Cargando…
The Cochlear Size Variations in Incomplete Partitions with Multiplanar Images on Pediatric Temporal Bone CT
OBJECTIVES: The purpose of the study was to evaluate cochlea dimensions by the multiplanar reconstruction of high-resolution computed tomography that could be useful in diagnosing incomplete partition (IP) malformations. METHODS: This study included 32 patients with 64 side cochleae diagnosed with I...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Med Bull Sisli Etfal Hosp
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10600602/ https://www.ncbi.nlm.nih.gov/pubmed/37900333 http://dx.doi.org/10.14744/SEMB.2023.65725 |
_version_ | 1785126021419237376 |
---|---|
author | Aksoy, Direnc Ozlem Meltem, Emine Karagoz, Yesim Ulusan, Melis Baykara Mahmutoglu, Ozdes Mahmutoglu, Abdullah Soydan |
author_facet | Aksoy, Direnc Ozlem Meltem, Emine Karagoz, Yesim Ulusan, Melis Baykara Mahmutoglu, Ozdes Mahmutoglu, Abdullah Soydan |
author_sort | Aksoy, Direnc Ozlem |
collection | PubMed |
description | OBJECTIVES: The purpose of the study was to evaluate cochlea dimensions by the multiplanar reconstruction of high-resolution computed tomography that could be useful in diagnosing incomplete partition (IP) malformations. METHODS: This study included 32 patients with 64 side cochleae diagnosed with IP defect and 38 cochleae as the control without any defect. Basal turn length (BL), cochlear height (CH), Mid-apical length (MAL), Mid-apical height, Cochlear length (A), and Cochlear width (B) were measured on reformat images. RESULTS: Twenty cochleae of these patients have been diagnosed with IP type I, 34 with IP type II, and 10 with IP type III. The MAL values are shorter than the control group in IP types I and III (p<0.001, p<0.001). BL values are shorter in IP type III cases (p<0.001). In IP II cases, BL and MAL values overlapped with the control group. CH did not differ significantly from the control group in any IP type. A and B values were significantly lower than the control group for IP I and III (p<0.01). There is a positive correlation between A and B values for all IP types (p<0.01). CONCLUSION: Quantitative data about differences in the size and shape of the cochlea in IP cases would help differentiate them from the normal cochlea. Since A and B values showed a positive correlation, it is suggested that A and B values can be used to estimate CDL for IP types. |
format | Online Article Text |
id | pubmed-10600602 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Med Bull Sisli Etfal Hosp |
record_format | MEDLINE/PubMed |
spelling | pubmed-106006022023-10-27 The Cochlear Size Variations in Incomplete Partitions with Multiplanar Images on Pediatric Temporal Bone CT Aksoy, Direnc Ozlem Meltem, Emine Karagoz, Yesim Ulusan, Melis Baykara Mahmutoglu, Ozdes Mahmutoglu, Abdullah Soydan Sisli Etfal Hastan Tip Bul Original Research OBJECTIVES: The purpose of the study was to evaluate cochlea dimensions by the multiplanar reconstruction of high-resolution computed tomography that could be useful in diagnosing incomplete partition (IP) malformations. METHODS: This study included 32 patients with 64 side cochleae diagnosed with IP defect and 38 cochleae as the control without any defect. Basal turn length (BL), cochlear height (CH), Mid-apical length (MAL), Mid-apical height, Cochlear length (A), and Cochlear width (B) were measured on reformat images. RESULTS: Twenty cochleae of these patients have been diagnosed with IP type I, 34 with IP type II, and 10 with IP type III. The MAL values are shorter than the control group in IP types I and III (p<0.001, p<0.001). BL values are shorter in IP type III cases (p<0.001). In IP II cases, BL and MAL values overlapped with the control group. CH did not differ significantly from the control group in any IP type. A and B values were significantly lower than the control group for IP I and III (p<0.01). There is a positive correlation between A and B values for all IP types (p<0.01). CONCLUSION: Quantitative data about differences in the size and shape of the cochlea in IP cases would help differentiate them from the normal cochlea. Since A and B values showed a positive correlation, it is suggested that A and B values can be used to estimate CDL for IP types. Med Bull Sisli Etfal Hosp 2023-09-29 /pmc/articles/PMC10600602/ /pubmed/37900333 http://dx.doi.org/10.14744/SEMB.2023.65725 Text en ©Copyright 2023 by The Medical Bulletin of Sisli Etfal Hospital https://creativecommons.org/licenses/by-nc/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0) (https://creativecommons.org/licenses/by-nc/4.0/) |
spellingShingle | Original Research Aksoy, Direnc Ozlem Meltem, Emine Karagoz, Yesim Ulusan, Melis Baykara Mahmutoglu, Ozdes Mahmutoglu, Abdullah Soydan The Cochlear Size Variations in Incomplete Partitions with Multiplanar Images on Pediatric Temporal Bone CT |
title | The Cochlear Size Variations in Incomplete Partitions with Multiplanar Images on Pediatric Temporal Bone CT |
title_full | The Cochlear Size Variations in Incomplete Partitions with Multiplanar Images on Pediatric Temporal Bone CT |
title_fullStr | The Cochlear Size Variations in Incomplete Partitions with Multiplanar Images on Pediatric Temporal Bone CT |
title_full_unstemmed | The Cochlear Size Variations in Incomplete Partitions with Multiplanar Images on Pediatric Temporal Bone CT |
title_short | The Cochlear Size Variations in Incomplete Partitions with Multiplanar Images on Pediatric Temporal Bone CT |
title_sort | cochlear size variations in incomplete partitions with multiplanar images on pediatric temporal bone ct |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10600602/ https://www.ncbi.nlm.nih.gov/pubmed/37900333 http://dx.doi.org/10.14744/SEMB.2023.65725 |
work_keys_str_mv | AT aksoydirencozlem thecochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT meltememine thecochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT karagozyesim thecochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT ulusanmelisbaykara thecochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT mahmutogluozdes thecochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT mahmutogluabdullahsoydan thecochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT aksoydirencozlem cochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT meltememine cochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT karagozyesim cochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT ulusanmelisbaykara cochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT mahmutogluozdes cochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect AT mahmutogluabdullahsoydan cochlearsizevariationsinincompletepartitionswithmultiplanarimagesonpediatrictemporalbonect |