Cargando…
The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair
RATIONALE AND OBJECTIVES: Evaluation of the diagnostic value of linearly blended (LB) and virtual monoenergetic images (VMI) reconstruction techniques with and without metal artifacts reduction (MAR) and of adaptive statistical iterative reconstructions (ASIR) in the assessment of target vessels aft...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10590777/ https://www.ncbi.nlm.nih.gov/pubmed/37876478 http://dx.doi.org/10.1016/j.heliyon.2023.e20700 |
_version_ | 1785124066087141376 |
---|---|
author | Kazimierczak, Wojciech Nowak, Ewa Kazimierczak, Natalia Jankowski, Tomasz Jankowska, Agnieszka Serafin, Zbigniew |
author_facet | Kazimierczak, Wojciech Nowak, Ewa Kazimierczak, Natalia Jankowski, Tomasz Jankowska, Agnieszka Serafin, Zbigniew |
author_sort | Kazimierczak, Wojciech |
collection | PubMed |
description | RATIONALE AND OBJECTIVES: Evaluation of the diagnostic value of linearly blended (LB) and virtual monoenergetic images (VMI) reconstruction techniques with and without metal artifacts reduction (MAR) and of adaptive statistical iterative reconstructions (ASIR) in the assessment of target vessels after branched/fenestrated endovascular aortic repair (f/brEVAR) procedures. MATERIALS AND METHODS: CT scans of 28 patients were used in this study. Arterial phase of examination was obtained using a dual-energy fast-kVp switching scanner. CT numbers in the aorta, celiac trunk, superior mesenteric artery, and renal arteries were measured in the following reconstructions: LB, VMI 60 keV, VMI MAR 60 keV, VMI ASIR 60 % 60 keV. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated for each reconstruction. Luminal diameters (measurements at 2 levels of stent) and subjective image quality (5-point Likert scale) were assessed (2 readers, blinded to the type of reconstruction). RESULTS: The highest mean values of CNR and SNR in vascular structures were obtained in VMI MAR 60 keV (CNR 12.526 ± 2.46, SNR 17.398 ± 2.52), lower in VMI 60 keV (CNR 11.508 ± 2.01, SNR 16.524 ± 2.07) and VMI ASIR (CNR 11.086 ± 1.78, SNR 15.928 ± 1.82), and the lowest in LB (CNR 6.808 ± 0.79, SNR 11.492 ± 0.79) reconstructions. There were no statistically significant differences in the measurements of the stent width between reconstructions (p > 0.05). The highest subjective image quality was obtained in the ASIR VMI (4.25 ± 0.44) and the lowest in the MAR VMI (1.57 ± 0.5) reconstruction. CONCLUSION: Despite obtaining the highest values of SNR and CNR in the MAR VMI reconstruction, the subjective diagnostic value was the lowest for this technique due to significant artifacts. The type of reconstruction did not significantly affect vessel diameter measurements (p > 0.05). Iterative reconstructions raised both objective and subjective image quality. |
format | Online Article Text |
id | pubmed-10590777 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-105907772023-10-24 The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair Kazimierczak, Wojciech Nowak, Ewa Kazimierczak, Natalia Jankowski, Tomasz Jankowska, Agnieszka Serafin, Zbigniew Heliyon Research Article RATIONALE AND OBJECTIVES: Evaluation of the diagnostic value of linearly blended (LB) and virtual monoenergetic images (VMI) reconstruction techniques with and without metal artifacts reduction (MAR) and of adaptive statistical iterative reconstructions (ASIR) in the assessment of target vessels after branched/fenestrated endovascular aortic repair (f/brEVAR) procedures. MATERIALS AND METHODS: CT scans of 28 patients were used in this study. Arterial phase of examination was obtained using a dual-energy fast-kVp switching scanner. CT numbers in the aorta, celiac trunk, superior mesenteric artery, and renal arteries were measured in the following reconstructions: LB, VMI 60 keV, VMI MAR 60 keV, VMI ASIR 60 % 60 keV. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated for each reconstruction. Luminal diameters (measurements at 2 levels of stent) and subjective image quality (5-point Likert scale) were assessed (2 readers, blinded to the type of reconstruction). RESULTS: The highest mean values of CNR and SNR in vascular structures were obtained in VMI MAR 60 keV (CNR 12.526 ± 2.46, SNR 17.398 ± 2.52), lower in VMI 60 keV (CNR 11.508 ± 2.01, SNR 16.524 ± 2.07) and VMI ASIR (CNR 11.086 ± 1.78, SNR 15.928 ± 1.82), and the lowest in LB (CNR 6.808 ± 0.79, SNR 11.492 ± 0.79) reconstructions. There were no statistically significant differences in the measurements of the stent width between reconstructions (p > 0.05). The highest subjective image quality was obtained in the ASIR VMI (4.25 ± 0.44) and the lowest in the MAR VMI (1.57 ± 0.5) reconstruction. CONCLUSION: Despite obtaining the highest values of SNR and CNR in the MAR VMI reconstruction, the subjective diagnostic value was the lowest for this technique due to significant artifacts. The type of reconstruction did not significantly affect vessel diameter measurements (p > 0.05). Iterative reconstructions raised both objective and subjective image quality. Elsevier 2023-10-12 /pmc/articles/PMC10590777/ /pubmed/37876478 http://dx.doi.org/10.1016/j.heliyon.2023.e20700 Text en © 2023 Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Kazimierczak, Wojciech Nowak, Ewa Kazimierczak, Natalia Jankowski, Tomasz Jankowska, Agnieszka Serafin, Zbigniew The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair |
title | The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair |
title_full | The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair |
title_fullStr | The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair |
title_full_unstemmed | The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair |
title_short | The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair |
title_sort | value of metal artifact reduction and iterative algorithms in dual energy ct angiography in patients after complex endovascular aortic aneurysm repair |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10590777/ https://www.ncbi.nlm.nih.gov/pubmed/37876478 http://dx.doi.org/10.1016/j.heliyon.2023.e20700 |
work_keys_str_mv | AT kazimierczakwojciech thevalueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT nowakewa thevalueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT kazimierczaknatalia thevalueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT jankowskitomasz thevalueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT jankowskaagnieszka thevalueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT serafinzbigniew thevalueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT kazimierczakwojciech valueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT nowakewa valueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT kazimierczaknatalia valueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT jankowskitomasz valueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT jankowskaagnieszka valueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair AT serafinzbigniew valueofmetalartifactreductionanditerativealgorithmsindualenergyctangiographyinpatientsaftercomplexendovascularaorticaneurysmrepair |