Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report
INTRODUCTION: The evolution of prosthesis design has increased the frequency of RTSA procedures across various indications. This rise in surgeries has also led to a growing number of associated complications. This case report highlights an unusual occurrence: a mechanical failure of a RTSA at the hu...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599366/ https://www.ncbi.nlm.nih.gov/pubmed/37885639 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3956 |
_version_ | 1785125753390628864 |
---|---|
author | Kaymakoglu, Mehmet Aral, Furkan Huri, Gazi |
author_facet | Kaymakoglu, Mehmet Aral, Furkan Huri, Gazi |
author_sort | Kaymakoglu, Mehmet |
collection | PubMed |
description | INTRODUCTION: The evolution of prosthesis design has increased the frequency of RTSA procedures across various indications. This rise in surgeries has also led to a growing number of associated complications. This case report highlights an unusual occurrence: a mechanical failure of a RTSA at the humeral stem tray. CASE REPORT: A 55-year-old male patient was admitted to our hospital with a sharp pain after 2 years of his initial reverse total shoulder arthroplasty (RTSA) surgery. A broken humeral stem of the RTSA was diagnosed on the plain radiography and the patient underwent a one-stage revision. Further complications have not arisen during his follow-up to date and the patient has a nearly full range of motion. CONCLUSION: Although a humeral stem tray failure is a rarely seen complication for shoulder arthroplasty, surgeons who have used this model prosthesis should be aware that they may encounter such a complication. |
format | Online Article Text |
id | pubmed-10599366 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Indian Orthopaedic Research Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-105993662023-10-26 Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report Kaymakoglu, Mehmet Aral, Furkan Huri, Gazi J Orthop Case Rep Case Report INTRODUCTION: The evolution of prosthesis design has increased the frequency of RTSA procedures across various indications. This rise in surgeries has also led to a growing number of associated complications. This case report highlights an unusual occurrence: a mechanical failure of a RTSA at the humeral stem tray. CASE REPORT: A 55-year-old male patient was admitted to our hospital with a sharp pain after 2 years of his initial reverse total shoulder arthroplasty (RTSA) surgery. A broken humeral stem of the RTSA was diagnosed on the plain radiography and the patient underwent a one-stage revision. Further complications have not arisen during his follow-up to date and the patient has a nearly full range of motion. CONCLUSION: Although a humeral stem tray failure is a rarely seen complication for shoulder arthroplasty, surgeons who have used this model prosthesis should be aware that they may encounter such a complication. Indian Orthopaedic Research Group 2023-10 2023-10 /pmc/articles/PMC10599366/ /pubmed/37885639 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3956 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 Unported, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms |
spellingShingle | Case Report Kaymakoglu, Mehmet Aral, Furkan Huri, Gazi Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report |
title | Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report |
title_full | Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report |
title_fullStr | Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report |
title_full_unstemmed | Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report |
title_short | Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report |
title_sort | failure of a reverse total shoulder arthroplasty with a broken humeral stem tray: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599366/ https://www.ncbi.nlm.nih.gov/pubmed/37885639 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3956 |
work_keys_str_mv | AT kaymakoglumehmet failureofareversetotalshoulderarthroplastywithabrokenhumeralstemtrayacasereport AT aralfurkan failureofareversetotalshoulderarthroplastywithabrokenhumeralstemtrayacasereport AT hurigazi failureofareversetotalshoulderarthroplastywithabrokenhumeralstemtrayacasereport |