Cargando…
Performance of hydrocarbon refrigerants in a refrigerator with liquid line magnet and CNT nano-lubricant
The issues of flammability associated with A3-class hydrocarbon-based refrigerants are controllable by limiting their mass charges. However, these reductions in their mass charge below certain limits deteriorate their performance efficiency. In this experimental study, we analyzed the effects of a l...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10590801/ https://www.ncbi.nlm.nih.gov/pubmed/37876452 http://dx.doi.org/10.1016/j.heliyon.2023.e20832 |
_version_ | 1785124073614868480 |
---|---|
author | Adelekan, D.S. Ohunakin, O.S. Oseahon, O.I. Nekabari, F.N. Nkiko, M.O. Odunfa, M.K. |
author_facet | Adelekan, D.S. Ohunakin, O.S. Oseahon, O.I. Nekabari, F.N. Nkiko, M.O. Odunfa, M.K. |
author_sort | Adelekan, D.S. |
collection | PubMed |
description | The issues of flammability associated with A3-class hydrocarbon-based refrigerants are controllable by limiting their mass charges. However, these reductions in their mass charge below certain limits deteriorate their performance efficiency. In this experimental study, we analyzed the effects of a liquid line magnetic field (Mag), multi-wall carbon nanotube (CNT) nano-lubricant, and the combination of both (Mag-Nano) on the performance of a very low mass charge (i.e., 30 g) of R600a and LPG refrigerants, as a replacement to the 100 g R134a refrigerant in a domestic refrigeration system. The refrigerants were tested with and without CNT nano-lubricant (pure), two pairs of 3000 Gs liquid line mounted O ring N50 permanent magnets (Mag), 0.2 g/L concentration of CNT nano-lubricant (Nano), and in combination with a liquid line magnetic field and CNT nano-lubricant (Mag-Nano). The performance evaluation of the refrigerants includes the determination of coefficient of performance (COP), evaporator air temperature, volumetric refrigeration capacity, instantaneous power consumption, cumulative energy consumption, and energy cost. A reduction in the COP of R600a and LPG was observed to be about 11–42% and 14–26%, respectively, when compared to R134a. The R134a refrigerant had the lowest evaporator air temperature of −24.5 °C and the highest instantaneous power consumption of 74.6 W. The R600a-Mag-Nano refrigerant is the most efficient option, having the lowest instantaneous power consumption, energy cost, and cumulative energy consumption. The adoption of hydrocarbon refrigerants is more cost-effective than using the R134a refrigerant, resulting in a cost saving of about 8–26%. In conclusion, the proposed methods adopted to enhance the performance of refrigeration system, are very safe and effective. |
format | Online Article Text |
id | pubmed-10590801 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-105908012023-10-24 Performance of hydrocarbon refrigerants in a refrigerator with liquid line magnet and CNT nano-lubricant Adelekan, D.S. Ohunakin, O.S. Oseahon, O.I. Nekabari, F.N. Nkiko, M.O. Odunfa, M.K. Heliyon Research Article The issues of flammability associated with A3-class hydrocarbon-based refrigerants are controllable by limiting their mass charges. However, these reductions in their mass charge below certain limits deteriorate their performance efficiency. In this experimental study, we analyzed the effects of a liquid line magnetic field (Mag), multi-wall carbon nanotube (CNT) nano-lubricant, and the combination of both (Mag-Nano) on the performance of a very low mass charge (i.e., 30 g) of R600a and LPG refrigerants, as a replacement to the 100 g R134a refrigerant in a domestic refrigeration system. The refrigerants were tested with and without CNT nano-lubricant (pure), two pairs of 3000 Gs liquid line mounted O ring N50 permanent magnets (Mag), 0.2 g/L concentration of CNT nano-lubricant (Nano), and in combination with a liquid line magnetic field and CNT nano-lubricant (Mag-Nano). The performance evaluation of the refrigerants includes the determination of coefficient of performance (COP), evaporator air temperature, volumetric refrigeration capacity, instantaneous power consumption, cumulative energy consumption, and energy cost. A reduction in the COP of R600a and LPG was observed to be about 11–42% and 14–26%, respectively, when compared to R134a. The R134a refrigerant had the lowest evaporator air temperature of −24.5 °C and the highest instantaneous power consumption of 74.6 W. The R600a-Mag-Nano refrigerant is the most efficient option, having the lowest instantaneous power consumption, energy cost, and cumulative energy consumption. The adoption of hydrocarbon refrigerants is more cost-effective than using the R134a refrigerant, resulting in a cost saving of about 8–26%. In conclusion, the proposed methods adopted to enhance the performance of refrigeration system, are very safe and effective. Elsevier 2023-10-12 /pmc/articles/PMC10590801/ /pubmed/37876452 http://dx.doi.org/10.1016/j.heliyon.2023.e20832 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Adelekan, D.S. Ohunakin, O.S. Oseahon, O.I. Nekabari, F.N. Nkiko, M.O. Odunfa, M.K. Performance of hydrocarbon refrigerants in a refrigerator with liquid line magnet and CNT nano-lubricant |
title | Performance of hydrocarbon refrigerants in a refrigerator with liquid line magnet and CNT nano-lubricant |
title_full | Performance of hydrocarbon refrigerants in a refrigerator with liquid line magnet and CNT nano-lubricant |
title_fullStr | Performance of hydrocarbon refrigerants in a refrigerator with liquid line magnet and CNT nano-lubricant |
title_full_unstemmed | Performance of hydrocarbon refrigerants in a refrigerator with liquid line magnet and CNT nano-lubricant |
title_short | Performance of hydrocarbon refrigerants in a refrigerator with liquid line magnet and CNT nano-lubricant |
title_sort | performance of hydrocarbon refrigerants in a refrigerator with liquid line magnet and cnt nano-lubricant |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10590801/ https://www.ncbi.nlm.nih.gov/pubmed/37876452 http://dx.doi.org/10.1016/j.heliyon.2023.e20832 |
work_keys_str_mv | AT adelekands performanceofhydrocarbonrefrigerantsinarefrigeratorwithliquidlinemagnetandcntnanolubricant AT ohunakinos performanceofhydrocarbonrefrigerantsinarefrigeratorwithliquidlinemagnetandcntnanolubricant AT oseahonoi performanceofhydrocarbonrefrigerantsinarefrigeratorwithliquidlinemagnetandcntnanolubricant AT nekabarifn performanceofhydrocarbonrefrigerantsinarefrigeratorwithliquidlinemagnetandcntnanolubricant AT nkikomo performanceofhydrocarbonrefrigerantsinarefrigeratorwithliquidlinemagnetandcntnanolubricant AT odunfamk performanceofhydrocarbonrefrigerantsinarefrigeratorwithliquidlinemagnetandcntnanolubricant |