Cargando…

Reliability and Measurement Error of the Qualitative Analysis of Single Leg Loading (QASLS) Tool For Unilateral Tasks

BACKGROUND: Movement quality assessment is popular within clinical and sporting practice, due to the contribution diminished or suboptimal movement quality is believed to have on musculoskeletal (MSK) injury risk. Various movement quality assessments exist, many are limited to bilateral or jumping m...

Descripción completa

Detalles Bibliográficos
Autores principales: Parry, Gemma N, Herrington, Lee C, Munro, Allan G
Formato: Online Artículo Texto
Lenguaje:English
Publicado: NASMI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599652/
https://www.ncbi.nlm.nih.gov/pubmed/37885771
http://dx.doi.org/10.26603/001c.88007
_version_ 1785125810996248576
author Parry, Gemma N
Herrington, Lee C
Munro, Allan G
author_facet Parry, Gemma N
Herrington, Lee C
Munro, Allan G
author_sort Parry, Gemma N
collection PubMed
description BACKGROUND: Movement quality assessment is popular within clinical and sporting practice, due to the contribution diminished or suboptimal movement quality is believed to have on musculoskeletal (MSK) injury risk. Various movement quality assessments exist, many are limited to bilateral or jumping movements evaluation. Qualitative analysis of single leg loading (QASLS) is a new clinical assessment tool for unilateral tasks that utilizes a dichotomous scoring system of ten questions relating to the segmental body regions of the trunk, lower and upper limb. PURPOSE: To determine the intra and inter-rater, within- and between-session reliability of the QASLS tool during two unilateral movement tasks, and provide insight to measurement error and smallest detectable difference (SDD). STUDY DESIGN: Reliability Study METHODS: Fifteen healthy females (mean age 19 years SD2; height 167 cm, +/- 6; weight 56 kg, +/- 6) completed two unilateral tasks, single leg squat (SLS) and single leg landing (SLL), within session data collection occurred on the same day, with between session data collection occurring seven days later. Tasks were scored with the QASLS tool via video playback. Intra-Class correlation coefficients (ICC(k,3)) were used to measure within and between session reliability, and Kappa coefficients and percentage of exact agreement (PEA%) were used to determine intra and inter-rater reliability. Standard error of measurement (SEM) and the SDD for the compound score of each limb was calculated. RESULTS: Within session reliability of QASLS scores was good (ICC = 0.82-0.86) for SLS and moderate (ICC = 0.67-0.87) for SLL. Between session reliability was moderate (ICC = 0.69-0.87) for SLS and excellent (ICC = 0.92-0.93) for SLL. SEM was less than 1 point, and SDD for compound score ranging from 1.0-2.5 points. Intra-rater agreement of compound QASLS score was near perfect (k = 0.85-100; PEA% 90-100%) and agreement of individual components was substantial- near perfect (k = 0.13-0.74; PEA% 78-100%). Inter-rater agreement for compound QASLS scores ranged from non-substantial (k = 0.13-0.74; PEA% 43.3-90%) for SLS and non-slight (k =0.03-0.17; PEA% 43.3-60%) for SLL. CONCLUSIONS: The QASLS movement analysis tool can be used to analyze movement quality during two unilateral loading tasks with moderate to excellent within and between session reliability. PEA% was acceptable for inter-rater agreement, however rater education training is recommended to develop more acceptable levels of reliability. LEVEL OF EVIDENCE: 3
format Online
Article
Text
id pubmed-10599652
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher NASMI
record_format MEDLINE/PubMed
spelling pubmed-105996522023-10-26 Reliability and Measurement Error of the Qualitative Analysis of Single Leg Loading (QASLS) Tool For Unilateral Tasks Parry, Gemma N Herrington, Lee C Munro, Allan G Int J Sports Phys Ther Original Research BACKGROUND: Movement quality assessment is popular within clinical and sporting practice, due to the contribution diminished or suboptimal movement quality is believed to have on musculoskeletal (MSK) injury risk. Various movement quality assessments exist, many are limited to bilateral or jumping movements evaluation. Qualitative analysis of single leg loading (QASLS) is a new clinical assessment tool for unilateral tasks that utilizes a dichotomous scoring system of ten questions relating to the segmental body regions of the trunk, lower and upper limb. PURPOSE: To determine the intra and inter-rater, within- and between-session reliability of the QASLS tool during two unilateral movement tasks, and provide insight to measurement error and smallest detectable difference (SDD). STUDY DESIGN: Reliability Study METHODS: Fifteen healthy females (mean age 19 years SD2; height 167 cm, +/- 6; weight 56 kg, +/- 6) completed two unilateral tasks, single leg squat (SLS) and single leg landing (SLL), within session data collection occurred on the same day, with between session data collection occurring seven days later. Tasks were scored with the QASLS tool via video playback. Intra-Class correlation coefficients (ICC(k,3)) were used to measure within and between session reliability, and Kappa coefficients and percentage of exact agreement (PEA%) were used to determine intra and inter-rater reliability. Standard error of measurement (SEM) and the SDD for the compound score of each limb was calculated. RESULTS: Within session reliability of QASLS scores was good (ICC = 0.82-0.86) for SLS and moderate (ICC = 0.67-0.87) for SLL. Between session reliability was moderate (ICC = 0.69-0.87) for SLS and excellent (ICC = 0.92-0.93) for SLL. SEM was less than 1 point, and SDD for compound score ranging from 1.0-2.5 points. Intra-rater agreement of compound QASLS score was near perfect (k = 0.85-100; PEA% 90-100%) and agreement of individual components was substantial- near perfect (k = 0.13-0.74; PEA% 78-100%). Inter-rater agreement for compound QASLS scores ranged from non-substantial (k = 0.13-0.74; PEA% 43.3-90%) for SLS and non-slight (k =0.03-0.17; PEA% 43.3-60%) for SLL. CONCLUSIONS: The QASLS movement analysis tool can be used to analyze movement quality during two unilateral loading tasks with moderate to excellent within and between session reliability. PEA% was acceptable for inter-rater agreement, however rater education training is recommended to develop more acceptable levels of reliability. LEVEL OF EVIDENCE: 3 NASMI 2023-10-01 /pmc/articles/PMC10599652/ /pubmed/37885771 http://dx.doi.org/10.26603/001c.88007 Text en https://creativecommons.org/licenses/by-nc/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (4.0) (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Original Research
Parry, Gemma N
Herrington, Lee C
Munro, Allan G
Reliability and Measurement Error of the Qualitative Analysis of Single Leg Loading (QASLS) Tool For Unilateral Tasks
title Reliability and Measurement Error of the Qualitative Analysis of Single Leg Loading (QASLS) Tool For Unilateral Tasks
title_full Reliability and Measurement Error of the Qualitative Analysis of Single Leg Loading (QASLS) Tool For Unilateral Tasks
title_fullStr Reliability and Measurement Error of the Qualitative Analysis of Single Leg Loading (QASLS) Tool For Unilateral Tasks
title_full_unstemmed Reliability and Measurement Error of the Qualitative Analysis of Single Leg Loading (QASLS) Tool For Unilateral Tasks
title_short Reliability and Measurement Error of the Qualitative Analysis of Single Leg Loading (QASLS) Tool For Unilateral Tasks
title_sort reliability and measurement error of the qualitative analysis of single leg loading (qasls) tool for unilateral tasks
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10599652/
https://www.ncbi.nlm.nih.gov/pubmed/37885771
http://dx.doi.org/10.26603/001c.88007
work_keys_str_mv AT parrygemman reliabilityandmeasurementerrorofthequalitativeanalysisofsinglelegloadingqaslstoolforunilateraltasks
AT herringtonleec reliabilityandmeasurementerrorofthequalitativeanalysisofsinglelegloadingqaslstoolforunilateraltasks
AT munroallang reliabilityandmeasurementerrorofthequalitativeanalysisofsinglelegloadingqaslstoolforunilateraltasks