Cargando…

Validation of automated surveillance of healthcare-associated infections using electronic screening algorithms

Background: Surveillance of healthcare-associated infection (HAI) is the basis of infection prevention programs. However, manual review of medical records is a labor-intensive and time-consuming process. We evaluated the diagnostic performance of automated surveillance of HAI using electronic screen...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Hyunju, Ryu, Seunghee, Yang, Hyejin, Lee, Jeongyoung, Park, Soyeon, Kim, Eun Ok, Jung, Jiwon, Kima, Sung-Han
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10594252/
http://dx.doi.org/10.1017/ash.2023.375
_version_ 1785124606979342336
author Lee, Hyunju
Ryu, Seunghee
Yang, Hyejin
Lee, Jeongyoung
Park, Soyeon
Kim, Eun Ok
Jung, Jiwon
Kima, Sung-Han
author_facet Lee, Hyunju
Ryu, Seunghee
Yang, Hyejin
Lee, Jeongyoung
Park, Soyeon
Kim, Eun Ok
Jung, Jiwon
Kima, Sung-Han
author_sort Lee, Hyunju
collection PubMed
description Background: Surveillance of healthcare-associated infection (HAI) is the basis of infection prevention programs. However, manual review of medical records is a labor-intensive and time-consuming process. We evaluated the diagnostic performance of automated surveillance of HAI using electronic screening algorithms. Methods: Between April and June 2022, we conducted surveillance of HAI manually and automatically using electronic screening algorithm on 75 units (general medical and surgical wards and ICUs) in a 2,700-bed, tertiary-care hospital in South Korea. Algorithms for surveillance of HAI were developed accordance with NHSN surveillance definitions (Fig. 1). Catheter-associated urinary tract infections (CAUTIs) were automatically detected when eligible pathogen and fever (>38°C) were matched within infection window period. Other specific types of infection were automatically classified based on laboratory results that met NHSN criteria. After the algorithm showed possible cases that met laboratory-confirmed bloodstream infection (LCBI) criteria, we excluded secondary BSIs using the automatic surveillance algorithm. We analyzed sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the automated surveillance system compared to manual surveillance. Results: An algorithm for detecting CAUTI showed 98.7% sensitivity (78 of 79), 100.0% specificity (2,443 of 2,443), 100.0% PPV (78 of 78), and 100.0% NPV (2,443 of 2,444). For CLABSI, the algorithm had 97.3% sensitivity (214 of 220), 98.3% specificity (5,759 of 5,861), 67.7% PPV (214 of 316), and 99.9% NPV (5,759 of 5,765). In total, 102 cases of possible CLABSI were identified by the algorithm, and 76 (74.5%) were eventually diagnosed as secondary BSIs. Also, by chart review, 20 BSIs (19.6%) were present on arrival in ER (ER-POA). In 4 cases (3.9%), an original pathogen reoccurred in a repeated infection timeframe (RIT), and 2 cases (2%) were mucosal barrier injury-LCBI (MBI-LCBI). When we additionally performed manual surveillance for intra-abdominal infection secondary BSI, ER-POA, and assigning pathogen to original BSI in RIT, PPV increased to 87.7% (214 of 244). Conclusions: Algorithm for automated surveillance of CAUTI had good performance; however, automated surveillance of CLABSI was suboptimal. More elaborate screening algorithm for diagnosis CLABSI is needed, and further studies are needed to determine whether an automated surveillance system can reduce workload for surveillance of HAI. Disclosures: None
format Online
Article
Text
id pubmed-10594252
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-105942522023-10-25 Validation of automated surveillance of healthcare-associated infections using electronic screening algorithms Lee, Hyunju Ryu, Seunghee Yang, Hyejin Lee, Jeongyoung Park, Soyeon Kim, Eun Ok Jung, Jiwon Kima, Sung-Han Antimicrob Steward Healthc Epidemiol Surveillance/Public Health Background: Surveillance of healthcare-associated infection (HAI) is the basis of infection prevention programs. However, manual review of medical records is a labor-intensive and time-consuming process. We evaluated the diagnostic performance of automated surveillance of HAI using electronic screening algorithms. Methods: Between April and June 2022, we conducted surveillance of HAI manually and automatically using electronic screening algorithm on 75 units (general medical and surgical wards and ICUs) in a 2,700-bed, tertiary-care hospital in South Korea. Algorithms for surveillance of HAI were developed accordance with NHSN surveillance definitions (Fig. 1). Catheter-associated urinary tract infections (CAUTIs) were automatically detected when eligible pathogen and fever (>38°C) were matched within infection window period. Other specific types of infection were automatically classified based on laboratory results that met NHSN criteria. After the algorithm showed possible cases that met laboratory-confirmed bloodstream infection (LCBI) criteria, we excluded secondary BSIs using the automatic surveillance algorithm. We analyzed sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the automated surveillance system compared to manual surveillance. Results: An algorithm for detecting CAUTI showed 98.7% sensitivity (78 of 79), 100.0% specificity (2,443 of 2,443), 100.0% PPV (78 of 78), and 100.0% NPV (2,443 of 2,444). For CLABSI, the algorithm had 97.3% sensitivity (214 of 220), 98.3% specificity (5,759 of 5,861), 67.7% PPV (214 of 316), and 99.9% NPV (5,759 of 5,765). In total, 102 cases of possible CLABSI were identified by the algorithm, and 76 (74.5%) were eventually diagnosed as secondary BSIs. Also, by chart review, 20 BSIs (19.6%) were present on arrival in ER (ER-POA). In 4 cases (3.9%), an original pathogen reoccurred in a repeated infection timeframe (RIT), and 2 cases (2%) were mucosal barrier injury-LCBI (MBI-LCBI). When we additionally performed manual surveillance for intra-abdominal infection secondary BSI, ER-POA, and assigning pathogen to original BSI in RIT, PPV increased to 87.7% (214 of 244). Conclusions: Algorithm for automated surveillance of CAUTI had good performance; however, automated surveillance of CLABSI was suboptimal. More elaborate screening algorithm for diagnosis CLABSI is needed, and further studies are needed to determine whether an automated surveillance system can reduce workload for surveillance of HAI. Disclosures: None Cambridge University Press 2023-09-29 /pmc/articles/PMC10594252/ http://dx.doi.org/10.1017/ash.2023.375 Text en © The Society for Healthcare Epidemiology of America 2023 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Surveillance/Public Health
Lee, Hyunju
Ryu, Seunghee
Yang, Hyejin
Lee, Jeongyoung
Park, Soyeon
Kim, Eun Ok
Jung, Jiwon
Kima, Sung-Han
Validation of automated surveillance of healthcare-associated infections using electronic screening algorithms
title Validation of automated surveillance of healthcare-associated infections using electronic screening algorithms
title_full Validation of automated surveillance of healthcare-associated infections using electronic screening algorithms
title_fullStr Validation of automated surveillance of healthcare-associated infections using electronic screening algorithms
title_full_unstemmed Validation of automated surveillance of healthcare-associated infections using electronic screening algorithms
title_short Validation of automated surveillance of healthcare-associated infections using electronic screening algorithms
title_sort validation of automated surveillance of healthcare-associated infections using electronic screening algorithms
topic Surveillance/Public Health
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10594252/
http://dx.doi.org/10.1017/ash.2023.375
work_keys_str_mv AT leehyunju validationofautomatedsurveillanceofhealthcareassociatedinfectionsusingelectronicscreeningalgorithms
AT ryuseunghee validationofautomatedsurveillanceofhealthcareassociatedinfectionsusingelectronicscreeningalgorithms
AT yanghyejin validationofautomatedsurveillanceofhealthcareassociatedinfectionsusingelectronicscreeningalgorithms
AT leejeongyoung validationofautomatedsurveillanceofhealthcareassociatedinfectionsusingelectronicscreeningalgorithms
AT parksoyeon validationofautomatedsurveillanceofhealthcareassociatedinfectionsusingelectronicscreeningalgorithms
AT kimeunok validationofautomatedsurveillanceofhealthcareassociatedinfectionsusingelectronicscreeningalgorithms
AT jungjiwon validationofautomatedsurveillanceofhealthcareassociatedinfectionsusingelectronicscreeningalgorithms
AT kimasunghan validationofautomatedsurveillanceofhealthcareassociatedinfectionsusingelectronicscreeningalgorithms