Cargando…

Bimetallic Cu–Zn Zeolitic Imidazolate Frameworks as Peroxidase Mimics for the Detection of Hydrogen Peroxide: Electrochemical and Spectrophotometric Evaluation

[Image: see text] A copper incorporated zeolitic imidazolate framework-8 (ZIF-8) has been synthesized and demonstrated to be a potential material for a peroxidase mimic. The resultant bimetallic Cu–Zn incorporated MOF is used for the dual mode sensing of hydrogen peroxide by following electrochemica...

Descripción completa

Detalles Bibliográficos
Autores principales: Mechoor, Aswathi, Berchmans, Sheela, Venkatachalam, Ganesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10601070/
https://www.ncbi.nlm.nih.gov/pubmed/37901575
http://dx.doi.org/10.1021/acsomega.3c05535
_version_ 1785126117626085376
author Mechoor, Aswathi
Berchmans, Sheela
Venkatachalam, Ganesh
author_facet Mechoor, Aswathi
Berchmans, Sheela
Venkatachalam, Ganesh
author_sort Mechoor, Aswathi
collection PubMed
description [Image: see text] A copper incorporated zeolitic imidazolate framework-8 (ZIF-8) has been synthesized and demonstrated to be a potential material for a peroxidase mimic. The resultant bimetallic Cu–Zn incorporated MOF is used for the dual mode sensing of hydrogen peroxide by following electrochemical as well as spectrophotometric methods. Using 3,3′,5,5′-tetramethylbenzidine (TMB) as a chromogenic substrate, spectrophotometric studies are carried out, and the steady state kinetic parameters are determined for two different concentrations of Cu incorporated ZIF-8 (viz Cu@ZIF-8-1 and Cu@ZIF-8-2). It is found that both Cu@ZIF-8-1 and Cu@ZIF-8-2 exhibit more affinity toward the TMB substrate than the horseradish peroxidase (HRP) enzyme as indicated by the low K(m) values obtained for the substrate. Also, as the concentration of incorporated Cu increases, V(max) values are also found to be enhanced. Electrochemically, the Cu@ZIF-8 modified glassy carbon electrode (GCE) showed a good response for peroxide detection in the concentration range from 0.5 mM to 5 mM at a working potential of −0.25 V in PBS (pH 7.0) with a limit of detection (LOD) value of 0.46 mM and a sensitivity of 20.25 μA/mM. Further, the chromogenic substrate TMB is successfully immobilized on the electrode surface and subsequently used for the peroxide detection along with Cu@ZIF-8. Here, TMB acts as a mediator and shifted the working potential to 0.1 V in acetate buffer (pH 5.0) in the concentration range from 0.5 mM to 5 mM with an LOD value of 0.499 mM and a sensitivity of 0.097 μA/mM. Interestingly, the same electrode in PBS of pH 7.0 showed a response to peroxide at a working potential of −0.1 V in the concentration range from 0.5 mM to 5 mM with an LOD value of 0.143 mM and a sensitivity of 0.33 μA/mM. Moreover, the applicability of this material for peroxide sensing is evaluated using milk samples, and the proposed material is able to recover the peroxide present in milk. Thus, the bimetallic Cu–Zn MOF can be utilized for the dual mode sensing of peroxide and can be extended for various real time applications.
format Online
Article
Text
id pubmed-10601070
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-106010702023-10-27 Bimetallic Cu–Zn Zeolitic Imidazolate Frameworks as Peroxidase Mimics for the Detection of Hydrogen Peroxide: Electrochemical and Spectrophotometric Evaluation Mechoor, Aswathi Berchmans, Sheela Venkatachalam, Ganesh ACS Omega [Image: see text] A copper incorporated zeolitic imidazolate framework-8 (ZIF-8) has been synthesized and demonstrated to be a potential material for a peroxidase mimic. The resultant bimetallic Cu–Zn incorporated MOF is used for the dual mode sensing of hydrogen peroxide by following electrochemical as well as spectrophotometric methods. Using 3,3′,5,5′-tetramethylbenzidine (TMB) as a chromogenic substrate, spectrophotometric studies are carried out, and the steady state kinetic parameters are determined for two different concentrations of Cu incorporated ZIF-8 (viz Cu@ZIF-8-1 and Cu@ZIF-8-2). It is found that both Cu@ZIF-8-1 and Cu@ZIF-8-2 exhibit more affinity toward the TMB substrate than the horseradish peroxidase (HRP) enzyme as indicated by the low K(m) values obtained for the substrate. Also, as the concentration of incorporated Cu increases, V(max) values are also found to be enhanced. Electrochemically, the Cu@ZIF-8 modified glassy carbon electrode (GCE) showed a good response for peroxide detection in the concentration range from 0.5 mM to 5 mM at a working potential of −0.25 V in PBS (pH 7.0) with a limit of detection (LOD) value of 0.46 mM and a sensitivity of 20.25 μA/mM. Further, the chromogenic substrate TMB is successfully immobilized on the electrode surface and subsequently used for the peroxide detection along with Cu@ZIF-8. Here, TMB acts as a mediator and shifted the working potential to 0.1 V in acetate buffer (pH 5.0) in the concentration range from 0.5 mM to 5 mM with an LOD value of 0.499 mM and a sensitivity of 0.097 μA/mM. Interestingly, the same electrode in PBS of pH 7.0 showed a response to peroxide at a working potential of −0.1 V in the concentration range from 0.5 mM to 5 mM with an LOD value of 0.143 mM and a sensitivity of 0.33 μA/mM. Moreover, the applicability of this material for peroxide sensing is evaluated using milk samples, and the proposed material is able to recover the peroxide present in milk. Thus, the bimetallic Cu–Zn MOF can be utilized for the dual mode sensing of peroxide and can be extended for various real time applications. American Chemical Society 2023-10-15 /pmc/articles/PMC10601070/ /pubmed/37901575 http://dx.doi.org/10.1021/acsomega.3c05535 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Mechoor, Aswathi
Berchmans, Sheela
Venkatachalam, Ganesh
Bimetallic Cu–Zn Zeolitic Imidazolate Frameworks as Peroxidase Mimics for the Detection of Hydrogen Peroxide: Electrochemical and Spectrophotometric Evaluation
title Bimetallic Cu–Zn Zeolitic Imidazolate Frameworks as Peroxidase Mimics for the Detection of Hydrogen Peroxide: Electrochemical and Spectrophotometric Evaluation
title_full Bimetallic Cu–Zn Zeolitic Imidazolate Frameworks as Peroxidase Mimics for the Detection of Hydrogen Peroxide: Electrochemical and Spectrophotometric Evaluation
title_fullStr Bimetallic Cu–Zn Zeolitic Imidazolate Frameworks as Peroxidase Mimics for the Detection of Hydrogen Peroxide: Electrochemical and Spectrophotometric Evaluation
title_full_unstemmed Bimetallic Cu–Zn Zeolitic Imidazolate Frameworks as Peroxidase Mimics for the Detection of Hydrogen Peroxide: Electrochemical and Spectrophotometric Evaluation
title_short Bimetallic Cu–Zn Zeolitic Imidazolate Frameworks as Peroxidase Mimics for the Detection of Hydrogen Peroxide: Electrochemical and Spectrophotometric Evaluation
title_sort bimetallic cu–zn zeolitic imidazolate frameworks as peroxidase mimics for the detection of hydrogen peroxide: electrochemical and spectrophotometric evaluation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10601070/
https://www.ncbi.nlm.nih.gov/pubmed/37901575
http://dx.doi.org/10.1021/acsomega.3c05535
work_keys_str_mv AT mechooraswathi bimetalliccuznzeoliticimidazolateframeworksasperoxidasemimicsforthedetectionofhydrogenperoxideelectrochemicalandspectrophotometricevaluation
AT berchmanssheela bimetalliccuznzeoliticimidazolateframeworksasperoxidasemimicsforthedetectionofhydrogenperoxideelectrochemicalandspectrophotometricevaluation
AT venkatachalamganesh bimetalliccuznzeoliticimidazolateframeworksasperoxidasemimicsforthedetectionofhydrogenperoxideelectrochemicalandspectrophotometricevaluation