Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report

INTRODUCTION: The evolution of prosthesis design has increased the frequency of RTSA procedures across various indications. This rise in surgeries has also led to a growing number of associated complications. This case report highlights an unusual occurrence: a mechanical failure of a RTSA at the hu...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaymakoglu, Mehmet, Aral, Furkan, Huri, Gazi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599366/
https://www.ncbi.nlm.nih.gov/pubmed/37885639
http://dx.doi.org/10.13107/jocr.2023.v13.i10.3956
_version_ 1785125753390628864
author Kaymakoglu, Mehmet
Aral, Furkan
Huri, Gazi
author_facet Kaymakoglu, Mehmet
Aral, Furkan
Huri, Gazi
author_sort Kaymakoglu, Mehmet
collection PubMed
description INTRODUCTION: The evolution of prosthesis design has increased the frequency of RTSA procedures across various indications. This rise in surgeries has also led to a growing number of associated complications. This case report highlights an unusual occurrence: a mechanical failure of a RTSA at the humeral stem tray. CASE REPORT: A 55-year-old male patient was admitted to our hospital with a sharp pain after 2 years of his initial reverse total shoulder arthroplasty (RTSA) surgery. A broken humeral stem of the RTSA was diagnosed on the plain radiography and the patient underwent a one-stage revision. Further complications have not arisen during his follow-up to date and the patient has a nearly full range of motion. CONCLUSION: Although a humeral stem tray failure is a rarely seen complication for shoulder arthroplasty, surgeons who have used this model prosthesis should be aware that they may encounter such a complication.
format Online
Article
Text
id pubmed-10599366
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-105993662023-10-26 Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report Kaymakoglu, Mehmet Aral, Furkan Huri, Gazi J Orthop Case Rep Case Report INTRODUCTION: The evolution of prosthesis design has increased the frequency of RTSA procedures across various indications. This rise in surgeries has also led to a growing number of associated complications. This case report highlights an unusual occurrence: a mechanical failure of a RTSA at the humeral stem tray. CASE REPORT: A 55-year-old male patient was admitted to our hospital with a sharp pain after 2 years of his initial reverse total shoulder arthroplasty (RTSA) surgery. A broken humeral stem of the RTSA was diagnosed on the plain radiography and the patient underwent a one-stage revision. Further complications have not arisen during his follow-up to date and the patient has a nearly full range of motion. CONCLUSION: Although a humeral stem tray failure is a rarely seen complication for shoulder arthroplasty, surgeons who have used this model prosthesis should be aware that they may encounter such a complication. Indian Orthopaedic Research Group 2023-10 2023-10 /pmc/articles/PMC10599366/ /pubmed/37885639 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3956 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 Unported, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms
spellingShingle Case Report
Kaymakoglu, Mehmet
Aral, Furkan
Huri, Gazi
Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report
title Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report
title_full Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report
title_fullStr Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report
title_full_unstemmed Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report
title_short Failure of a Reverse Total Shoulder Arthroplasty with a Broken Humeral Stem Tray: A Case Report
title_sort failure of a reverse total shoulder arthroplasty with a broken humeral stem tray: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599366/
https://www.ncbi.nlm.nih.gov/pubmed/37885639
http://dx.doi.org/10.13107/jocr.2023.v13.i10.3956
work_keys_str_mv AT kaymakoglumehmet failureofareversetotalshoulderarthroplastywithabrokenhumeralstemtrayacasereport
AT aralfurkan failureofareversetotalshoulderarthroplastywithabrokenhumeralstemtrayacasereport
AT hurigazi failureofareversetotalshoulderarthroplastywithabrokenhumeralstemtrayacasereport