Cargando…
Proximal Femur Endoprosthesis Augmentation with Polymethylmethacrylate and Condylar Plate: A Case Series
INTRODUCTION: Aseptic and septic loosening by mechanical failure is one of the main causes of proximal femur endoprosthesis failure with different clinical consequences such as pain, inflammation, progressive loosening of muscular volume, and strength with functional limitation. We present a case se...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599359/ https://www.ncbi.nlm.nih.gov/pubmed/37885631 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3964 |
_version_ | 1785125751753801728 |
---|---|
author | Gaitán-Lee, Hernando Chavarro, Ingrid P Rincón, Mariana Piñeros Visbal, Nicolle L Leal, Efraím |
author_facet | Gaitán-Lee, Hernando Chavarro, Ingrid P Rincón, Mariana Piñeros Visbal, Nicolle L Leal, Efraím |
author_sort | Gaitán-Lee, Hernando |
collection | PubMed |
description | INTRODUCTION: Aseptic and septic loosening by mechanical failure is one of the main causes of proximal femur endoprosthesis failure with different clinical consequences such as pain, inflammation, progressive loosening of muscular volume, and strength with functional limitation. We present a case series of four patients with aseptic and septic loosening of femur endoprosthesis that was treated with a novel technique that combines different methods to achieve primary stability. CASE REPORT: Four patients with an average age of 49.5 years (35–70 years), two women and two men, were referred to the Orthopedic Surgery Department of the San Ignacio University Hospital of Bogota. Two of them with a history of oncological disease, ruling out a tumor relapse through local images and extension examinations; another patient with a history of firearm injury to the left thigh with multiple secondary complications, which required various reconstructive procedures; and the oldest patient with a history of total hip replacement. The main complaint of the four patients was thigh pain not caused by trauma and initial assessment radiographs of all of them showed signs of loosening of the prosthetic material, with septic etiology in two of the patients and aseptic etiology in the other two. Therefore, they were scheduled for revision surgery of prosthetic components. These patients recover functional status and resolved pain in the early post-operative period and during long-term follow-up. Only one of the patients, time after the surgical procedure, required removal of the osteosynthesis material due to persistent bone infectious process. CONCLUSION: Septic and aseptic loosening is one of the most common complications of proximal femur endoprosthesis, resulting in significant pain and functional decline in patients. We present a novel surgical technique that allows primary stabilization of the construct that allows early rehabilitation, improvement of functionality, and no signs of new loosening. |
format | Online Article Text |
id | pubmed-10599359 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Indian Orthopaedic Research Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-105993592023-10-26 Proximal Femur Endoprosthesis Augmentation with Polymethylmethacrylate and Condylar Plate: A Case Series Gaitán-Lee, Hernando Chavarro, Ingrid P Rincón, Mariana Piñeros Visbal, Nicolle L Leal, Efraím J Orthop Case Rep Case Report INTRODUCTION: Aseptic and septic loosening by mechanical failure is one of the main causes of proximal femur endoprosthesis failure with different clinical consequences such as pain, inflammation, progressive loosening of muscular volume, and strength with functional limitation. We present a case series of four patients with aseptic and septic loosening of femur endoprosthesis that was treated with a novel technique that combines different methods to achieve primary stability. CASE REPORT: Four patients with an average age of 49.5 years (35–70 years), two women and two men, were referred to the Orthopedic Surgery Department of the San Ignacio University Hospital of Bogota. Two of them with a history of oncological disease, ruling out a tumor relapse through local images and extension examinations; another patient with a history of firearm injury to the left thigh with multiple secondary complications, which required various reconstructive procedures; and the oldest patient with a history of total hip replacement. The main complaint of the four patients was thigh pain not caused by trauma and initial assessment radiographs of all of them showed signs of loosening of the prosthetic material, with septic etiology in two of the patients and aseptic etiology in the other two. Therefore, they were scheduled for revision surgery of prosthetic components. These patients recover functional status and resolved pain in the early post-operative period and during long-term follow-up. Only one of the patients, time after the surgical procedure, required removal of the osteosynthesis material due to persistent bone infectious process. CONCLUSION: Septic and aseptic loosening is one of the most common complications of proximal femur endoprosthesis, resulting in significant pain and functional decline in patients. We present a novel surgical technique that allows primary stabilization of the construct that allows early rehabilitation, improvement of functionality, and no signs of new loosening. Indian Orthopaedic Research Group 2023-10 2023-10 /pmc/articles/PMC10599359/ /pubmed/37885631 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3964 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 Unported, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms |
spellingShingle | Case Report Gaitán-Lee, Hernando Chavarro, Ingrid P Rincón, Mariana Piñeros Visbal, Nicolle L Leal, Efraím Proximal Femur Endoprosthesis Augmentation with Polymethylmethacrylate and Condylar Plate: A Case Series |
title | Proximal Femur Endoprosthesis Augmentation with Polymethylmethacrylate and Condylar Plate: A Case Series |
title_full | Proximal Femur Endoprosthesis Augmentation with Polymethylmethacrylate and Condylar Plate: A Case Series |
title_fullStr | Proximal Femur Endoprosthesis Augmentation with Polymethylmethacrylate and Condylar Plate: A Case Series |
title_full_unstemmed | Proximal Femur Endoprosthesis Augmentation with Polymethylmethacrylate and Condylar Plate: A Case Series |
title_short | Proximal Femur Endoprosthesis Augmentation with Polymethylmethacrylate and Condylar Plate: A Case Series |
title_sort | proximal femur endoprosthesis augmentation with polymethylmethacrylate and condylar plate: a case series |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599359/ https://www.ncbi.nlm.nih.gov/pubmed/37885631 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3964 |
work_keys_str_mv | AT gaitanleehernando proximalfemurendoprosthesisaugmentationwithpolymethylmethacrylateandcondylarplateacaseseries AT chavarroingridp proximalfemurendoprosthesisaugmentationwithpolymethylmethacrylateandcondylarplateacaseseries AT rinconmarianapineros proximalfemurendoprosthesisaugmentationwithpolymethylmethacrylateandcondylarplateacaseseries AT visbalnicollel proximalfemurendoprosthesisaugmentationwithpolymethylmethacrylateandcondylarplateacaseseries AT lealefraim proximalfemurendoprosthesisaugmentationwithpolymethylmethacrylateandcondylarplateacaseseries |