Cargando…

Examining CLABSI rates by central-line type

Background: Central-line–associated bloodstream infections (CLABSIs) are linked to increased morbidity and mortality, longer hospital stays, and significantly higher healthcare costs. Infection prevention guidelines recommend line placement in specific insertion locations over others because of the...

Descripción completa

Detalles Bibliográficos
Autores principales: DiBiase, Lauren, Summerlin-Long, Shelley, Stancill, Lisa, Vavalle, Emily Sickbert-Bennett, Teal, Lisa, Weber, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10594209/
http://dx.doi.org/10.1017/ash.2023.288
_version_ 1785124597167816704
author DiBiase, Lauren
Summerlin-Long, Shelley
Stancill, Lisa
Vavalle, Emily Sickbert-Bennett
Teal, Lisa
Weber, David
author_facet DiBiase, Lauren
Summerlin-Long, Shelley
Stancill, Lisa
Vavalle, Emily Sickbert-Bennett
Teal, Lisa
Weber, David
author_sort DiBiase, Lauren
collection PubMed
description Background: Central-line–associated bloodstream infections (CLABSIs) are linked to increased morbidity and mortality, longer hospital stays, and significantly higher healthcare costs. Infection prevention guidelines recommend line placement in specific insertion locations over others because of the relative risk of infection. The purpose of this study was to assess CLABSI rates by line type to determine whether some central lines had a lower risk of infection and should be recommended over others given similar clinical indications. Methods: At UNC Hospitals, data were obtained on central lines across a 3-year period (FY20–FY22) from the EMR (Epic Systems). Central lines were categorized as apheresis catheters, CVC lines (single, double, or triple lumen), hemodialysis catheters, introducer lines, pulmonary artery (PA) catheters, PICC lines (single, double, or triple lumen), port-a-catheters, trialysis catheters, or umbilical lines. The line type(s) associated with each CLABSI during the same period were recorded, and CLABSI rates by line type per 1,000 central-line days were calculated using SAS software. If an infection had >1 central-line device type associated, the infection was counted twice when calculating the CLABSI rate by line type. We calculated 95% CIs for each point estimate to assess for statistically significant differences in rates by line type. Results: During FY20–FY22, there were 264,425 central-line days and 458 CLABSIs, for an overall CLABSI rate of 1.73 CLABSIs per 1,000 central-line days. Also, 16% of patients with a CLABSI had >1 type of central line in place. Stratified data on CLABSI rates by each central-line type is presented in the Figure. CLABSI rates were highest in patients with apheresis lines (6.22; 95% CI, 3.96–9.35) and PA catheters (6.22; 95% CI, 3.54–10.20), and the lowest CLABSI rates occurred in patients with PICC lines (1.44; 95% CI, 1.19–1.73) and port-a-catheters (1.14; 95% CI, 0.89, 1.45). For both CVC and PICC lines, as the number of lumens increased from single to triple, CLABSI rates increased, from 0.91 to 2.63 and from 0.57 to 1.20, respectively. Conclusions: At our hospital, different types of central lines were associated with statistically higher CLABSI rates. Additionally, a higher number of lumens (triple vs single) in CVC and PICC lines were also associated with statistically higher CLABSI rates. These findings reinforce the importance of considering central-line type and number of lumens to minimize risk of CLABSI while ensuring that patients have the best line type based on their clinical needs. Disclosures: None
format Online
Article
Text
id pubmed-10594209
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-105942092023-10-25 Examining CLABSI rates by central-line type DiBiase, Lauren Summerlin-Long, Shelley Stancill, Lisa Vavalle, Emily Sickbert-Bennett Teal, Lisa Weber, David Antimicrob Steward Healthc Epidemiol Clabsi Background: Central-line–associated bloodstream infections (CLABSIs) are linked to increased morbidity and mortality, longer hospital stays, and significantly higher healthcare costs. Infection prevention guidelines recommend line placement in specific insertion locations over others because of the relative risk of infection. The purpose of this study was to assess CLABSI rates by line type to determine whether some central lines had a lower risk of infection and should be recommended over others given similar clinical indications. Methods: At UNC Hospitals, data were obtained on central lines across a 3-year period (FY20–FY22) from the EMR (Epic Systems). Central lines were categorized as apheresis catheters, CVC lines (single, double, or triple lumen), hemodialysis catheters, introducer lines, pulmonary artery (PA) catheters, PICC lines (single, double, or triple lumen), port-a-catheters, trialysis catheters, or umbilical lines. The line type(s) associated with each CLABSI during the same period were recorded, and CLABSI rates by line type per 1,000 central-line days were calculated using SAS software. If an infection had >1 central-line device type associated, the infection was counted twice when calculating the CLABSI rate by line type. We calculated 95% CIs for each point estimate to assess for statistically significant differences in rates by line type. Results: During FY20–FY22, there were 264,425 central-line days and 458 CLABSIs, for an overall CLABSI rate of 1.73 CLABSIs per 1,000 central-line days. Also, 16% of patients with a CLABSI had >1 type of central line in place. Stratified data on CLABSI rates by each central-line type is presented in the Figure. CLABSI rates were highest in patients with apheresis lines (6.22; 95% CI, 3.96–9.35) and PA catheters (6.22; 95% CI, 3.54–10.20), and the lowest CLABSI rates occurred in patients with PICC lines (1.44; 95% CI, 1.19–1.73) and port-a-catheters (1.14; 95% CI, 0.89, 1.45). For both CVC and PICC lines, as the number of lumens increased from single to triple, CLABSI rates increased, from 0.91 to 2.63 and from 0.57 to 1.20, respectively. Conclusions: At our hospital, different types of central lines were associated with statistically higher CLABSI rates. Additionally, a higher number of lumens (triple vs single) in CVC and PICC lines were also associated with statistically higher CLABSI rates. These findings reinforce the importance of considering central-line type and number of lumens to minimize risk of CLABSI while ensuring that patients have the best line type based on their clinical needs. Disclosures: None Cambridge University Press 2023-09-29 /pmc/articles/PMC10594209/ http://dx.doi.org/10.1017/ash.2023.288 Text en © The Society for Healthcare Epidemiology of America 2023 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clabsi
DiBiase, Lauren
Summerlin-Long, Shelley
Stancill, Lisa
Vavalle, Emily Sickbert-Bennett
Teal, Lisa
Weber, David
Examining CLABSI rates by central-line type
title Examining CLABSI rates by central-line type
title_full Examining CLABSI rates by central-line type
title_fullStr Examining CLABSI rates by central-line type
title_full_unstemmed Examining CLABSI rates by central-line type
title_short Examining CLABSI rates by central-line type
title_sort examining clabsi rates by central-line type
topic Clabsi
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10594209/
http://dx.doi.org/10.1017/ash.2023.288
work_keys_str_mv AT dibiaselauren examiningclabsiratesbycentrallinetype
AT summerlinlongshelley examiningclabsiratesbycentrallinetype
AT stancilllisa examiningclabsiratesbycentrallinetype
AT vavalleemilysickbertbennett examiningclabsiratesbycentrallinetype
AT teallisa examiningclabsiratesbycentrallinetype
AT weberdavid examiningclabsiratesbycentrallinetype