Cargando…

Large Area Kidney Imaging for Pre-transplant Evaluation using Real-Time Robotic Optical Coherence Tomography

Optical coherence tomography (OCT) is a high-resolution imaging modality that can be used to image microstructures of human kidneys. These images can be analyzed to evaluate the viability of the organ for transplantation. However, current OCT devices suffer from insufficient field-of-view, leading t...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Xihan, Moradi, Mousa, Ma, Xiaoyu, Tang, Qinggong, Levi, Moshe, Chen, Yu, Zhang, Haichong K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Journal Experts 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10602184/
https://www.ncbi.nlm.nih.gov/pubmed/37886456
http://dx.doi.org/10.21203/rs.3.rs-3385622/v1
_version_ 1785126344055586816
author Ma, Xihan
Moradi, Mousa
Ma, Xiaoyu
Tang, Qinggong
Levi, Moshe
Chen, Yu
Zhang, Haichong K.
author_facet Ma, Xihan
Moradi, Mousa
Ma, Xiaoyu
Tang, Qinggong
Levi, Moshe
Chen, Yu
Zhang, Haichong K.
author_sort Ma, Xihan
collection PubMed
description Optical coherence tomography (OCT) is a high-resolution imaging modality that can be used to image microstructures of human kidneys. These images can be analyzed to evaluate the viability of the organ for transplantation. However, current OCT devices suffer from insufficient field-of-view, leading to biased examination outcomes when only small portions of the kidney can be assessed. Here we present a robotic OCT system where an OCT probe is integrated with a robotic manipulator, enabling wider area spatially-resolved imaging. With the proposed system, it becomes possible to comprehensively scan the kidney surface and provide large area parameterization of the microstructures. We verified the probe tracking accuracy with a phantom as 0.0762±0.0727 mm and demonstrated its clinical feasibility by scanning ex vivo kidneys. The parametric map exhibits fine vasculatures beneath the kidney surface. Quantitative analysis on the proximal convoluted tubule from the ex vivo human kidney yields highly clinical-relevant information.
format Online
Article
Text
id pubmed-10602184
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Journal Experts
record_format MEDLINE/PubMed
spelling pubmed-106021842023-10-27 Large Area Kidney Imaging for Pre-transplant Evaluation using Real-Time Robotic Optical Coherence Tomography Ma, Xihan Moradi, Mousa Ma, Xiaoyu Tang, Qinggong Levi, Moshe Chen, Yu Zhang, Haichong K. Res Sq Article Optical coherence tomography (OCT) is a high-resolution imaging modality that can be used to image microstructures of human kidneys. These images can be analyzed to evaluate the viability of the organ for transplantation. However, current OCT devices suffer from insufficient field-of-view, leading to biased examination outcomes when only small portions of the kidney can be assessed. Here we present a robotic OCT system where an OCT probe is integrated with a robotic manipulator, enabling wider area spatially-resolved imaging. With the proposed system, it becomes possible to comprehensively scan the kidney surface and provide large area parameterization of the microstructures. We verified the probe tracking accuracy with a phantom as 0.0762±0.0727 mm and demonstrated its clinical feasibility by scanning ex vivo kidneys. The parametric map exhibits fine vasculatures beneath the kidney surface. Quantitative analysis on the proximal convoluted tubule from the ex vivo human kidney yields highly clinical-relevant information. American Journal Experts 2023-10-16 /pmc/articles/PMC10602184/ /pubmed/37886456 http://dx.doi.org/10.21203/rs.3.rs-3385622/v1 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/) , which allows reusers to distribute, remix, adapt, and build upon the material in any medium or format, so long as attribution is given to the creator. The license allows for commercial use.
spellingShingle Article
Ma, Xihan
Moradi, Mousa
Ma, Xiaoyu
Tang, Qinggong
Levi, Moshe
Chen, Yu
Zhang, Haichong K.
Large Area Kidney Imaging for Pre-transplant Evaluation using Real-Time Robotic Optical Coherence Tomography
title Large Area Kidney Imaging for Pre-transplant Evaluation using Real-Time Robotic Optical Coherence Tomography
title_full Large Area Kidney Imaging for Pre-transplant Evaluation using Real-Time Robotic Optical Coherence Tomography
title_fullStr Large Area Kidney Imaging for Pre-transplant Evaluation using Real-Time Robotic Optical Coherence Tomography
title_full_unstemmed Large Area Kidney Imaging for Pre-transplant Evaluation using Real-Time Robotic Optical Coherence Tomography
title_short Large Area Kidney Imaging for Pre-transplant Evaluation using Real-Time Robotic Optical Coherence Tomography
title_sort large area kidney imaging for pre-transplant evaluation using real-time robotic optical coherence tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10602184/
https://www.ncbi.nlm.nih.gov/pubmed/37886456
http://dx.doi.org/10.21203/rs.3.rs-3385622/v1
work_keys_str_mv AT maxihan largeareakidneyimagingforpretransplantevaluationusingrealtimeroboticopticalcoherencetomography
AT moradimousa largeareakidneyimagingforpretransplantevaluationusingrealtimeroboticopticalcoherencetomography
AT maxiaoyu largeareakidneyimagingforpretransplantevaluationusingrealtimeroboticopticalcoherencetomography
AT tangqinggong largeareakidneyimagingforpretransplantevaluationusingrealtimeroboticopticalcoherencetomography
AT levimoshe largeareakidneyimagingforpretransplantevaluationusingrealtimeroboticopticalcoherencetomography
AT chenyu largeareakidneyimagingforpretransplantevaluationusingrealtimeroboticopticalcoherencetomography
AT zhanghaichongk largeareakidneyimagingforpretransplantevaluationusingrealtimeroboticopticalcoherencetomography