Cargando…

Screening for osteoporosis based on IQon spectral CT virtual low monoenergetic images: Comparison with conventional 120 kVp images()

OBJECTIVES: To explore the differences between low kiloelectron volt (keV) virtual monoenergetic images (VMIs) using IQon spectral CT and conventional CT (120 kVp) in the diagnosis of osteoporosis. METHODS: This retrospective study included 317 patients who underwent IQon spectral CT and dual-energy...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Hehui, Wei, Wen, Qian, Baoxin, Wu, Daoqin, Zheng, Cunhong, Li, Honghua, Tang, Jinsong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10590932/
https://www.ncbi.nlm.nih.gov/pubmed/37876473
http://dx.doi.org/10.1016/j.heliyon.2023.e20750
_version_ 1785124107970412544
author Zhang, Hehui
Wei, Wen
Qian, Baoxin
Wu, Daoqin
Zheng, Cunhong
Li, Honghua
Tang, Jinsong
author_facet Zhang, Hehui
Wei, Wen
Qian, Baoxin
Wu, Daoqin
Zheng, Cunhong
Li, Honghua
Tang, Jinsong
author_sort Zhang, Hehui
collection PubMed
description OBJECTIVES: To explore the differences between low kiloelectron volt (keV) virtual monoenergetic images (VMIs) using IQon spectral CT and conventional CT (120 kVp) in the diagnosis of osteoporosis. METHODS: This retrospective study included 317 patients who underwent IQon spectral CT and dual-energy X-ray absorptiometry (DXA) examination. Commercial deep learning–based software was used for the fully automated extraction of the CT values of the first to fourth lumbar vertebrae (L1–L4) from two different low-keV levels (including 40/70 keV) VMIs and conventional 120 kVp images. The DXA examination results served as the standard of reference (normal [T-score ≥ −1], osteopenia [-2.5 < T-score < −1], and osteoporosis [T-score < −2.5]). Osteoporosis diagnosis models were constructed using machine learning classifiers (logistic regression, support vector machine, random forest, XGBoost, and multilayer perceptron) based on the average CT values of L1–L4. The area under the receiver operating characteristic curve (AUC) and DeLong test were performed to compare differences in the performance of the osteoporosis diagnosis model between virtual low-keV VMIs and standard 120 kVp images. RESULTS: Random forest-based prediction model obtained good overall performance among all classifiers, and macro/micro average AUC values of 0.820/840, 0.834/853, and 0.831/852 were obtained based on 40/70 keV and 120 kVp images, respectively. The model presented no significant difference between low-keV VMIs and standard 120 kVp images for the diagnosis of osteoporosis (p > 0.05). CONCLUSIONS: The performance of the osteoporosis diagnosis model using IQon spectral CT simulating the low tube voltage scanning condition (less than 120 kVp) was also satisfactory. Bone density screening evaluation can be performed with a combination of low-dose lung scanning CT, greatly reducing the radiation dose without affecting the diagnosis.
format Online
Article
Text
id pubmed-10590932
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-105909322023-10-24 Screening for osteoporosis based on IQon spectral CT virtual low monoenergetic images: Comparison with conventional 120 kVp images() Zhang, Hehui Wei, Wen Qian, Baoxin Wu, Daoqin Zheng, Cunhong Li, Honghua Tang, Jinsong Heliyon Research Article OBJECTIVES: To explore the differences between low kiloelectron volt (keV) virtual monoenergetic images (VMIs) using IQon spectral CT and conventional CT (120 kVp) in the diagnosis of osteoporosis. METHODS: This retrospective study included 317 patients who underwent IQon spectral CT and dual-energy X-ray absorptiometry (DXA) examination. Commercial deep learning–based software was used for the fully automated extraction of the CT values of the first to fourth lumbar vertebrae (L1–L4) from two different low-keV levels (including 40/70 keV) VMIs and conventional 120 kVp images. The DXA examination results served as the standard of reference (normal [T-score ≥ −1], osteopenia [-2.5 < T-score < −1], and osteoporosis [T-score < −2.5]). Osteoporosis diagnosis models were constructed using machine learning classifiers (logistic regression, support vector machine, random forest, XGBoost, and multilayer perceptron) based on the average CT values of L1–L4. The area under the receiver operating characteristic curve (AUC) and DeLong test were performed to compare differences in the performance of the osteoporosis diagnosis model between virtual low-keV VMIs and standard 120 kVp images. RESULTS: Random forest-based prediction model obtained good overall performance among all classifiers, and macro/micro average AUC values of 0.820/840, 0.834/853, and 0.831/852 were obtained based on 40/70 keV and 120 kVp images, respectively. The model presented no significant difference between low-keV VMIs and standard 120 kVp images for the diagnosis of osteoporosis (p > 0.05). CONCLUSIONS: The performance of the osteoporosis diagnosis model using IQon spectral CT simulating the low tube voltage scanning condition (less than 120 kVp) was also satisfactory. Bone density screening evaluation can be performed with a combination of low-dose lung scanning CT, greatly reducing the radiation dose without affecting the diagnosis. Elsevier 2023-10-12 /pmc/articles/PMC10590932/ /pubmed/37876473 http://dx.doi.org/10.1016/j.heliyon.2023.e20750 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Zhang, Hehui
Wei, Wen
Qian, Baoxin
Wu, Daoqin
Zheng, Cunhong
Li, Honghua
Tang, Jinsong
Screening for osteoporosis based on IQon spectral CT virtual low monoenergetic images: Comparison with conventional 120 kVp images()
title Screening for osteoporosis based on IQon spectral CT virtual low monoenergetic images: Comparison with conventional 120 kVp images()
title_full Screening for osteoporosis based on IQon spectral CT virtual low monoenergetic images: Comparison with conventional 120 kVp images()
title_fullStr Screening for osteoporosis based on IQon spectral CT virtual low monoenergetic images: Comparison with conventional 120 kVp images()
title_full_unstemmed Screening for osteoporosis based on IQon spectral CT virtual low monoenergetic images: Comparison with conventional 120 kVp images()
title_short Screening for osteoporosis based on IQon spectral CT virtual low monoenergetic images: Comparison with conventional 120 kVp images()
title_sort screening for osteoporosis based on iqon spectral ct virtual low monoenergetic images: comparison with conventional 120 kvp images()
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10590932/
https://www.ncbi.nlm.nih.gov/pubmed/37876473
http://dx.doi.org/10.1016/j.heliyon.2023.e20750
work_keys_str_mv AT zhanghehui screeningforosteoporosisbasedoniqonspectralctvirtuallowmonoenergeticimagescomparisonwithconventional120kvpimages
AT weiwen screeningforosteoporosisbasedoniqonspectralctvirtuallowmonoenergeticimagescomparisonwithconventional120kvpimages
AT qianbaoxin screeningforosteoporosisbasedoniqonspectralctvirtuallowmonoenergeticimagescomparisonwithconventional120kvpimages
AT wudaoqin screeningforosteoporosisbasedoniqonspectralctvirtuallowmonoenergeticimagescomparisonwithconventional120kvpimages
AT zhengcunhong screeningforosteoporosisbasedoniqonspectralctvirtuallowmonoenergeticimagescomparisonwithconventional120kvpimages
AT lihonghua screeningforosteoporosisbasedoniqonspectralctvirtuallowmonoenergeticimagescomparisonwithconventional120kvpimages
AT tangjinsong screeningforosteoporosisbasedoniqonspectralctvirtuallowmonoenergeticimagescomparisonwithconventional120kvpimages