Cargando…

Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images

PURPOSE: Segmentation and reconstruction of arterial blood vessels is a fundamental step in the translation of computational fluid dynamics (CFD) to the clinical practice. Four-dimensional flow magnetic resonance imaging (4D Flow-MRI) can provide detailed information of blood flow but processing thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Black, Scott MacDonald, Maclean, Craig, Barrientos, Pauline Hall, Ritos, Konstantinos, Kazakidi, Asimina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10602980/
https://www.ncbi.nlm.nih.gov/pubmed/37653353
http://dx.doi.org/10.1007/s13239-023-00679-x
_version_ 1785126502461865984
author Black, Scott MacDonald
Maclean, Craig
Barrientos, Pauline Hall
Ritos, Konstantinos
Kazakidi, Asimina
author_facet Black, Scott MacDonald
Maclean, Craig
Barrientos, Pauline Hall
Ritos, Konstantinos
Kazakidi, Asimina
author_sort Black, Scott MacDonald
collection PubMed
description PURPOSE: Segmentation and reconstruction of arterial blood vessels is a fundamental step in the translation of computational fluid dynamics (CFD) to the clinical practice. Four-dimensional flow magnetic resonance imaging (4D Flow-MRI) can provide detailed information of blood flow but processing this information to elucidate the underlying anatomical structures is challenging. In this study, we present a novel approach to create high-contrast anatomical images from retrospective 4D Flow-MRI data. METHODS: For healthy and clinical cases, the 3D instantaneous velocities at multiple cardiac time steps were superimposed directly onto the 4D Flow-MRI magnitude images and combined into a single composite frame. This new Composite Phase-Contrast Magnetic Resonance Angiogram (CPC-MRA) resulted in enhanced and uniform contrast within the lumen. These images were subsequently segmented and reconstructed to generate 3D arterial models for CFD. Using the time-dependent, 3D incompressible Reynolds-averaged Navier–Stokes equations, the transient aortic haemodynamics was computed within a rigid wall model of patient geometries. RESULTS: Validation of these models against the gold standard CT-based approach showed no statistically significant inter-modality difference regarding vessel radius or curvature (p > 0.05), and a similar Dice Similarity Coefficient and Hausdorff Distance. CFD-derived near-wall hemodynamics indicated a significant inter-modality difference (p > 0.05), though these absolute errors were small. When compared to the in vivo data, CFD-derived velocities were qualitatively similar. CONCLUSION: This proof-of-concept study demonstrated that functional 4D Flow-MRI information can be utilized to retrospectively generate anatomical information for CFD models in the absence of standard imaging datasets and intravenous contrast. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13239-023-00679-x.
format Online
Article
Text
id pubmed-10602980
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-106029802023-10-28 Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images Black, Scott MacDonald Maclean, Craig Barrientos, Pauline Hall Ritos, Konstantinos Kazakidi, Asimina Cardiovasc Eng Technol Original Article PURPOSE: Segmentation and reconstruction of arterial blood vessels is a fundamental step in the translation of computational fluid dynamics (CFD) to the clinical practice. Four-dimensional flow magnetic resonance imaging (4D Flow-MRI) can provide detailed information of blood flow but processing this information to elucidate the underlying anatomical structures is challenging. In this study, we present a novel approach to create high-contrast anatomical images from retrospective 4D Flow-MRI data. METHODS: For healthy and clinical cases, the 3D instantaneous velocities at multiple cardiac time steps were superimposed directly onto the 4D Flow-MRI magnitude images and combined into a single composite frame. This new Composite Phase-Contrast Magnetic Resonance Angiogram (CPC-MRA) resulted in enhanced and uniform contrast within the lumen. These images were subsequently segmented and reconstructed to generate 3D arterial models for CFD. Using the time-dependent, 3D incompressible Reynolds-averaged Navier–Stokes equations, the transient aortic haemodynamics was computed within a rigid wall model of patient geometries. RESULTS: Validation of these models against the gold standard CT-based approach showed no statistically significant inter-modality difference regarding vessel radius or curvature (p > 0.05), and a similar Dice Similarity Coefficient and Hausdorff Distance. CFD-derived near-wall hemodynamics indicated a significant inter-modality difference (p > 0.05), though these absolute errors were small. When compared to the in vivo data, CFD-derived velocities were qualitatively similar. CONCLUSION: This proof-of-concept study demonstrated that functional 4D Flow-MRI information can be utilized to retrospectively generate anatomical information for CFD models in the absence of standard imaging datasets and intravenous contrast. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13239-023-00679-x. Springer International Publishing 2023-08-31 2023 /pmc/articles/PMC10602980/ /pubmed/37653353 http://dx.doi.org/10.1007/s13239-023-00679-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Black, Scott MacDonald
Maclean, Craig
Barrientos, Pauline Hall
Ritos, Konstantinos
Kazakidi, Asimina
Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images
title Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images
title_full Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images
title_fullStr Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images
title_full_unstemmed Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images
title_short Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images
title_sort reconstruction and validation of arterial geometries for computational fluid dynamics using multiple temporal frames of 4d flow-mri magnitude images
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10602980/
https://www.ncbi.nlm.nih.gov/pubmed/37653353
http://dx.doi.org/10.1007/s13239-023-00679-x
work_keys_str_mv AT blackscottmacdonald reconstructionandvalidationofarterialgeometriesforcomputationalfluiddynamicsusingmultipletemporalframesof4dflowmrimagnitudeimages
AT macleancraig reconstructionandvalidationofarterialgeometriesforcomputationalfluiddynamicsusingmultipletemporalframesof4dflowmrimagnitudeimages
AT barrientospaulinehall reconstructionandvalidationofarterialgeometriesforcomputationalfluiddynamicsusingmultipletemporalframesof4dflowmrimagnitudeimages
AT ritoskonstantinos reconstructionandvalidationofarterialgeometriesforcomputationalfluiddynamicsusingmultipletemporalframesof4dflowmrimagnitudeimages
AT kazakidiasimina reconstructionandvalidationofarterialgeometriesforcomputationalfluiddynamicsusingmultipletemporalframesof4dflowmrimagnitudeimages