Retention of zirconia crown to oxidized titanium base abutment: Experimental research

STATEMENT OF PROBLEM: To separate the crown from the titanium base abutment, by using heat, caused oxidization of the titanium base abutment. The effect of this procedure on the retention of a crown is unclear. PURPOSE: To compare the resin bond strength and failure type between zirconia crowns and...

Descripción completa

Detalles Bibliográficos
Autores principales: Krongvanitchayakul, Rawikorn, Kunavisarut, Chatchai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599539/
https://www.ncbi.nlm.nih.gov/pubmed/37878631
http://dx.doi.org/10.1371/journal.pone.0287108
_version_ 1785125786069499904
author Krongvanitchayakul, Rawikorn
Kunavisarut, Chatchai
author_facet Krongvanitchayakul, Rawikorn
Kunavisarut, Chatchai
author_sort Krongvanitchayakul, Rawikorn
collection PubMed
description STATEMENT OF PROBLEM: To separate the crown from the titanium base abutment, by using heat, caused oxidization of the titanium base abutment. The effect of this procedure on the retention of a crown is unclear. PURPOSE: To compare the resin bond strength and failure type between zirconia crowns and titanium base abutments utilizing four different surface treatments. Surface roughness and morphology of each surface treatment were also investigated. MATERIAL AND METHODS: Forty titanium base abutments (Variobase®) were divided into four groups, 1. Control, 2. Air abraded, 3. Oxidized, and 4. Oxidized-air abraded. Oxidized and oxidized-air abraded groups were debonded from zirconia crowns using constant dry heat at 500 ˚C. For air abraded and oxidized-air abraded groups (after oxidization), the titanium base abutments were air abraded with Al(3)O(2). After cleaning, one specimen of each group was investigated under a non-contact profilometer (50x), then the same samples were investigated under SEM at 25,300,500,1000 magnification and EDS at 30kV of accelerated voltage. All specimens were then cemented (RelyX Ultimate). After aging, with thermocycling under 5C° to 55C°,120 seconds dwell time for 5,000 cycles, bond strength was tested and statistical differences were calculated with One-way ANOVA (p-value <0.05) follow by Tukey test. All separated crowns and titanium base abutments were investigated under a light microscope (20x), using fisher’s exact test for correlation of the failure types. RESULTS: There was a significant difference in the mean value of tensile bond strength among the control and test groups. Comparisons between control(237.6±46.3N) and oxidized(241.7±46.3N) showed statistically different values from air abraded(372.9±113.2N) when assembled using different surface treatments of the titanium-based abutments. (p-value<0.005) As for failure type, there were statistically significant differences between control versus air abraded, control versus oxidized-air abraded, oxidized versus air abraded, and oxidized versus oxidized-air abraded. (p-value<0.001) The titanium surface morphology shown from the profilometer and SEM was coordinated. Control (Ra 333.8nm) and oxidized (Ra 321.0nm) groups surfaces showed smooth, corrugated surfaces, meanwhile air abraded (Ra 476.0nm) and oxidized-air abraded (Ra 423.8nm) groups showed rough, rugged surfaces. CONCLUSION: Heat oxidization of titanium-based abutments did not adversely affect tensile bond strength or the failure mode and surface roughness between titanium base abutments and zirconia crowns. However, air abrasion of the titanium surface increased surface roughness and retentive strength. CLINICAL IMPLICATIONS: The titanium base abutments that were oxidized under heat treatment did not have an effect on crown retention. Thoroughly air abraded the titanium abutment prior to cementation can increase cement bond strength.
format Online
Article
Text
id pubmed-10599539
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-105995392023-10-26 Retention of zirconia crown to oxidized titanium base abutment: Experimental research Krongvanitchayakul, Rawikorn Kunavisarut, Chatchai PLoS One Research Article STATEMENT OF PROBLEM: To separate the crown from the titanium base abutment, by using heat, caused oxidization of the titanium base abutment. The effect of this procedure on the retention of a crown is unclear. PURPOSE: To compare the resin bond strength and failure type between zirconia crowns and titanium base abutments utilizing four different surface treatments. Surface roughness and morphology of each surface treatment were also investigated. MATERIAL AND METHODS: Forty titanium base abutments (Variobase®) were divided into four groups, 1. Control, 2. Air abraded, 3. Oxidized, and 4. Oxidized-air abraded. Oxidized and oxidized-air abraded groups were debonded from zirconia crowns using constant dry heat at 500 ˚C. For air abraded and oxidized-air abraded groups (after oxidization), the titanium base abutments were air abraded with Al(3)O(2). After cleaning, one specimen of each group was investigated under a non-contact profilometer (50x), then the same samples were investigated under SEM at 25,300,500,1000 magnification and EDS at 30kV of accelerated voltage. All specimens were then cemented (RelyX Ultimate). After aging, with thermocycling under 5C° to 55C°,120 seconds dwell time for 5,000 cycles, bond strength was tested and statistical differences were calculated with One-way ANOVA (p-value <0.05) follow by Tukey test. All separated crowns and titanium base abutments were investigated under a light microscope (20x), using fisher’s exact test for correlation of the failure types. RESULTS: There was a significant difference in the mean value of tensile bond strength among the control and test groups. Comparisons between control(237.6±46.3N) and oxidized(241.7±46.3N) showed statistically different values from air abraded(372.9±113.2N) when assembled using different surface treatments of the titanium-based abutments. (p-value<0.005) As for failure type, there were statistically significant differences between control versus air abraded, control versus oxidized-air abraded, oxidized versus air abraded, and oxidized versus oxidized-air abraded. (p-value<0.001) The titanium surface morphology shown from the profilometer and SEM was coordinated. Control (Ra 333.8nm) and oxidized (Ra 321.0nm) groups surfaces showed smooth, corrugated surfaces, meanwhile air abraded (Ra 476.0nm) and oxidized-air abraded (Ra 423.8nm) groups showed rough, rugged surfaces. CONCLUSION: Heat oxidization of titanium-based abutments did not adversely affect tensile bond strength or the failure mode and surface roughness between titanium base abutments and zirconia crowns. However, air abrasion of the titanium surface increased surface roughness and retentive strength. CLINICAL IMPLICATIONS: The titanium base abutments that were oxidized under heat treatment did not have an effect on crown retention. Thoroughly air abraded the titanium abutment prior to cementation can increase cement bond strength. Public Library of Science 2023-10-25 /pmc/articles/PMC10599539/ /pubmed/37878631 http://dx.doi.org/10.1371/journal.pone.0287108 Text en © 2023 Krongvanitchayakul, Kunavisarut https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Krongvanitchayakul, Rawikorn
Kunavisarut, Chatchai
Retention of zirconia crown to oxidized titanium base abutment: Experimental research
title Retention of zirconia crown to oxidized titanium base abutment: Experimental research
title_full Retention of zirconia crown to oxidized titanium base abutment: Experimental research
title_fullStr Retention of zirconia crown to oxidized titanium base abutment: Experimental research
title_full_unstemmed Retention of zirconia crown to oxidized titanium base abutment: Experimental research
title_short Retention of zirconia crown to oxidized titanium base abutment: Experimental research
title_sort retention of zirconia crown to oxidized titanium base abutment: experimental research
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599539/
https://www.ncbi.nlm.nih.gov/pubmed/37878631
http://dx.doi.org/10.1371/journal.pone.0287108
work_keys_str_mv AT krongvanitchayakulrawikorn retentionofzirconiacrowntooxidizedtitaniumbaseabutmentexperimentalresearch
AT kunavisarutchatchai retentionofzirconiacrowntooxidizedtitaniumbaseabutmentexperimentalresearch