Cargando…

Windshield Wiper Effect in Human Bone-Peri-Implant Benign Diaphyseal Expansile Lesion with Humerus Shaft Fracture Non-Union with Implant in situ - Case Report

INTRODUCTION: Humerus shaft fractures account for 3% of all adult fractures. Union rate after surgical management is around 84–97% with no difference between compression plating and intramedullary (IM) nailing. Non-union of humeral shaft fracture is not unusual complication of both conservative and...

Descripción completa

Detalles Bibliográficos
Autores principales: Thakkar, Yash N, Bava, S S, Phunde, Rajendra, Soni, Harshil, Haider, Hunaid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599387/
https://www.ncbi.nlm.nih.gov/pubmed/37885635
http://dx.doi.org/10.13107/jocr.2023.v13.i10.3926
_version_ 1785125758507679744
author Thakkar, Yash N
Bava, S S
Phunde, Rajendra
Soni, Harshil
Haider, Hunaid
author_facet Thakkar, Yash N
Bava, S S
Phunde, Rajendra
Soni, Harshil
Haider, Hunaid
author_sort Thakkar, Yash N
collection PubMed
description INTRODUCTION: Humerus shaft fractures account for 3% of all adult fractures. Union rate after surgical management is around 84–97% with no difference between compression plating and intramedullary (IM) nailing. Non-union of humeral shaft fracture is not unusual complication of both conservative and operative treatment. IM nailing has been known to have several benefits from its relative stability with minimal soft-tissue dissection but with drawbacks such as less perfect reduction with higher risk of distraction, inability to take down interpositional tissue, risk of radial nerve injury and technical difficulty to pass guide wire and locking of nail. Many methods have been described for nonunion of humeral fracture with good results. However, treatment of a long-standing nonunion of the humerus with bone defect is challenging, as it may be complicated by broken implants. Very less research documented for long standing nonunion of humeral bone with diaphyseal bone defect. CASE REPORT: We report a case report of middle-aged female who suffered a closed traumatic humeral shaft fracture which was managed with open reduction and fixation with IM nailing with some distraction and distal locking screw missing the nail making it an unstable construct traditionally called Wind shield, wiper effect was noticed in this patient and was the cause of nonunion in this case at some other institute 5 years back lending up in to nonunion with diaphyseal bone defect showing peri-implant expansile benign lesion treated at our institute with implant removal, excision of lytic lesion, and stabilized with extra articular distal humerus locking plate after strut fibular auto bone grafting . CONCLUSION: Humerus shaft non-union in a middle-aged patient is heterogeneous entity and has to be managed after ruling out neoplastic (metastasis) as well as infective etiology, and locking plate is the gold standard for its management along with strut grafting being osteoporotic bone with some bony defect.
format Online
Article
Text
id pubmed-10599387
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-105993872023-10-26 Windshield Wiper Effect in Human Bone-Peri-Implant Benign Diaphyseal Expansile Lesion with Humerus Shaft Fracture Non-Union with Implant in situ - Case Report Thakkar, Yash N Bava, S S Phunde, Rajendra Soni, Harshil Haider, Hunaid J Orthop Case Rep Case Report INTRODUCTION: Humerus shaft fractures account for 3% of all adult fractures. Union rate after surgical management is around 84–97% with no difference between compression plating and intramedullary (IM) nailing. Non-union of humeral shaft fracture is not unusual complication of both conservative and operative treatment. IM nailing has been known to have several benefits from its relative stability with minimal soft-tissue dissection but with drawbacks such as less perfect reduction with higher risk of distraction, inability to take down interpositional tissue, risk of radial nerve injury and technical difficulty to pass guide wire and locking of nail. Many methods have been described for nonunion of humeral fracture with good results. However, treatment of a long-standing nonunion of the humerus with bone defect is challenging, as it may be complicated by broken implants. Very less research documented for long standing nonunion of humeral bone with diaphyseal bone defect. CASE REPORT: We report a case report of middle-aged female who suffered a closed traumatic humeral shaft fracture which was managed with open reduction and fixation with IM nailing with some distraction and distal locking screw missing the nail making it an unstable construct traditionally called Wind shield, wiper effect was noticed in this patient and was the cause of nonunion in this case at some other institute 5 years back lending up in to nonunion with diaphyseal bone defect showing peri-implant expansile benign lesion treated at our institute with implant removal, excision of lytic lesion, and stabilized with extra articular distal humerus locking plate after strut fibular auto bone grafting . CONCLUSION: Humerus shaft non-union in a middle-aged patient is heterogeneous entity and has to be managed after ruling out neoplastic (metastasis) as well as infective etiology, and locking plate is the gold standard for its management along with strut grafting being osteoporotic bone with some bony defect. Indian Orthopaedic Research Group 2023-10 2023-10 /pmc/articles/PMC10599387/ /pubmed/37885635 http://dx.doi.org/10.13107/jocr.2023.v13.i10.3926 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 Unported, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms
spellingShingle Case Report
Thakkar, Yash N
Bava, S S
Phunde, Rajendra
Soni, Harshil
Haider, Hunaid
Windshield Wiper Effect in Human Bone-Peri-Implant Benign Diaphyseal Expansile Lesion with Humerus Shaft Fracture Non-Union with Implant in situ - Case Report
title Windshield Wiper Effect in Human Bone-Peri-Implant Benign Diaphyseal Expansile Lesion with Humerus Shaft Fracture Non-Union with Implant in situ - Case Report
title_full Windshield Wiper Effect in Human Bone-Peri-Implant Benign Diaphyseal Expansile Lesion with Humerus Shaft Fracture Non-Union with Implant in situ - Case Report
title_fullStr Windshield Wiper Effect in Human Bone-Peri-Implant Benign Diaphyseal Expansile Lesion with Humerus Shaft Fracture Non-Union with Implant in situ - Case Report
title_full_unstemmed Windshield Wiper Effect in Human Bone-Peri-Implant Benign Diaphyseal Expansile Lesion with Humerus Shaft Fracture Non-Union with Implant in situ - Case Report
title_short Windshield Wiper Effect in Human Bone-Peri-Implant Benign Diaphyseal Expansile Lesion with Humerus Shaft Fracture Non-Union with Implant in situ - Case Report
title_sort windshield wiper effect in human bone-peri-implant benign diaphyseal expansile lesion with humerus shaft fracture non-union with implant in situ - case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599387/
https://www.ncbi.nlm.nih.gov/pubmed/37885635
http://dx.doi.org/10.13107/jocr.2023.v13.i10.3926
work_keys_str_mv AT thakkaryashn windshieldwipereffectinhumanboneperiimplantbenigndiaphysealexpansilelesionwithhumerusshaftfracturenonunionwithimplantinsitucasereport
AT bavass windshieldwipereffectinhumanboneperiimplantbenigndiaphysealexpansilelesionwithhumerusshaftfracturenonunionwithimplantinsitucasereport
AT phunderajendra windshieldwipereffectinhumanboneperiimplantbenigndiaphysealexpansilelesionwithhumerusshaftfracturenonunionwithimplantinsitucasereport
AT soniharshil windshieldwipereffectinhumanboneperiimplantbenigndiaphysealexpansilelesionwithhumerusshaftfracturenonunionwithimplantinsitucasereport
AT haiderhunaid windshieldwipereffectinhumanboneperiimplantbenigndiaphysealexpansilelesionwithhumerusshaftfracturenonunionwithimplantinsitucasereport