chamber were in good agreement with the FC65-G within 1.0%, except for output constancy according to gantry angle, which had a 1.1% error rate for the Stealth chamber and 2.7% for the FC65-G. Differences of up to − 6.26% output factor were observed for the Stealth chamber and up to − 0.56% for the CC-13 ionization chamber (IBA) in the 3 × 3 cm(2) field. Our study confirmed the possibility of using Stealth chambers for relative dosimetry measurement in QA. Nature Publishing Group UK 2023-10-21 /pmc/articles/PMC10590446/ /pubmed/37865666 http://dx.doi.org/10.1038/s41598-023-45114-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Choi, Dong Hyeok
Kim, Jin Sung
Lee, Rena
Ahn, So Hyun
Ahn, Woo Sang
Dosimetric verification of annual quality assurance for a linear accelerator using a transmission type detector
title Dosimetric verification of annual quality assurance for a linear accelerator using a transmission type detector
title_full Dosimetric verification of annual quality assurance for a linear accelerator using a transmission type detector
title_fullStr Dosimetric verification of annual quality assurance for a linear accelerator using a transmission type detector
title_full_unstemmed Dosimetric verification of annual quality assurance for a linear accelerator using a transmission type detector
title_short Dosimetric verification of annual quality assurance for a linear accelerator using a transmission type detector
title_sort dosimetric verification of annual quality assurance for a linear accelerator using a transmission type detector
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10590446/
https://www.ncbi.nlm.nih.gov/pubmed/37865666
http://dx.doi.org/10.1038/s41598-023-45114-2
work_keys_str_mv AT choidonghyeok dosimetricverificationofannualqualityassuranceforalinearacceleratorusingatransmissiontypedetector
AT kimjinsung dosimetricverificationofannualqualityassuranceforalinearacceleratorusingatransmissiontypedetector
AT leerena dosimetricverificationofannualqualityassuranceforalinearacceleratorusingatransmissiontypedetector
AT ahnsohyun dosimetricverificationofannualqualityassuranceforalinearacceleratorusingatransmissiontypedetector
AT ahnwoosang dosimetricverificationofannualqualityassuranceforalinearacceleratorusingatransmissiontypedetector