Blood pressure measurement device change in the Healthy Finland health examination survey

BACKGROUND: Blood pressure (BP) measurements in health examination surveys (HESs) are needed for public health monitoring. In Finland, population-based HESs with BP measurements have been performed with mercury sphygmomanometers since the 1960's. The use of oscillometric devices has rendered sp...

Descripción completa

Detalles Bibliográficos
Autores principales: Lehtoranta, L, Palosaari, T, Tolonen, H, Lundqvist, A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10596808/
http://dx.doi.org/10.1093/eurpub/ckad160.1689
_version_ 1785125191994572800
author Lehtoranta, L
Palosaari, T
Tolonen, H
Lundqvist, A
author_facet Lehtoranta, L
Palosaari, T
Tolonen, H
Lundqvist, A
author_sort Lehtoranta, L
collection PubMed
description BACKGROUND: Blood pressure (BP) measurements in health examination surveys (HESs) are needed for public health monitoring. In Finland, population-based HESs with BP measurements have been performed with mercury sphygmomanometers since the 1960's. The use of oscillometric devices has rendered sphygmomanometers impractical for health surveys. This study describes the change in BP measurement method and mean BP values in Finnish HESs. METHODS: 66 000 randomly selected adults living in Finland were invited to the Healthy Finland questionnaire-based health survey in 2022-2023. Of those, 10 000 were asked to participate in a HES including BP, anthropometric, and functional capacity measurements as well as collection of biological samples. Prior to the selection of the new oscillometric BP device, validation studies for devices were evaluated, and the availability was checked. BP measurements were performed using WatchBP Office Vascular (TWIN200 VSR) device. RESULTS: Two consecutive BP measurements were obtained from 3424 participants aged 30 years or older (ongoing until 6/2023). The mean (95% CI) systolic blood pressures (SBP) for men and women were 137.1 (136.2-140.0) and 134.7 mmHg (133.7-135.6), respectively. The corresponding values for diastolic blood pressure (DBP) were 82.3 (81.8-82.8) and 79.3 mmHg (78.9-79.8). The mean difference (95% CI) between the 1st and the 2nd SBP measurements were -2.4 (-2.7- -2.0) and -1.8 (-2.1- -1.4) in men and women, while the corresponding values for DBP were -1.1 (-1.4- -0.9) and -1.2 (-1.5- -1.0). Distribution of measurements was Gaussian apat from some values, that were unlikely to be obtained (SBP: 155, 156, 157; DBP: 96, 99). CONCLUSIONS: Oscillometric BP provide reliable data in HESs. Finnish BP levels may be on the rise. Further reseach is needed to estimate the effects of gaps in the measurement algorithm of TWIN200 VSR and the differences in consecutive measurements. KEY MESSAGES: • In a health examination survey, oscillometric blood pressure measurements led to similar results as with a sphygmomanometer. • Algorithm gaps and smaller difference on successive measurements were seen.
format Online
Article
Text
id pubmed-10596808
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-105968082023-10-25 Blood pressure measurement device change in the Healthy Finland health examination survey Lehtoranta, L Palosaari, T Tolonen, H Lundqvist, A Eur J Public Health Poster Displays BACKGROUND: Blood pressure (BP) measurements in health examination surveys (HESs) are needed for public health monitoring. In Finland, population-based HESs with BP measurements have been performed with mercury sphygmomanometers since the 1960's. The use of oscillometric devices has rendered sphygmomanometers impractical for health surveys. This study describes the change in BP measurement method and mean BP values in Finnish HESs. METHODS: 66 000 randomly selected adults living in Finland were invited to the Healthy Finland questionnaire-based health survey in 2022-2023. Of those, 10 000 were asked to participate in a HES including BP, anthropometric, and functional capacity measurements as well as collection of biological samples. Prior to the selection of the new oscillometric BP device, validation studies for devices were evaluated, and the availability was checked. BP measurements were performed using WatchBP Office Vascular (TWIN200 VSR) device. RESULTS: Two consecutive BP measurements were obtained from 3424 participants aged 30 years or older (ongoing until 6/2023). The mean (95% CI) systolic blood pressures (SBP) for men and women were 137.1 (136.2-140.0) and 134.7 mmHg (133.7-135.6), respectively. The corresponding values for diastolic blood pressure (DBP) were 82.3 (81.8-82.8) and 79.3 mmHg (78.9-79.8). The mean difference (95% CI) between the 1st and the 2nd SBP measurements were -2.4 (-2.7- -2.0) and -1.8 (-2.1- -1.4) in men and women, while the corresponding values for DBP were -1.1 (-1.4- -0.9) and -1.2 (-1.5- -1.0). Distribution of measurements was Gaussian apat from some values, that were unlikely to be obtained (SBP: 155, 156, 157; DBP: 96, 99). CONCLUSIONS: Oscillometric BP provide reliable data in HESs. Finnish BP levels may be on the rise. Further reseach is needed to estimate the effects of gaps in the measurement algorithm of TWIN200 VSR and the differences in consecutive measurements. KEY MESSAGES: • In a health examination survey, oscillometric blood pressure measurements led to similar results as with a sphygmomanometer. • Algorithm gaps and smaller difference on successive measurements were seen. Oxford University Press 2023-10-24 /pmc/articles/PMC10596808/ http://dx.doi.org/10.1093/eurpub/ckad160.1689 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Public Health Association. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Poster Displays
Lehtoranta, L
Palosaari, T
Tolonen, H
Lundqvist, A
Blood pressure measurement device change in the Healthy Finland health examination survey
title Blood pressure measurement device change in the Healthy Finland health examination survey
title_full Blood pressure measurement device change in the Healthy Finland health examination survey
title_fullStr Blood pressure measurement device change in the Healthy Finland health examination survey
title_full_unstemmed Blood pressure measurement device change in the Healthy Finland health examination survey
title_short Blood pressure measurement device change in the Healthy Finland health examination survey
title_sort blood pressure measurement device change in the healthy finland health examination survey
topic Poster Displays
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10596808/
http://dx.doi.org/10.1093/eurpub/ckad160.1689
work_keys_str_mv AT lehtorantal bloodpressuremeasurementdevicechangeinthehealthyfinlandhealthexaminationsurvey
AT palosaarit bloodpressuremeasurementdevicechangeinthehealthyfinlandhealthexaminationsurvey
AT tolonenh bloodpressuremeasurementdevicechangeinthehealthyfinlandhealthexaminationsurvey
AT lundqvista bloodpressuremeasurementdevicechangeinthehealthyfinlandhealthexaminationsurvey