Cargando…
Unique Procedure to Remove Pedicle Screw without Compatible Instrumentation: Case Report and Review of Literature
INTRODUCTION: As the number of patients undergoing spine fixation has increased, the requirement for revision surgery has also increased. Difficulty faced while doing revision surgery is mostly in removing polyaxial pedicle screws, especially if we do not have the desired instrumentation. CASE REPOR...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599364/ https://www.ncbi.nlm.nih.gov/pubmed/37885656 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3922 |
_version_ | 1785125752922963968 |
---|---|
author | Singh, Jagdeep Gupta, Pranav Bahadur, Raj Kumar, Sameer |
author_facet | Singh, Jagdeep Gupta, Pranav Bahadur, Raj Kumar, Sameer |
author_sort | Singh, Jagdeep |
collection | PubMed |
description | INTRODUCTION: As the number of patients undergoing spine fixation has increased, the requirement for revision surgery has also increased. Difficulty faced while doing revision surgery is mostly in removing polyaxial pedicle screws, especially if we do not have the desired instrumentation. CASE REPORT: A 55-year-old patient previously operated for D12 fracture presented to us with implant failure due to backing out of pedicle screws. Compatible instrumentation to remove the implant was not available as even the cap screw could not be removed due to screwdriver mismatch. Hence, we had to design our own method to address the problem which we did successfully. At present, the patient is on our regular follow-up, is pain free, is able to walk without support, and has not reported any new complaints. CONCLUSION: Method used in our case simplifies and accelerates the screw removal process and provides guidance to any surgeon who faces a similar problem. |
format | Online Article Text |
id | pubmed-10599364 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Indian Orthopaedic Research Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-105993642023-10-26 Unique Procedure to Remove Pedicle Screw without Compatible Instrumentation: Case Report and Review of Literature Singh, Jagdeep Gupta, Pranav Bahadur, Raj Kumar, Sameer J Orthop Case Rep Case Report INTRODUCTION: As the number of patients undergoing spine fixation has increased, the requirement for revision surgery has also increased. Difficulty faced while doing revision surgery is mostly in removing polyaxial pedicle screws, especially if we do not have the desired instrumentation. CASE REPORT: A 55-year-old patient previously operated for D12 fracture presented to us with implant failure due to backing out of pedicle screws. Compatible instrumentation to remove the implant was not available as even the cap screw could not be removed due to screwdriver mismatch. Hence, we had to design our own method to address the problem which we did successfully. At present, the patient is on our regular follow-up, is pain free, is able to walk without support, and has not reported any new complaints. CONCLUSION: Method used in our case simplifies and accelerates the screw removal process and provides guidance to any surgeon who faces a similar problem. Indian Orthopaedic Research Group 2023-10 2023-10 /pmc/articles/PMC10599364/ /pubmed/37885656 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3922 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 Unported, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms |
spellingShingle | Case Report Singh, Jagdeep Gupta, Pranav Bahadur, Raj Kumar, Sameer Unique Procedure to Remove Pedicle Screw without Compatible Instrumentation: Case Report and Review of Literature |
title | Unique Procedure to Remove Pedicle Screw without Compatible Instrumentation: Case Report and Review of Literature |
title_full | Unique Procedure to Remove Pedicle Screw without Compatible Instrumentation: Case Report and Review of Literature |
title_fullStr | Unique Procedure to Remove Pedicle Screw without Compatible Instrumentation: Case Report and Review of Literature |
title_full_unstemmed | Unique Procedure to Remove Pedicle Screw without Compatible Instrumentation: Case Report and Review of Literature |
title_short | Unique Procedure to Remove Pedicle Screw without Compatible Instrumentation: Case Report and Review of Literature |
title_sort | unique procedure to remove pedicle screw without compatible instrumentation: case report and review of literature |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599364/ https://www.ncbi.nlm.nih.gov/pubmed/37885656 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3922 |
work_keys_str_mv | AT singhjagdeep uniqueproceduretoremovepediclescrewwithoutcompatibleinstrumentationcasereportandreviewofliterature AT guptapranav uniqueproceduretoremovepediclescrewwithoutcompatibleinstrumentationcasereportandreviewofliterature AT bahadurraj uniqueproceduretoremovepediclescrewwithoutcompatibleinstrumentationcasereportandreviewofliterature AT kumarsameer uniqueproceduretoremovepediclescrewwithoutcompatibleinstrumentationcasereportandreviewofliterature |