Cargando…

Subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the DIAMONDS trial

OBJECTIVES: To estimate the economic costs, health-related quality-of-life outcomes and cost-effectiveness of subthreshold micropulse laser (SML) versus standard laser (SL) for the treatment of diabetic macular oedema (DMO) with central retinal thickness (CRT) of <400µ. DESIGN: An economic evalua...

Descripción completa

Detalles Bibliográficos
Autores principales: Mistry, Hema, Maredza, Mandy, Campbell, Christina, Lois, Noemi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10603454/
https://www.ncbi.nlm.nih.gov/pubmed/37852765
http://dx.doi.org/10.1136/bmjopen-2022-067684
_version_ 1785126608812638208
author Mistry, Hema
Maredza, Mandy
Campbell, Christina
Lois, Noemi
author_facet Mistry, Hema
Maredza, Mandy
Campbell, Christina
Lois, Noemi
author_sort Mistry, Hema
collection PubMed
description OBJECTIVES: To estimate the economic costs, health-related quality-of-life outcomes and cost-effectiveness of subthreshold micropulse laser (SML) versus standard laser (SL) for the treatment of diabetic macular oedema (DMO) with central retinal thickness (CRT) of <400µ. DESIGN: An economic evaluation was conducted within a pragmatic, multicentre, randomised clinical trial, DIAbetic Macular Oedema aNd Diode Subthreshold. SETTING: 18 UK Hospital Eye Services. PARTICIPANTS: Adults with diabetes and centre involving DMO with CRT<400µ. INTERVENTIONS: Participants (n=266) were randomised 1:1 to receive SML or SL. METHODS: The base-case used an intention-to-treat approach conducted from a UK National Health Service (NHS) and personal social services (PSS) perspective. Costs (2019–2020 prices) were collected prospectively over the 2-year follow-up period. A bivariate regression of costs and quality-adjusted life-years (QALYs), with multiple imputation of missing data, was conducted to estimate the incremental cost per QALY gained and the incremental net monetary benefit of SML in comparison to SL. Sensitivity analyses explored uncertainty and heterogeneity in cost-effectiveness estimates. RESULTS: One participant in the SL arm withdrew consent for data to be used; data from the remaining 265 participants were included in analyses. Mean (SE) NHS and PSS costs over 24 months were £735.09 (£111.85) in the SML arm vs £1099.70 (£195.40) in the SL arm (p=0.107). Mean (SE) QALY estimates were 1.493 (0.024) vs 1.485 (0.020), respectively (p=0.780), giving an insignificant difference of 0.008 QALYs. The probability SML is cost-effective at a threshold of £20 000 per QALY was 76%. CONCLUSIONS: There were no statistically significant differences in EQ-5D-5L scores or costs between SML and SL. Given these findings and the fact that SML does not burn the retina, unlike SL and has equivalent efficacy to SL, it may be preferred for the treatment of people with DMO with CRT<400µ. TRIAL REGISTRATION NUMBERS: ISRCTN17742985; NCT03690050.
format Online
Article
Text
id pubmed-10603454
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-106034542023-10-28 Subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the DIAMONDS trial Mistry, Hema Maredza, Mandy Campbell, Christina Lois, Noemi BMJ Open Health Economics OBJECTIVES: To estimate the economic costs, health-related quality-of-life outcomes and cost-effectiveness of subthreshold micropulse laser (SML) versus standard laser (SL) for the treatment of diabetic macular oedema (DMO) with central retinal thickness (CRT) of <400µ. DESIGN: An economic evaluation was conducted within a pragmatic, multicentre, randomised clinical trial, DIAbetic Macular Oedema aNd Diode Subthreshold. SETTING: 18 UK Hospital Eye Services. PARTICIPANTS: Adults with diabetes and centre involving DMO with CRT<400µ. INTERVENTIONS: Participants (n=266) were randomised 1:1 to receive SML or SL. METHODS: The base-case used an intention-to-treat approach conducted from a UK National Health Service (NHS) and personal social services (PSS) perspective. Costs (2019–2020 prices) were collected prospectively over the 2-year follow-up period. A bivariate regression of costs and quality-adjusted life-years (QALYs), with multiple imputation of missing data, was conducted to estimate the incremental cost per QALY gained and the incremental net monetary benefit of SML in comparison to SL. Sensitivity analyses explored uncertainty and heterogeneity in cost-effectiveness estimates. RESULTS: One participant in the SL arm withdrew consent for data to be used; data from the remaining 265 participants were included in analyses. Mean (SE) NHS and PSS costs over 24 months were £735.09 (£111.85) in the SML arm vs £1099.70 (£195.40) in the SL arm (p=0.107). Mean (SE) QALY estimates were 1.493 (0.024) vs 1.485 (0.020), respectively (p=0.780), giving an insignificant difference of 0.008 QALYs. The probability SML is cost-effective at a threshold of £20 000 per QALY was 76%. CONCLUSIONS: There were no statistically significant differences in EQ-5D-5L scores or costs between SML and SL. Given these findings and the fact that SML does not burn the retina, unlike SL and has equivalent efficacy to SL, it may be preferred for the treatment of people with DMO with CRT<400µ. TRIAL REGISTRATION NUMBERS: ISRCTN17742985; NCT03690050. BMJ Publishing Group 2023-10-18 /pmc/articles/PMC10603454/ /pubmed/37852765 http://dx.doi.org/10.1136/bmjopen-2022-067684 Text en © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY. Published by BMJ. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution 4.0 Unported (CC BY 4.0) license, which permits others to copy, redistribute, remix, transform and build upon this work for any purpose, provided the original work is properly cited, a link to the licence is given, and indication of whether changes were made. See: https://creativecommons.org/licenses/by/4.0/.
spellingShingle Health Economics
Mistry, Hema
Maredza, Mandy
Campbell, Christina
Lois, Noemi
Subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the DIAMONDS trial
title Subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the DIAMONDS trial
title_full Subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the DIAMONDS trial
title_fullStr Subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the DIAMONDS trial
title_full_unstemmed Subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the DIAMONDS trial
title_short Subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the DIAMONDS trial
title_sort subthreshold micropulse laser versus standard laser for the treatment of central-involving diabetic macular oedema with central retinal thickness of <400µ: a cost-effectiveness analysis from the diamonds trial
topic Health Economics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10603454/
https://www.ncbi.nlm.nih.gov/pubmed/37852765
http://dx.doi.org/10.1136/bmjopen-2022-067684
work_keys_str_mv AT mistryhema subthresholdmicropulselaserversusstandardlaserforthetreatmentofcentralinvolvingdiabeticmacularoedemawithcentralretinalthicknessof400μacosteffectivenessanalysisfromthediamondstrial
AT maredzamandy subthresholdmicropulselaserversusstandardlaserforthetreatmentofcentralinvolvingdiabeticmacularoedemawithcentralretinalthicknessof400μacosteffectivenessanalysisfromthediamondstrial
AT campbellchristina subthresholdmicropulselaserversusstandardlaserforthetreatmentofcentralinvolvingdiabeticmacularoedemawithcentralretinalthicknessof400μacosteffectivenessanalysisfromthediamondstrial
AT loisnoemi subthresholdmicropulselaserversusstandardlaserforthetreatmentofcentralinvolvingdiabeticmacularoedemawithcentralretinalthicknessof400μacosteffectivenessanalysisfromthediamondstrial