Cargando…

Arterial spin labeling (ASL-MRI) versus fluorodeoxyglucose-PET (FDG-PET) in diagnosing dementia: a systematic review and meta-analysis

BACKGROUND: Dementia is generally caused by neurodegenerative diseases affecting the brain, which leads to a progressive neurocognitive decline characterized by inability to perform major higher functioning tasks. Fluorodeoxyglucose-positron emission tomography (FDG-PET) scan is one of the main imag...

Descripción completa

Detalles Bibliográficos
Autores principales: Haidar, Hiba, Majzoub, Rania El, Hajeer, Shorouk, Abbas, Linda Abou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10594722/
https://www.ncbi.nlm.nih.gov/pubmed/37875879
http://dx.doi.org/10.1186/s12883-023-03432-y
_version_ 1785124708741545984
author Haidar, Hiba
Majzoub, Rania El
Hajeer, Shorouk
Abbas, Linda Abou
author_facet Haidar, Hiba
Majzoub, Rania El
Hajeer, Shorouk
Abbas, Linda Abou
author_sort Haidar, Hiba
collection PubMed
description BACKGROUND: Dementia is generally caused by neurodegenerative diseases affecting the brain, which leads to a progressive neurocognitive decline characterized by inability to perform major higher functioning tasks. Fluorodeoxyglucose-positron emission tomography (FDG-PET) scan is one of the main imaging tests performed for diagnostic purposes. However, with FDG-PET being quite expensive and not widely available, an attempt to find an alternative is set. Arterial-spin-labelling magnetic resonance imaging (ASL-MRI) is an increasingly investigated substitute to FDG-PET for the diagnosis of dementia. Thereby, the main purpose of this systematic review and meta-analysis is to compare the diagnostic ability of FDG-PET and ASL-MRI in detecting dementia. METHODS: PRISMA checklist for diagnostic test accuracy was employed in outlining this paper. A literature search was done using several search engines including PubMed, Core, and Cochrane. Two researchers (HH and SH) extracted the essential information from all included articles. Risk of bias was evaluated by the Quality Assessment of Diagnostic Accuracy Studies tool, version 2 (QUADAS-2). A qualitative analysis and summary of studies’ results were provided. In addition, a meta-analysis was executed based on the studies which involved sensitivity and specificity measures of diagnostic accuracy. RESULTS: Fourteen total studies were included in the given review. Qualitative analysis of the articles showed that nine studies demonstrated an overlap between metabolic and perfused brain maps as derived by FDG-PET and ASL-MRI respectively, while the remaining five studies registered significant differences across both modalities, with superiority to FDG-PET. As for the meta-analysis implemented, summary ROC-curve analysis revealed that FDG-PET performed better than ASL-MRI, with pooled sensitivity being significantly higher for FDG-PET. CONCLUSIONS: Comparing the diagnostic value of FDG-PET and ASL-MRI, the results of this systematic review and meta-analysis indicate that FDG-PET still has an advantage over ASL-MRI. Such implication could be related to the technical differences relating to both modalities, with ASL-MRI having lower temporal resolution. It’s worth mentioning that specificity was rather quite similar among both modalities and some studies found an overridden metabolic and perfused images. These findings call for future research to focus their scope of investigation while exploring the diagnostic value of ASL-MRI.
format Online
Article
Text
id pubmed-10594722
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-105947222023-10-25 Arterial spin labeling (ASL-MRI) versus fluorodeoxyglucose-PET (FDG-PET) in diagnosing dementia: a systematic review and meta-analysis Haidar, Hiba Majzoub, Rania El Hajeer, Shorouk Abbas, Linda Abou BMC Neurol Research BACKGROUND: Dementia is generally caused by neurodegenerative diseases affecting the brain, which leads to a progressive neurocognitive decline characterized by inability to perform major higher functioning tasks. Fluorodeoxyglucose-positron emission tomography (FDG-PET) scan is one of the main imaging tests performed for diagnostic purposes. However, with FDG-PET being quite expensive and not widely available, an attempt to find an alternative is set. Arterial-spin-labelling magnetic resonance imaging (ASL-MRI) is an increasingly investigated substitute to FDG-PET for the diagnosis of dementia. Thereby, the main purpose of this systematic review and meta-analysis is to compare the diagnostic ability of FDG-PET and ASL-MRI in detecting dementia. METHODS: PRISMA checklist for diagnostic test accuracy was employed in outlining this paper. A literature search was done using several search engines including PubMed, Core, and Cochrane. Two researchers (HH and SH) extracted the essential information from all included articles. Risk of bias was evaluated by the Quality Assessment of Diagnostic Accuracy Studies tool, version 2 (QUADAS-2). A qualitative analysis and summary of studies’ results were provided. In addition, a meta-analysis was executed based on the studies which involved sensitivity and specificity measures of diagnostic accuracy. RESULTS: Fourteen total studies were included in the given review. Qualitative analysis of the articles showed that nine studies demonstrated an overlap between metabolic and perfused brain maps as derived by FDG-PET and ASL-MRI respectively, while the remaining five studies registered significant differences across both modalities, with superiority to FDG-PET. As for the meta-analysis implemented, summary ROC-curve analysis revealed that FDG-PET performed better than ASL-MRI, with pooled sensitivity being significantly higher for FDG-PET. CONCLUSIONS: Comparing the diagnostic value of FDG-PET and ASL-MRI, the results of this systematic review and meta-analysis indicate that FDG-PET still has an advantage over ASL-MRI. Such implication could be related to the technical differences relating to both modalities, with ASL-MRI having lower temporal resolution. It’s worth mentioning that specificity was rather quite similar among both modalities and some studies found an overridden metabolic and perfused images. These findings call for future research to focus their scope of investigation while exploring the diagnostic value of ASL-MRI. BioMed Central 2023-10-24 /pmc/articles/PMC10594722/ /pubmed/37875879 http://dx.doi.org/10.1186/s12883-023-03432-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Haidar, Hiba
Majzoub, Rania El
Hajeer, Shorouk
Abbas, Linda Abou
Arterial spin labeling (ASL-MRI) versus fluorodeoxyglucose-PET (FDG-PET) in diagnosing dementia: a systematic review and meta-analysis
title Arterial spin labeling (ASL-MRI) versus fluorodeoxyglucose-PET (FDG-PET) in diagnosing dementia: a systematic review and meta-analysis
title_full Arterial spin labeling (ASL-MRI) versus fluorodeoxyglucose-PET (FDG-PET) in diagnosing dementia: a systematic review and meta-analysis
title_fullStr Arterial spin labeling (ASL-MRI) versus fluorodeoxyglucose-PET (FDG-PET) in diagnosing dementia: a systematic review and meta-analysis
title_full_unstemmed Arterial spin labeling (ASL-MRI) versus fluorodeoxyglucose-PET (FDG-PET) in diagnosing dementia: a systematic review and meta-analysis
title_short Arterial spin labeling (ASL-MRI) versus fluorodeoxyglucose-PET (FDG-PET) in diagnosing dementia: a systematic review and meta-analysis
title_sort arterial spin labeling (asl-mri) versus fluorodeoxyglucose-pet (fdg-pet) in diagnosing dementia: a systematic review and meta-analysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10594722/
https://www.ncbi.nlm.nih.gov/pubmed/37875879
http://dx.doi.org/10.1186/s12883-023-03432-y
work_keys_str_mv AT haidarhiba arterialspinlabelingaslmriversusfluorodeoxyglucosepetfdgpetindiagnosingdementiaasystematicreviewandmetaanalysis
AT majzoubraniael arterialspinlabelingaslmriversusfluorodeoxyglucosepetfdgpetindiagnosingdementiaasystematicreviewandmetaanalysis
AT hajeershorouk arterialspinlabelingaslmriversusfluorodeoxyglucosepetfdgpetindiagnosingdementiaasystematicreviewandmetaanalysis
AT abbaslindaabou arterialspinlabelingaslmriversusfluorodeoxyglucosepetfdgpetindiagnosingdementiaasystematicreviewandmetaanalysis